Sun MicrosystemsメーカーSG-XPCIE20FC-NEM-Zの使用説明書/サービス説明書
ページ先へ移動 of 68
Sun Microsystems, Inc. www .sun.com Submit comments about this document at: http://www.sun.com/hwdocs/feedback Sun StorageT ek ™ 4 Gb FC NEM 20-P or t Host Bus Adapter User’ s Guide F or HBA Model SG-XPCIE20FC-NEM-Z P ar t No .
Please Recycle Copyright 2008 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved. Sun Microsystems, Inc.
iii Contents Preface xi 1. Network Express Module Overview 1 NEM Features and Specifications 1 ID Chip Feature 3 Operating System Requirements 4 System Interoperability 4 Host Platform Support 5 Storage System Support 5 Fibre Channel Switch Support 6 2.
iv Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008 Using the ILOM W eb Interface 16 Using the ILOM CLI 17 ▼ T o V erify NEM Status 17 Replacing a NEM 19 ▼ T o Install the ID Chip Patch 19 ▼ T o Remove a NEM 19 ▼ T o Replace the ID Chip 20 3.
Contents v Declaration of Conformity 33 Safety Agency Compliance Statement 35 Regulatory Compliance Statements 47 Index 51.
vi Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008.
vii Figur es FIGURE 2-1 NEM Ejector Levers 9 FIGURE 2-2 Inserting the NEM Into the Chassis 10 FIGURE 2-3 Connecting the Optical Cables 12 FIGURE 2-4 Port Level LEDs 13 FIGURE 2-5 LEDs, Attention and L.
viii Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008.
ix T ables TABLE 1-1 NEM Features and Specifications 2 TABLE 1-2 Supported Operating System Versions 4 TABLE 1-3 Platform and Operating System Support 5 TABLE 2-1 Optical Cable Specifications 11 TABLE.
x Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008.
xi Pr eface This guide describes how to install and remove the Sun StorageT ek™ 4 Gb Fibre Channel (FC) Network Express Module (NEM) Host Bus Adapter (HBA), 20-port pass-through RoHS 5 compliant module.
xii Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008 Using UNIX Commands This document might not contain information about basic UNIX ® commands and procedur es such as shutting down the system, booting the system, and configuring devices.
Preface xiii T ypographic Conventions Related Documentation The documents listed are available at: http://www.sun.com/documentation/ T ypeface * * The settings on your browser might differ from these settings. Meaning Examples AaBbCc123 The names of commands, files, and directories; on-scr een computer output Edit your .
xiv Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008 Documentation, Support, and T raining Thir d-Party W eb Sites Sun is not responsible for the availability of third-party web sites mentioned in this document.
Preface xv Service Contact Information If you need help installing or using this product, call 1-800-USA-4SUN, or go to: http://www.sun.com/service/contacting/.
xvi Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008.
1 CHAPTER 1 Network Expr ess Module Overview This chapter provides a basic overview of the Sun StorageT ek™ 4 Gb Fibre Channel (FC) Network Express Module (NEM) Host Bus Adapter (HBA). This chapter also describes the various operating systems, host platforms, storage, and infrastructure configurations that support the NEM.
2 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008 T wenty SFP fiber -optic transceivers are included with each NEM. Y ou can order additional NEMs and SFP transceivers from Sun Microsystems using the following part numbers: See T ABLE 1-1 for a list of the NEM’s featur es.
Chapter 1 Network Express Module Over view 3 ID Chip Featur e The 20-port NEM has an ID chip on it that contains an Electrically Erasable Read Only Memory (EEPROM). This EEPROM stores the worldwide names (WWNs) for each of the ten HBAs and 20 FC ports on the NEM.
4 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008 ■ W indows: www- dl.emulex.com/support/windows/storport/130a9/manual.
Chapter 1 Network Express Module Over view 5 ■ “Fibre Channel Switch Support” on page 6 Host Platform Support The NEM is supported by the platforms and operating systems (OSs) listed in T ABLE 1-3 . Y ou can install the NEM in an available NEM slot of the Sun Blade 8000 Chassis or Sun Blade 8000 P chassis.
6 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008 ■ Sun StorEdge L5500, L8500 tape libraries Fibr e Channel Switch Support The NEM is supported with the followin.
7 CHAPTER 2 Har dware Installation and Removal This chapter describes the tasks requir ed to install and remove the NEM when the Sun Blade 8000 Modular System is in a power ed-on state.
8 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008 Observing ESD and Handling Pr ecautions Caution – Damage to the NEM can occur as the result of careless handling or electrostatic dischar ge (ESD). Always handle the NEM with care to avoid damage to electrostatic sensitive components.
Chapter 2 Hardware Installation and Removal 9 ▼ T o Install the NEM 1. Attach an antistatic strap (refer to “Observing ESD and Handling Precautions” on page 8 ). 2. Refer to your system installation or service manual to determine an appropriate slot in which to install the NEM.
