1 User Instructions 9350-7713-000 Rev . B, 3/2005 Model EMS-4001 Exp ansion Master St ation Audiocom ® Intercom Systems.
2 FCC S t atement This equipment uses, and can radiate radio frequency energy that may cause interference to radio communications if not installed in accordance with this manual.
3 T able of Contents Description ................................................................................ 4 Featur es ..................................................................................... 4 Installation ........................
4 Description The EMS-4001 adds four powered intercom channels to an MS-2001 Master Station, and it provides talk, listen and call buttons for the added channels. Up to four EMS-4001 Expansion Master Stations may be connected to the MS- 2001 to add up to 16 channels (18 channels total).
5 9. Program Inputs Connector and T rimmers : Each intercom channel has its own program input and level adjust trimmer . For each program input, there is an internal jumper which routes the program either to the intercom channel only , or to both the intercom channel and the MS-2001 headset or speaker (default setting).
6 W ARNING The following instructions are for use by qualified personnel only . T o avoid electric shock, do not remove the cover unless you are qualified to do so. A VERTISSMENT Les instructions qui suivent s’adressent uniquement a un technicien qualifie.
7 T able 1 - EMS-4001 configuration switch settings..
8 Mounting Configurations The EMS-4001 mounts in a standard 19 inch equipment rack and is 1 rack unit high. Install the two supplied rack mount cosmetic covers when installing the EMS-4001 in the rack. When rack mounting components, you may not be able to access the sidetone trimmers after the components have been mounted.
9 Figure 3 - Example of EMS-4001 in a system. Power-Up Plug in the power cord. The EMS-4001 channels power -up identically to channels one and two of the MS-2001. Refer to the MS-2001 User Instructions for all power-up information. The MS-2001 and EMS-4001 can be powered up in any order .
10 Operation The EMS-4001 channels operate identically to channels one and two of the MS-2001. Refer to the MS-2001 User Instructions for all operating information. S pecifications General Input and Output Power: AC Input: 100-240 V AC, 50/60 Hz Channel Power (each channel): 24 ±1 VDC, 2 A Dimensions: 1.
11 Call Signaling: Send: 20 kHz ±100 Hz, 0.5 V rms ±10% Receive: 20 kHz ±800Hz, 100 mV rms Mic-Kill Frequency: Send: 24 kHz ±100 Hz, 0.5 V rms ±10% Receive: 24 kHz ±800 Hz, 100 mV rms Noise Cont.
デバイスTelex EMS-4001の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Telex EMS-4001をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはTelex EMS-4001の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Telex EMS-4001の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Telex EMS-4001で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Telex EMS-4001を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はTelex EMS-4001の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Telex EMS-4001に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちTelex EMS-4001デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。