SC745TQ-R800(B) SC745S2-R800(B) SC745TQ-800(B) SC745S2-800V(B) USER’S MANUAL 1.0 S UPER SC745 CHASSIS Series.
SC745 Chassis Manual ii The information in this User ’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be conta.
iii Preface Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SC745 4U chassis. Installa- tion and maintenance should be performed by experienced technicians only .
SC745 Chassis Manual iv Notes.
v Preface Manual Organization Chapter 1: Introduction The fi rst chapter provides a checklist of the main components included with this chassis and describes the main features of the SC745 chassis. This chapter also includes contact information. Chapter 2: System Safety This chapter lists warnings, precautions, and system safety .
SC745 Chassis Manual vi Compatible Backplanes This section lists compatible cables, power supply specifi cations, and compatible backplanes. Not all compatible backplanes are listed. Refer to our Web site for the latest compatible backplane information.
vii Preface T able of Contents Preface About This Manual ............................................................................... iii Manual Organization ............................................................................ v Chapter 1: Introduction 1-1 Overview .
SC745 Chassis Manual viii Chapter 4: System Interface 4-1 Overview ........................................................................................... 4-1 4-2 Control Panel Buttons ..............................................................
ix Preface T o install the air shroud ............................................................... 5-21 T o check the server's air fl ow ..................................................... 5-22 Installation Complete ........................
SC745 Chassis Manual x Appendices Appendix A: SC745 Chassis Cables A-1 Overview .......................................................................................... A-1 A-2 Cables Included with SC745TQ Chassis (SAS/SA T A) ................ A-1 A-3 Cables Included with SC745S Chassis (SCSI) .
Chapter 1: Introduction 1-1 Overview Supermicro’s SC745 4U chassis features a unique and highly-optimized design. The chassis is equipped with high effi ciency power supply . High performance fans provide ample optimized cooling for FB-DIMM memory modules and 8 hot-swap drive bays offer maximum storage capacity in a 4U form factor .
SC745 Chassis Manual 1-2 1-3 Chassis Features The SC745 4U high performance chassis includes the following features: CPU The SC745 Chassis supports a DP Dual-core Xeon processor . Please refer to the motherboard specifi cations pages on our web site for updates on supported processors.
1-3 Chapter 1: Introduction 1-4 Contacting SuperMicro Headquarters Address: SuperMicro Computer , Inc. 980 Rock A ve. San Jose, CA 95131 U.S.A. T el: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.
SC745 Chassis Manual 1-4 Notes.
2-1 Chapter 2: System Safety Chapter 2: System Safety 2-1 Overview This chapter provides a quick setup checklist to get your chassis up and running. Following the steps in order given should enable you to have your chassis setup and operational within a minimal amount of time.
SC745 Chassis Manual 2-2 2-4 Electrical Safety Precautions Basic electrical safety precautions should be followed to protect yourself from harm and the SC745 from damage: Be aware of the locations of the power on/off switch on the chassis as well as the room’s emergency power-of f switch, disconnection switch or electri- cal outlet.
2-3 Chapter 2: System Safety DVD-ROM Laser: CAUTION - this server may have come equipped with a DVD-ROM drive. T o prevent direct exposure to the laser beam and hazard- ous radiation exposure, do not open the enclosure or use the unit in any unconventional way .
SC745 Chassis Manual 2-4 T ouch a grounded metal object before removing any board from its anti- static bag. Do not let components or PCBs come into contact with your clothing, which may retain a charge even if you are wearing a wrist strap.
3-1 Chapter 3: Chassis Components Chapter 3: Chassis Components 3-1 Overview This chapter describes the most common components included with your chassis. Some components listed may not be included or compatible with your particular chassis model. For more information, see the installation instructions detailed later in this manual.
Chassis Manual 3-2 Power Supply Each SC745 chassis model includes a high-effi ciency power supply rated at 800 W atts. In the unlikely event your power supply fails, replacement is simple and can be done without tools. Air Shroud Air shrouds are shields, usually plastic, that funnel air directly to where it is needed.
4-1 Chapter 4: System Interface Chapter 4: System Interface 4-1 Overview There are several LEDs on the control panel as well as others on the drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specifi c components.