10 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008 FIGURE 2-1 NEM Ejector Levers 6. Align the NEM with the chassis guidance system and slide the NEM into its slot (see FIGURE 2-2 ). Ensure that the NEM engages with the system chassis guidance system.
Chapter 2 Hardware Installation and Removal 11 FIGURE 2-2 Inserting the NEM Into the Chassis 7. Push the ejector levers toward each other and close the levers to secure the NEM in its slot. After you physically install the NEM in its slot, the Chassis Monitoring Module (CMM) will automatically detect the presence of the NEM.
12 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008 ▼ T o Connect the Optical Cables Note – The NEM does not allow normal data transmission on an optical link unless it is connected to another similar or compatible Fibr e Channel (FC) product (that is, multimode to multimode).
Chapter 2 Hardware Installation and Removal 13 FIGURE 2-3 Connecting the Optical Cables 2. Connect the other end of each cable to a FC device. After the optical cables are connected to the NEM, pr oceed to “Configuring the NEM For Hot-Plug Operation” on page 14 .
14 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008 FIGURE 2-4 Port Level LEDs T ABLE 2-2 summarizes port LED indicator combinations.
Chapter 2 Hardware Installation and Removal 15 Conf iguring the NEM For Hot-Plug Operation T o insert a NEM into the chassis while the system is running, you need to: 1.
16 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008 4. V erify that the selected NEM has returned the expected feedback. See “T o V erify NEM Status” on page 17 . Using the ILOM Command-Line Interface 1. Log in to the ILOM CLI of the active Chassis Monitoring Module.
Chapter 2 Hardware Installation and Removal 17 c. If all blades that you expect to be connected show a Connected link status, go to Step 4 . Otherwise, if a blade that you expect to be connected has a link status of Not connected , perform Step a - Step b again until its link status is Connected .
18 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008 4. V erify that the selected NEM has returned the expected feedback. See “T o V erify NEM Status” on page 17 . Using the ILOM CLI 1. Log in to the ILOM CLI of the active Chassis Monitoring Module.
Chapter 2 Hardware Installation and Removal 19 ■ Ready to Remove status shows Not Ready in the ILOM interfaces. FIGURE 2-5 LEDs, Attention and Locator Buttons The Attention button enables you to activate (if inserting) or prepare to r emove (if removing) a NEM during a hot-plug operation.
20 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008 Replacing a NEM If a NEM fails or if you choose to change the I/O configuration, you will need to replace it. Y ou can remove and replace a NEM fr om a powered-on system using a hot-plug operation, as well as from a powered-of f system.
Chapter 2 Hardware Installation and Removal 21 b. Press the latch on both ejector levers inward at the same time. c. Swing out the ejector levers to their fully open position. d. Slide the NEM out of its slot. Support the weight of the NEM with one hand at the bottom of the NEM.
22 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008 a. Position the notched side of the ID chip to the left. b. Place the ID chip directly over the connector . c. Press down easily to seat the ID chip to the connector .
23 CHAPTER 3 HBA Softwar e Installation After you have completed the hardwar e installation, follow the instructions listed in this chapter for your operating system to install the HBA driver and any other utilities requir ed for your installation.
24 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008 ■ Self-test ■ Loopback tests ■ External ■ Internal, single-bit ■ Internal, 10-bit ■ Mailbox Driver S.
Chapter 3 HBA Software Installation 25 2. Run Y aST online. Y ou will be notified that the 8.0.16.27 is being installed. Note – If you are running on a 2.6.5-7.244 kernel, you must install the Emulex 8.0.16.27 driver manually instead of updating using Y aST .
26 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008 3. Follow the instructions in the README f ile to build and install the 8.0.16.27 driver . Driver Softwar e for W indows 2003 OS The HBA driver for W indows 2003 OS is available for download at the Emulex support site for Sun Microsystems.
Chapter 3 HBA Software Installation 27 ■ Enable or disable the system BIOS ■ Run diagnostic tests on HBAs ■ Manage out-of-band HBAs ■ Manage local and in-band remote HBAs See the Linux or W indows OS Emulex user manual for more information about using the HBAnywhere and lputil utilities.
28 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008.
29 CHAPTER 4 Release Notes This chapter contains the latest supplementary information for the preceding chapters in this guide. It contains the following topics: ■ Using the NEM W ith Sun StorEdge 3.
30 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008 Solaris OS-Specif ic Issues The following known issues are r elated to installing, configuring, or operating the NEM with the Solaris 10 OS.
31 APPENDIX A Declaration of Conformity , Regulatory Compliance, and Safety Statements This appendix contains the following information that applies to the Sun StorageT ek 4 Gb FC NEM 20-Port HBA: ■.
32 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008.
33 << Declaration of Conformity Compliance Model Number: 375-3385-XX Product Family Name: Sun StorageT ek 4 Gb FC NEM HBA EMC USA - FCC Class A This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This equipment may not cause harmful interference.
34 Sun StorageTek 4 Gb FC NEM 20-Port Host Bus Adapter User’s Guide • February 2008.
35 Safety Agency Compliance Statement Read this section before beginning any procedure. The following text provides safety precautions to follow when installing a Sun Microsystems product.
