Data Sheet: Veta iHA 4804 0A033V* , 3.3V/4 0A Output Half Brick Series ©20 07 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 1 / 17 Datasheet DC - DC Power Modules Veta iH A48040A033V* Half Brick Series 48V Input, 3.3V/40A. Output Information furnished by TDK Innoveta is believe d to be accurate and reliable.
Data Sheet: Veta iHA 4804 0A033V* , 3.3V/4 0A Output Half Brick Series ©20 07 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 2 / 17 Platform Overview: Veta iHA 48 Series DC - DC Power Modules 48V Input, 1.
Data Sheet: Veta iHA 4804 0A033V* , 3.3V/4 0A Output Half Brick Series ©20 07 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 3 / 17 Ordering information: Product Identifier Packag.
Data Sheet: Veta iHA 4804 0A033V* , 3.3V/4 0A Output Half Brick Series ©20 07 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 4 / 17 Mechanical Specification : Unless otherwise specified tolerances are: x.x ± 0.5 mm [x.xx ± 0.02 in.
Data Sheet: Veta iHA 4804 0A033V* , 3.3V/4 0A Output Half Brick Series ©20 07 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 5 / 17 Absolute Maximum Ratings : Stress in excess of Absolute Maximum Ratings may cause perman ent damage to the device.
Data Sheet: Veta iHA 4804 0A033V* , 3.3V/4 0A Output Half Brick Series ©20 07 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 6 / 17 Electrical Data (continued) : Operating at Tc = 25 °C unless otherwise spec ified Output Characteristic Min Ty p Max Unit Notes & Conditions Output Voltage Initial Setpoint 3.
Data Sheet: Veta iHA 4804 0A033V* , 3.3V/4 0A Output Half Brick Series ©20 07 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 7 / 17 Electric al Characteristics: iHA48040A033V-001 Efficiency 70 75 80 85 90 95 0 4 8 12 16 20 24 28 32 36 40 Output Current (A) Efficiency, η (%) Vin = 36V Vin = 48V Vin = 75V Ta = 25 Deg C.
Data Sheet: Veta iHA 4804 0A033V* , 3.3V/4 0A Output Half Brick Series ©20 07 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 8 / 17 Electrical Characteristics (continued): iHA48040A033V-001 Current Limit 0 1 2 3 4 5 10 15 20 25 30 35 40 45 50 Output Current (A) Ou t pu t Voltage (V) Vin = 36V Vin = 48V Vin = 75V Ta = 25 Deg C.
Data Sheet: Veta iHA 4804 0A033V* , 3.3V/4 0A Output Half Brick Series ©20 07 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 9 / 17 Electrical Characteristics (continued): 0 1 10 .
Data Sheet: Veta iHA 4804 0A033V* , 3.3V/4 0A Output Half Brick Series ©20 07 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 10 / 17 Thermal Performance : 10 20 30 40 25 35 45 55 65 75 85 95 105 115 Ambient Temperature ( o C) Output Current (A) NC 0.
Data Sheet: Veta iHA 4804 0A033V* , 3.3V/4 0A Output Half Brick Series ©20 07 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 11 / 17 Thermal Performance (continued) : 0 5 10 15 20.
Data Sheet: Veta iHA 4804 0A033V* , 3.3V/4 0A Output Half Brick Series ©20 07 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 12 / 17 Thermal Management: An important part of the o.
Data Sheet: Veta iHA 4804 0A033V* , 3.3V/4 0A Output Half Brick Series ©20 07 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 13 / 17 Heat transfer by convection can be enhanced by increasing the airflow rate that the power module experiences.
Data Sheet: Veta iHA 4804 0A033V* , 3.3V/4 0A Output Half Brick Series ©20 07 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 14 / 17 Operating Information: Over - Current Protection: The power modules have current limit protection to protect the module during output overload and short circuit conditions.
Data Sheet: Veta iHA 4804 0A033V* , 3.3V/4 0A Output Half Brick Series ©20 07 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 15 / 17 percentage of Vout (%Vo) from Vo,nom, the trim.
Data Sheet: Veta iHA 4804 0A033V* , 3.3V/4 0A Output Half Brick Series ©20 07 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 16 / 17 Input/Output Ripple and Noise Measurements: 100KHz Voutput Cext 1 2 + 12uH 1 2 esr<0.7 Battery 100KHz + RLoad 1 2 esr<0.
Data Sheet: Veta iHA 4804 0A033V* , 3.3V/4 0A Output Half Brick Series ©20 07 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 17 / 17 than 2 M hours using the Telcordia TR - 332 calculation method. Improper handling or cleaning processes can adversely affect the appearanc e, testability, and reliability of the power modules.
デバイスTDK iHA48040A033V*の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
TDK iHA48040A033V*をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはTDK iHA48040A033V*の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。TDK iHA48040A033V*の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。TDK iHA48040A033V*で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
TDK iHA48040A033V*を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はTDK iHA48040A033V*の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、TDK iHA48040A033V*に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちTDK iHA48040A033V*デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。