Chassis Manual 4-2 4-2 Control Panel Buttons The re ar e t wo push - bu t tons l oc ated on t he f ront of t he c hass is. Th ese a re powe r on /of f button and a rese t but ton. Powe r: T he mai n powe r switc h is us ed to ap ply o r rem ove power f rom the p ower s uppl y to the s er ver syste m.
4-3 Chapter 4: System Interface NIC 2 : I ndic ates net wor k ac tiv it y on G L A N2 w hen fl ash ing. NIC 1 : Indic ates n et wor k ac tiv it y on G L A N1 when fl ashin g. HDD: Indic ates I D E cha nnel a ct ivi t y . SAS / SA T A dri ve, SC SI dr ive, an d / or DVD - RO M dr ive ac tiv it y whe n fl ashing.
Chassis Manual 4-4 c onne ct ion to t he S A T A bac kpl ane en able s thi s LED to bl ink on an d of f w hen th at par ti cul ar dr ive is b eing a cc e sse d. Red: The red LED to indicate an SAS/SA T A drive failure. If one of the SAS/ SA T A drives fail, you should be notifi ed by your system management software.
5-1 Chapter 5: Chassis Setup and Maintenance Chapter 5: Chassis Setup and Maintenance 5-1 Overview This chapter covers the steps required to install components and perform maintenance on the chassis. The only tool you will need to install components and perform maintenance is a Phillips screwdriver .
Chassis Manual 5-2 5-3 Installation Step 1: Remove the Chassis Cover T o remove the chassis cover: 1. Push the cover latch button to release the latch handle. 2. Pull the cover off the chassis using the latch handle. Figure 5-1: Removing the Chassis Cover Front Cover T o replace the chassis cover: 1.
5-3 Chapter 5: Chassis Setup and Maintenance The Front Cover The front cover houses up to eight hot-swappable hard drives. The cover can be locked to prevent unauthorized access. The key to this lock is shipped with the system. T o remove the front cover 1.
Chassis Manual 5-4 5-4 Installation Step 2: Confi gure the Storage Module Storage Module T ower or Rack Confi guration The SC745 chassis is shipped in tower mode and can be immediately used as desktop server . If the chassis is to be used in a rack, you must turn the storage module 90 degrees.
5-5 Chapter 5: Chassis Setup and Maintenance T o rotate the storage module for rack mounting: 1. Open the chassis cover . 2. Locate the storage module and disconnect any cables from the storage module to any component in the chassis. 3. Push the storage module release lever .
Chassis Manual 5-6 Adding Drives to the Storage Module The storage module includes three full sized drive bays and the front LED panel. The storage module can be set up one of three ways: A. Add up to three extra hard drives to the drive trays. B. Add up to three peripheral drives (CD-ROM, DVD-ROM, etc.
5-7 Chapter 5: Chassis Setup and Maintenance Drive T ray Release T abs T o add up to three hard drives to the drive trays: 1. Open the chassis cover . 2. Locate the drive tray release tab for the slot you want to place the peripheral drive. 3. Push the drive tray toward the front of the chassis.
Chassis Manual 5-8 4. Place the hard drive to the hard drive tray . Make sure The hard drive can be SAS or SCSI depending on your motherboard. The hard drive may not completely fi ll the tray . 5. Secure the hard drive to the tray with four screws from the bottom.
5-9 Chapter 5: Chassis Setup and Maintenance Drive T ray Release T abs T o add up to three peripheral drives (DVD-ROM, CD-ROM, fl oppy drive, etc.) to the drive trays: 1. Open the chassis cover . 2. Locate the drive tray release tab for the slot you want to place the peripheral drive.
Chassis Manual 5-10 4. Remove the hard drive tray rails from the hard drive tray . T o do this, you must remove two screws from each side. 5. Attach the rails to a DVD-ROM, CD-ROM, fl oppy drive, or other peripheral. The rails should fi t any standard sized peripherals.
5-1 1 Chapter 5: Chassis Setup and Maintenance Drive T ray Release T abs T o add fi ve hard drives using a SuperMicro mobile rack: The SC745 chassis accepts a CSE-M35S (SCSI) or CSE-M35T -1/CSE-M35TQ mobile rack to install extra hot swappable hard drives.