36 Sun StorageT ek 4 Gb FC NEM 20-Port Host Bus Adapter User’ s Guide • F ebr uar y 2008 Power Cord Connection Caution – Sun products ar e designed to work with power systems having a grounded neutral (grounded r eturn for DC-power ed products).
Safety Agency Compliance Statement 37 Rack System Warning The following warnings apply to Racks and Rack Mounted systems. Caution – For safety , equipment should always be loaded from the bottom up. That is, install the equipment that will be mounted in the lowest part of the rack first, then the next higher systems, etc.
38 Sun StorageT ek 4 Gb FC NEM 20-Port Host Bus Adapter User’ s Guide • F ebr uar y 2008 Symboles Vous trouverez ci-dessous la signification des différents symboles utilisés: Attention – Vous risquez d'endommager le matériel ou de vous blesser .
Safety Agency Compliance Statement 39 Attention – T ous les cordons d'alimentation ne présentent pas les mêmes caractéristiques électriques. Les cordons d'alimentation à usage domestique ne sont pas protégés contr e les surtensions et ne sont pas conçus pour être utilisés avec des ordinateurs.
40 Sun StorageT ek 4 Gb FC NEM 20-Port Host Bus Adapter User’ s Guide • F ebr uar y 2008 Attention – Afin d'éviter que le rack ne penche pendant l'installation du matériel, tirez la barre anti-basculement du rack.
Safety Agency Compliance Statement 41 Je nach Netzschaltertyp an Ihrem Gerät kann eines der folgenden Symbole verwendet werden: Ein – V ersor gt das System mit W echselstrom. Aus– Unterbricht die W echselstromzufuhr zum Gerät. Wartezustand – Der Ein-/Standby-Netz- schalter befindet sich in der Standby-Position.
42 Sun StorageT ek 4 Gb FC NEM 20-Port Host Bus Adapter User’ s Guide • F ebr uar y 2008 Die folgende Warnung gilt nur für Geräte mit Standby- Netzschalter: Achtung – Beim Netzschalter dieses Geräts handelt es sich nur um einen Ein/Standby- Schalter .
Safety Agency Compliance Statement 43 Hinweis zur Laser-Konformität Sun-Produkte, die die Laser-Technologie verwenden, entsprechen den Laser-Anforderungen der Klasse 1.
44 Sun StorageT ek 4 Gb FC NEM 20-Port Host Bus Adapter User’ s Guide • F ebr uar y 2008 Nivel de ruido Emisiones acústicas declaradas de acuerdo con la norma ISO 9296 (decibelios A), en funciona.
Safety Agency Compliance Statement 45 Cubierta de la unidad del sistema Debe extraer la cubierta de la unidad del sistema informático Sun para instalar tarjetas, memoria o dispositivos de almacenamiento internos. Vuelva a colocar la cubierta antes de encender el sistema informático.
46 Sun StorageT ek 4 Gb FC NEM 20-Port Host Bus Adapter User’ s Guide • F ebr uar y 2008 Danmark Advarsel! – Litiumbatteri — Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med batteri af samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren.
47 Regulatory Compliance Statements Y our Sun product is marked to indicate its compliance class: • Federal Communications Commission (FCC) — USA • Industry Canada Equipment Standard for Digital.
48 Sun StorageT ek 4 Gb FC NEM 20-Port Host Bus Adapter User’ s Guide • F ebr uar y 2008 BSMI Class A Notice The following statement is applicable to products shipped to T aiwan and marked as Class A on the pr oduct compliance label.
Regulatory Compliance Statements 49 CCC Class A Notice The following statement is applicable to products shipped to China and marked with “Class A” on the pr oduct’s compliance label.
50 Sun StorageT ek 4 Gb FC NEM 20-Port Host Bus Adapter User’ s Guide • F ebr uar y 2008.
51 Index A Attention button, 17, 1 8 B BIOS POST, 30 C cable length, maximum, 2 channel LEDs, 13 chassis monitoring module (CMM) firmware, 5 using ILOM, 14 compliance statements regulatory, 47 safety.
52 Sun StorageT ek 4 Gb FC NEM 20-Port Host Bus Adapter User’ s Guide • Februar y 2008 links connected to blades status, 18 Linux driver , known issues, 3 0 supported versions, 4 Locator LED and b.
デバイスSun Microsystems SG-XPCIE20FC-NEM-Zの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sun Microsystems SG-XPCIE20FC-NEM-Zをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSun Microsystems SG-XPCIE20FC-NEM-Zの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sun Microsystems SG-XPCIE20FC-NEM-Zの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sun Microsystems SG-XPCIE20FC-NEM-Zで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sun Microsystems SG-XPCIE20FC-NEM-Zを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSun Microsystems SG-XPCIE20FC-NEM-Zの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sun Microsystems SG-XPCIE20FC-NEM-Zに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSun Microsystems SG-XPCIE20FC-NEM-Zデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。