Telularメーカー900, 1800, 1900の使用説明書/サービス説明書
ページ先へ移動 of 48
12/15/04 Part Number 56031701 P HONECELL ® SX6P GSM • Fixed W ir eless Phone 850/1800/1900 MH Z GSM (T RI B AND ) AND 900/1800/1900 MH Z GSM (T RI B AND ) MODELS U SER M ANU AL.
Phonecell ® SX6P GSM i User Manual Fixed Wireless Phone Serial Cable or USB Cable (SX6P-300G series only) This manual is for use with all SX6P-200G and SX6P-300G series deskphones only . T o determine which model of phone you have, pick up the phone and view the label underneath for verification.
Phonecell ® SX6P GSM ii User Manual SX6P MENU STRUCTURE Phonebook Service Numbers View Names Add Name Settings Messages Received Messages Saved Messages Create Message Message Settings V oicemail Inf.
Phonecell ® SX6P GSM iii User Manual Before installing your Phonecell ® SX6P , carefully remove the contents from the shipping carton and check for evidence of shipping damage. If damage is found, contact your Authorized T elular Distributor or shipping agent immediately .
Phonecell ® SX6P GSM iv User Manual T ABLE OF CONTENTS QUICK CONNECTION GUIDE .......................................................................................i SX6P MENU STRUCTURE................................................................
Phonecell ® SX6P GSM v User Manual SUPPLEMENT AR Y SER VICES (NETWORK DEPENDENT) .....................................20 In-Call Options .........................................................................................................20 Call Divert (Forwarding) .
Phonecell ® SX6P GSM 1 User Manual SX6P SETUP SIM Card Installation The SX6P requires a Subscriber Identification Module (SIM) for normal operation. The service provider supplies the SIM card, which carries the account information needed to operate the SX6P .
Phonecell ® SX6P GSM 2 User Manual Battery Operation The SX6P will recharge it s battery pack when connected to AC power . If AC power is interrupted, the SX6P will continue to operate, using power from the battery . (S tandby and talk-times will vary based upon phone usage during power interruption.
Phonecell ® SX6P GSM 3 User Manual W all-Mounting 1. Remove the mounting clip from the cradle and re-insert it with the tab pointing up - see Figures 7 and 8. 2. Mark two hole locations 83 mm (3-1/4 inches) vertically apart and drill two holes into the wall.
Phonecell ® SX6P GSM 4 User Manual Figure 11 – SX6P AC power connection. AC Power Cord Wall Socket Power Supply AC Power Input Barrel Connector Connect the SX6P to AC Power 1. Connect the barrel connector of the power supply to the AC power input on the rear panel of the SX6P - see Figure 1 1 .
GETTING TO KNOW YOUR SX6P Function Keys Operation of the SX6P is accomplished through the function keys on the keyp ad of the unit - see Figure 12 . Figure 12 – SX6P keypad and function keys. LCD Screen - Displays icons, information, and menu options necessary to operate the SX6P .
Phonecell ® SX6P GSM 6 User Manual LCD Screen Icons Icons displayed on the LCD screen indicate the features in use, the st atus of the phone, signal strength and battery status - see Figure 13 . Service Indication Full Service When powered on, the SX6P will display a wakeup banner (the 300G models LCD screen and keypad backlight will also light).
CALL FUNCTIONS Making Calls 1. Pick up the handset or press the SPEAKERPHONE key . The SX6P is now “of f-hook.” 2. Listen for dial tone. 3. Dial the phone number . The dialed number will be displayed. The name will also be displayed if it is stored in the phonebook.
SX6P BASIC FEA TURES Date and Time Settings The SX6P allows customization of the date, time, time zone, and time format (12 or 24 hour). Set the Date 1. Press the MENU key . 2. Select Clock . 3. Scroll to Set Date, then press the CHANGE key . 4. Enter the desired date.
Adjust Alert T ones (Ringer) Alert tones can be customized for different types of calls, such as voice or text. 1. Press the MENU key . 2. Select Settings , then select Audio Settings . 3. Use the arrow keys to scroll through the alert types. 4. Select the desired alert sound.