Chassis Manual 5-12 Mobile Rack Hard Drive Rails 4. Remove the hard drive tray rails from the hard drive tray . T o do this, you must remove two screws from each side. Do this for all three hard drive trays. 5. Attach the rails to a DVD-ROM, CD-ROM, fl oppy drive, or other peripheral.
5-13 Chapter 5: Chassis Setup and Maintenance T o install hard drives to the chassis: The drives are mounted in drive carriers to simplify their installation and removal from the chassis. These carriers also help promote proper airfl ow for the drive bays.
Chassis Manual 5-14 Figure 5-1 15: Remove Dummy Drive T ray 6. Secure the hard drive to the tray using four screws. 7 Insert the hard drive into the chassis. T o do this: 7a. Press the hard drive release button to extend the drive tray handle. 7b. Insert the hard drive into the chassis and close the handle to lock the hard drive into place.
5-15 Chapter 5: Chassis Setup and Maintenance I/O Shield 5-6 Installation Step 4: Install the Motherboard I/O Slot Shield The I/O shield holds the motherboard ports in place. Install the I/O shield before you install the motherboard. Figure 5-17: SC745 Chassis I/O Shield T o install the I/O shield: 1.
Chassis Manual 5-16 Permanent and Optional Standoffs Standoffs prevent short circuits by securing space between the motherboard and the chassis surface. The SC745 chassis packaging includes optional standof fs (hexagon shaped posts). These standof fs accept the rounded Phillips head screws included in the SC745 accessories packaging.
5-17 Chapter 5: Chassis Setup and Maintenance T o install the motherboard: 1. Review the documentation that came with your motherboard. Become familiar with component placement, requirements, and precautions. 2. Disconnect the power supply and lay the chassis on a fl at surface.
Chassis Manual 5-18 Power Supply Connections Connect each of the following cables, as required, by your motherboard manu- facturer . In some instances, some cables may not need to be connected.
5-19 Chapter 5: Chassis Setup and Maintenance Add-on Card/Expansion Slot Setup After motherboard installation, install add-on cards to the chassis, such as PCI cards. T o install add-on and expansion cards: 1. Locate the release tab on the top of the PCI bracket.
Chassis Manual 5-20 4. Remove the screw holding the bracket in place and pull the bracket from the chassis. 5. Install your PCI card or other add-on card into the PCI slot bracket and moth- erboard. T o do this, slide the PCI card (with "L" bracket) into the PCI slot and secure the card to the motherboard.
5-21 Chapter 5: Chassis Setup and Maintenance 5-7 Installation Step 5: Install the Air Shroud Figure 5-21: Air Shroud Air shrouds concentrate airfl ow to maximize fan effi ciency .
Chassis Manual 5-22 Figure 5-22: Air Shroud in place T o check the server's air fl ow 1. Make sure there are no objects to obstruct airfl ow in and out of the server . In addition, if you are using a front bezel, make sure the bezel's fi lter is replaced periodically .
5-23 Chapter 5: Chassis Setup and Maintenance Five heavy duty fans provide cooling for the chassis. Three fans are located in the front of the chassis with two fans in the rear . These fans circulate air through the chassis as a means of lowering the chassis internal temperature.
Chassis Manual 5-24 Rear Fan Release T ab Figure 5-24: Rear Chassis Fans T o replace a rear chassis fan: 1. Press the rear fan release tab. 2. Pull the fan from the chassis top fi rst. 3. Place the new fan in the chassis bottom fi rst. 4. Push the fan fully into the housing until the fan clicks into place.
5-25 Chapter 5: Chassis Setup and Maintenance Depending on your chassis model, the SC745 Chassis has a 700W or 800W (re- dundant) power supply . This power supply is auto-switching capable. This enables it to automatically sense and operate at a 100v to 240v input voltage.
Chassis Manual 5-26 Notes.
6-1 Chapter 6: Rack Installation Chapter 6: Rack Installation 6-1 Overview This chapter provides a quick setup checklist to get your chassis up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time.
