Sunpentown IntlメーカーWA-1410Hの使用説明書/サービス説明書
ページ先へ移動 of 20
Model No. WA-1400E Model No. WA-1410E Model No. WA-1400H Model No. WA-1410H ʳ It is important that you read these instructions before using your new purchase and we strongly recommend that you keep them in a safe place for futur e refer ence. Instruction Manual P O R T A B L E Air Conditioner 05-03-457 A029-OK.
TABLE OF CONTENTS THANK YOU ENERGY SAVING TIPS………..……………………………………………….. 2 SPECIFICATIONS..……………………………………………………………….3 BEFORE USE……….…………………………………………………………….
2 THANK YOU Thank you for choosing the portable air conditioner from SPT USA , a leading brand in indoor air treatment. We would like you to enjoy the many benefits this unit offers, so please take the time to read this manual carefully and take full advantage of the many advanced features that your SPT USA Air Conditioner offers you.
SPECIFICATION Model no. WA-1400E WA-1410E WA-1400H WA-1410H Cooling capacity 14000 BTU/hr 14000 BTU/hr Heating capacity - 14000 BTU/hr Power/Ampere consumption for cooling* 1250W/ 11.0A 1250W/ 11.0A Power/Ampere consumption for heating* - 1250W/ 11.0A Air volume (max.
4 BEFORE USE Important! Transport the unit in an upright position only or leave in upright position for at least 2 hours before use. Keep at least 20 inches away from the wall.
PARTS Front Back FIG. 5 FIG.6 1. Control Panel 2. Air outlet 3. Carrying handle 4. Caster 5. Air filter 6. Air inlet 7. Exhaust air outlet 8. Water stopper / drainage point 9. Cord storage Accessories 10. Inward adaptor - for insertion over hose and connect to back of the air conditioner.
INSTALLATION EXHAUST PIPE INSTALLATION The unit is a portable air conditioner that may be moved from room to room. 1. Using the foam strips / Window installation Used to cover the window gap and can be cut to size if necessary. FIG.8 • Attach hose to unit and insert other end through the foam strip.
Mounting of the exhaust pipe • Use only the hose provided. Attach hose to back of unit by connecting the adaptor. • Avoid kinks and sharp bends in the exhaust hose as this will cause expelled moist air to build up and the unit will overheat and shut down.
Installing the Carbon Filter 1. Remove the filter frame from the unit. 2. Unclip and remove one side of the frame. 3. Remove the active carbon filter from its plastic bag. 4. Insert the active carbon filter into the filter frame. 5. Replace the other half of the frame.
Control panel FIG.17 1. Automatic mode indicator 2. Cooling mode indicator 3. Fan mode indicator 4. Heating mode indicator (for cool & heat models only). 5. Low ventilation indicator 6. Medium ventilation indicator 7. High ventilation indicator 8.
Auto Mode When this mode is selected, the unit is preset to the following temperature settings and unit will only start to: Cool when room temperature is higher than 75°F Heat when room temperature is lower than 68°F (W A-1400H &W A-1410H models only) If room temperature is between 68°F and 75°F , unit will stay in Fan mode.
Setting ventilation speed 1. Press SPEED button to choose the desired ventilation speed: High, Medium or Low. The indicator respective speed will light on at the same time.
Regulating air flow direction FIG. 19 Adjust louver on the air vent horizontally to control air flow direction. NOTICE ! The compressor will start approximately 3 minutes after the compressor is turned off (this will help prolong the life of the compressor).
. DRAINAGE During the process of cooling or heating, some water will be extracted from the air. Most of this water is used to cool the cooling coils and make the unit run more efficiently. This is a feature not found in most other portable air conditioners.
NOTE The drain tube must be at or below the outlet level. Water Full (full water) indicator will not function in this mode of drainage. If you wish to extend the water tube, please connect with another tube (outside diameter 3/4"). FIG.
. MAINTENANCE Always unplug the unit before cleaning and maintenance. Cleaning the Housing Use a soft, damp cloth to wipe the body clean. Never use strong chemicals, oil-based products, detergents, chemically treated cloths or other cleaning solutions.
. TROUBLE SHOOTING The unit doesn’t run or only runs in fan mode Is the machine plugged in? Is the main power supply on? Is room temperature within working temp range? Is unit set in Auto mode? Select Cool or Heat mode and set to proper temperature.
. DEFECTIVE NOTICE If this pr oduct is defectiv e or not working pr operly Please DO NO T re turn to y our retail stor e Please contact us dir ectly with an y Service or T echnical Assistance Contact .
Portable Air Conditioner / Heater Your Guarantee If this product is found to be faulty as a result of faulty materials or workmanship within one year from date of purchase, it will be repaired or replaced free of charge. This guarantee is subject to the following terms: SPT USA , must be notified of the fault.
SAFETY POWER SUPPL Y CORD: This Portable Air Conditioner is provided with a Leakage Current Detection and Interruption circuit (LCDI) built into the plug of the power supply cord. This device provides protection to reduce the risk of fire due to arcing faults in the power-supply cord.
デバイスSunpentown Intl WA-1410Hの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sunpentown Intl WA-1410Hをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSunpentown Intl WA-1410Hの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sunpentown Intl WA-1410Hの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sunpentown Intl WA-1410Hで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sunpentown Intl WA-1410Hを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSunpentown Intl WA-1410Hの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sunpentown Intl WA-1410Hに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSunpentown Intl WA-1410Hデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。