Chassis Manual 6-2 Rack Precautions - Ensure that the leveling jacks on the bottom of the rack are fully extended to the fl oor with the full weight of the rack resting on them. - In single rack installation, stabilizers should be attached to the rack.
6-3 Chapter 6: Rack Installation Reduced Airfl ow Equipment should be mounted into a rack so that the amount of airfl ow required for safe operation is not compromised. Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.
Chassis Manual 6-4 6-4 Rack Mounting Instructions This section provides information on installing the SC745 chassis into a rack unit with the rails provided. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly .
6-5 Chapter 6: Rack Installation T o remove the chassis top cover 1. Locate the chassis cover lock (blue lever) at the rear of the chassis cover . 2. Slide the chassis cover lock to the right and push chassis cover forward. 3. Lift the chassis top cover off the chassis.
Chassis Manual 6-6 Figure 6-2. Identifying the Inner Rails and Chassis Handles Chassis Handle Inner Rails Chassis Handle Screw Chassis Rail Screw Identifying the Sections of the Rack Rails The chassis package includes two rack rail assemblies in the rack mounting kit.
6-7 Chapter 6: Rack Installation Figure 6-3. Installing the Inner Rack Rails T o install the chassis handles and inner rails 1. Locate the chassis handles (2) and handle screws (6). 2. Align the chassis handle with the front of the chassis and secure with the three chassis handle screws.
Chassis Manual 6-8 T o install the outer rails to the rack 1. Attach the front and rear short brackets to the outside of the long bracket. Both bracket ends must face the same direction. 2. Adjust both the brackets to the proper distance so that the rail fi ts snugly into the rack.
6-9 Chapter 6: Rack Installation Figure 6-5. Installing the Rack Rails T o install the chassis into a rack 1. Confi rm that chassis includes the inner rails and the outer rails.
Chassis Manual 6-10 6-5 T ower Mounting Instructions The SC745 chassis is shipped with the chassis cover and feet pre-installed. T o use the chassis as a desktop server , no other installation is required. Use the instructions in this section if you have converted the chassis for rack use and need to return the chassis to tower mounting.
6-1 1 Chapter 6: Rack Installation T o place chassis feet 1. Place the chassis foot in the foot receptacle and slide the foot toward the front of the chassis. The foot should lock into place. 2. Secure the foot to the chassis using one screw enclosed in the packaging.
Chassis Manual 6-12 Notes.
1 Appendicies Appendicies Appendix A: Compatible Cables Appendix B: SC745 Power Supply Specifi cations Appendix C: SCA 743S2 Backplane Manual Appendix D: SAS 743TQ Backplane Manual Appendix E: CSE-M3.
Appendicies 2 Notes.
A-1 Appendix A: Chassis Cables Appendix A: SC745 Chassis Cables A-1 Overview This appendix lists supported cables for your chassis system. It only includes the most commonly used components and confi gurations. For more compatible cables, refer to the manufacturer of the motherboard you are using and our Web site at: www .
Chassis Manual A-2 A-4 Compatible Cables These cables are compatible with the SC745 Chassis. Description: This cable has one SFF-8484 (32 pin) connector on one end and 4 SAS connectors (7 pins each) at the other . This cable connects from the Host (motherboard or other controller) to the backplane SAS hard drive port.
A-3 Appendix A: Chassis Cables Extending Power Cables Although Super Micro chassis are designed with to be effi cient and cost-effective, some compatible motherboards have power connectors located in different areas. T o use these motherboards you may have to extend the power cables to the mother boards.
Chassis Manual A-4 Notes.
B-1 Appendix B: Power Supply Specifi cations Appendix B: SC745 Power Supply Specifi cations This appendix lists power supply specifi cations for your chassis system.
Chassis Manual B-2 Notes.
Rev . 1.0 SCA 743S2 Backplane USER'S GUIDE JP13 JP10.
ii SCA 743S Backplane User's Guide The information in this User ’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies t.
iii Safety Information and T echnical Specifi cations T able of Contents Chapter 1: Safety Guidelines 1-1 ESD Safety Guidelines ..................................................................... 1-1 1-2 General Safety Guidelines ..................
iv SCA 743S Backplane User's Guide Notes.
1-1 Safety Information and T echnical Specifi cations Chapter 1: Safety Guidelines T o avoid personal injury and property damage, carefully follow all the safety steps listed below when accessing your system or handling the components. 1-1 ESD Safety Guidelines Electric Static Discharge (ESD) can damage electronic com ponents.
1-2 SCA 743S Backplane User's Guide Notes.
2-1 Safety Information and T echnical Specifi cations JP13 JP10 Front Connectors Chapter 2: Jumper Settings and Pin Defi nitions 2-1 Front Connectors and Jumpers 1. GEM 318 Chips 2. Backplane Main (4-Pin) PWR: JP10 and JP15 3. SCSI Channel A: L VD1 4.
2-2 SCA 743S Backplane User's Guide 2-2 Front Connector and Pin Defi nitions Backplane Main Power 4-Pin Connector (JP10 and JP15) Pin# Defi nition 1 +12V 2 and 3 Ground 4 +5V #2. Backplane Main Power Connectors The 4-pin connector , designated JP10 and JP15, provide power to the backplane.
2-3 Safety Information and T echnical Specifi cations Ultra320 SCSI Drive Connector Pin Defi nitions (L VD1 and L VD2) Pin# Defi nition Pin # Defi nition 1 +DB (12) 35 -DB (12) 2 +DB (13) 36 -DB (.
2-4 SCA 743S Backplane User's Guide 2-3 Front Jumper Locations and Pin Defi nitions Explanation of Jumpers T o modify the operation of the backplane, jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function of the connector .
2-5 Safety Information and T echnical Specifi cations Backplane LED LED ST A TE SPECIFICA TION D4 ON Overheat/Drive Failure LED Indicator (Red light: fl ashing, Buzzer: On) FRONT LED INDICA TORS.
2-6 SCA 743S Backplane User's Guide 2-4 Rear Connectors and LED Indicators Rear SCA Connectors Rear Connector Connector Number SCA Drive Number SCA1 A - ID #0 SCA HDD #0 SCA8 A - ID #1 SCA HDD #1.
2-7 Safety Information and T echnical Specifi cations 2-5 SCSI (Super) GEM Installation Instructions for the Windows Operating System The following instructions describe how to install the SCSI GEM Driver for the Windows OS systems. This driver is not necessary for other Operating Systems.
2-8 SCA 743S Backplane User's Guide Notes.
Rev . 1.0 SAS 743TQ Backplane USER'S GUIDE + +12V +12V GND GND GND GND +5V +5V 48 1 16 64 49 H12 H7 H4 M68 M70 M71 M72 M73 M75 M76 M80 M81 M82 M83 M84 M85 M86 M87 H5 H6 H3 M88 M89 M90 M91 M92 M93 M94 M95 M96 M97 MM2 MM3 SAS743TQ REV 3.
1-2 S AS 743TQ Backplane User ’s Guid e T a ble of C onten ts Safety Informat ion and T echnical Specificati ons ............. ............. ........ 1-3 1. Safe ty Guidelin es ................. ............... .............. ............... ......
1-3 Safety Informat ion and T echni cal Spe cifications Safe ty In forma tion and T ech nical Spec ificat ions T o avoid personal injury and property damage, please carefully follow all the safety s.
1-4 S AS 743TQ Backplane User ’s Guid e +12V +12V GND GND GND GND +5V +5V 1 16 64 49 SAS743TQ REV 3.00 R S UPER H4 R259 2. Jumper Settings and Pin Definitions A. Front Connectors and Jumpers A-1 Front Jumper/Connector Locations A-2. Front Connectors #1.
1-5 Safety Informat ion and T echni cal Spe cifications Y ou must use the 4-pin power connectors: JP13, JP10 to provide ad equate power to the Backplane. See the table on the right for pin definitions. Pins # 1 2 & 3 4 Defini tion +12 V Ground +5V Backplane Main PWR 4-pin Con nector (J10) A-3.
1-6 S AS 743TQ Backplane User ’s Guid e +12V +12V GND GND GND GND +5V +5V 1 16 64 49 SAS743TQ REV 3.00 R S UPER H4 R259 A-5 Front Jumpers and Pin Definitions Front Ju mper/LE D Lo cations Front Jum.
1-7 Safety Informat ion and T echni cal Spe cifications SAS #0 * Front/R ear SAS Conn ector Loca tion T able +12V +12V GND GND GND GND +5V +5V 1 16 64 49 SAS743TQ REV 3.
1-8 S AS 743TQ Backplane User ’s Guid e ACT2 M9 H4 MM3 Rear View D26 B. Rear Connectors and LED Indicators B-1 Rear SAS Connector/LED Indicator Locations D8 D14 D7 D13 D6 D5 D12 D1 9 D1 8 D 20 D 21 .
1-9 Safety Informat ion and T echni cal Spe cifications Rear SAS Connectors B-2 Rear Connector/LED Indicator Descriptions Rear LED Indicators Rear SAS Connectors Connector Specification J1 SAS#0 HDD .
1-10 S AS 743TQ Backplane User ’s Guid e B-3 The AMI MG9072 SES-2 Controller (SCSI Enclosure Services-2) LED Indicators The AMI MG 9072 allows the system to use a set of pre-defined SES commands to monitor the status of disk drives and provide disk drive information to the user through LED indicators and alarms/buzzers.
1.0 ® S UPER USER'S GUIDE Mobile Rack CSE-M35S/CSE-M35T1.
S UPER CSE-M35S/CSE-M35T1 User's Guide 2 Table of Contents 1. Packaging List ...................................................................................................... 3 2 . Technical Specifications ...................................
3 CSE-M35S/CSE-M35T1 Supermicro’s CSE-M35S/CSE-M35T1 Mobile Rack Series offers the cutting edge technology with greater flexibility. The CSE-M35T1 supports five Se- rial ATA hot-swappable hard drives that yield a unparalleled storage capac- ity without compromising productivity by eliminating possible system down- time.
S UPER CSE-M35S/CSE-M35T1 User's Guide 4 2. Technical Specifications Occupancy Three (3) 5.25" Drive Bays Capacity Five (5) 1" SCA Ultra320/160 Hard Drives with SAF-TE built-in (*CSE-M3.
5 3. Jumper Settings A. Jumper Settings for the CSE-M35S (SCSI): Location of Jumpers Jumper Description Setting JP18 Buzzer Reset Closed: Enable, Open: Disable (*Default) JP21 SCSI Termination Closed:.
S UPER CSE-M35S/CSE-M35T1 User's Guide 6 B. Jumper Settings for the CSE-M35T1 (SATA): Location of Jumpers JP28 JP25 JP18 C hannel #1 Channel #2 ACT5 FAN Channel #3 Channel #4 Channel #5 ACT6 ACT7 ACT8 ACT1 ACT2 ACT3 ACT4 COM Pin 1 Pin 1 Key JP26 Ac tiv ity LED s- Pin De fini tio ns Act.
7 A. Accessing Hot Swappable Drives: 1.Push the release button located beside the drive LEDs (as shown below:) 4. Installation Procedures Installation Procedures (*Note: For the CSE-M35S: 1. SCSI IDs are assigned automatically by the backplane. Do not set IDs manually on the drives.
S UPER CSE-M35S/CSE-M35T1 User's Guide 8 3. Mount a drive in a carrier (as shown below:) 2. Swing the handle outward and pull out the unit (as shown below:).
9 B. Accessing the Exhaust Fan: 1.Push the tabs located on both sides of the unit (as shown be- low:) 2. Pull out the fan (as shown below:) (*Note: For the SC-942 Chassis, the CSE-M35 Rear Exhaust Fan should not be used.
S UPER CSE-M35S/CSE-M35T1 User's Guide 10 C. Accessing the Drive Backplane: 1. Unscrew the screw located on the side of the unit (as shown below:) 2.
デバイスSupermicro CSE-745TQ-920Bの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Supermicro CSE-745TQ-920Bをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSupermicro CSE-745TQ-920Bの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Supermicro CSE-745TQ-920Bの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Supermicro CSE-745TQ-920Bで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Supermicro CSE-745TQ-920Bを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSupermicro CSE-745TQ-920Bの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Supermicro CSE-745TQ-920Bに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSupermicro CSE-745TQ-920Bデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。