Keypad Buttons for T ext Entry (Multitap) There are three or four letters (as well as a number) assigned to each key on the telephone keypad. During text entry , pressing a key displays the first letter , then cycles through the other letters. For example, if the number 3 is pressed, a “D” will appear .
Speed Dialing S peed dialing permits one-touch dialing for up to 10 telephone numbers stored in the phone book. 0 through 9 on the keypad are used for speed dialing. Y ou must press and hold the corre- sponding key for 2 seconds to use speed dial. Assign a Number to a Speed Dial Location 1.
Phonecell ® SX6P GSM 12 User Manual SX6P ADDITIONAL FEA TURES Call Logs The SX6P stores the telephone numbers of the last ten outgoing calls and the last ten incoming calls with the dates and times of the calls. These numbers are displayed and can be dialed directly from the call log.
Set Alarm to Repeat Daily 1. Press the MENU key . 2. Select Clock , then select Set Alarm . 3. Select Repeat Daily . T urn Alarm On/Off 1. Press the MENU key . 2. Select Clock , then select Set Alarm . 3. Select Alarm S tatus . 4. Select On or Off . 5.
Call Settings Minute Minder When turned on, the Minute Minder emits a low audible tone once every minute while a call is active. 1. Press the MENU key . 2. Select Settings , then select Call Settings. 3. Select Minute Minder , then select On or Off as desired.
Network Settings Network settings allow selection of a desired network and addition of a network operator to the network list. Automatic Selection This option allows the SX6P to select the network automatically , based on the SIM Card account information.
Add New Network If a known network is not on the list, it can be added. The Country Code, Network Code, and Network Name must be provided in order to add a network to the list. Once added to the network list, the network can be accessed via the Set Preferred Network option.
Phonecell ® SX6P GSM 17 User Manual Change SIM PIN1 SIM PIN1 must be enabled and a valid PIN must be entered before this menu item will appear . 1. Press the MENU key . 2. Select Settings , then select Security Settings . 3. Select SIM PIN1 . 4. Select Change PIN .
Add Additional Prefixes 1. Press the OPTIONS key , then select Add . 2. Enter the new prefix, then press the OK key . Edit Current Prefixes 1. Press the OPTIONS key , then select Edit . 2. Use the arrow and CLEAR keys to edit the prefix. 3. Press the OK key when finished.
Change Deskphone Lock PIN 1. Press the MENU key . 2. Select Settings , then select Security Settings . 3. Select Deskphone Lock , then select Change PIN.
SUPPLEMENT AR Y SER VICES (NETWORK DEPENDENT) In-Call Options The following options are available during a call. While in a call, press the MENU key to access these options. Options display based on call status. For example, Retrieve will only display if a call is on hold or if Call W aiting indicates a second incoming call.
Call W aiting Call W aiting enables notification of incoming calls when the SX6P is of f-hook (whether during a call or during dialing). T o respond to Call W aiting, press the FLASH key or the hook switch. Contact your service provider to activate Call W aiting.
V oicemail The VM key will blink and the envelope icon will display when there are new voicemail mes- sages. Contact your service provider to activate voicemail and for voicemail settings. Set V oicemail Access Numbers T ypically , your service provider will set the voicemail access numbers for you.
Forward T ext Messages 1. View the desired message. 2. Press the OPTIONS key , then select Forward . 3. Enter the desired number or press the NAME key to select a phonebook entry . 4. Press the OK key . 5. T o send the message, select Send Now . T o save the message to send at a later time, select Send Later .
Phonecell ® SX6P GSM 24 User Manual Message Settings Message Center The message center number is used to retrieve your text messages. Contact your service provider for this number . 1. Press the SMS key , then select Message Settings . 2. Select Message Center , then enter the number that your service provider gave you.
Network Call Barring The SX6P support s network call barring of incoming or outgoing calls and allows barring of spe- cific types of services, such as voice or data. Contact your service provider to activate network call barring. The following call barring options are available : • Foreign Calls: Does not allow international calls.
DA T A FEA TURES (SX6P-300G series only) When connected to a personal computer (PC), the SX6P is cap able of sending and receiving digital fax and data, sending and receiving email communications, and accessing the Internet. Data speeds may vary depending upon your cellular network.
Baud Rate A T Commands The SX6P will accept A T commands to setup the port speed. If you want to change the SX6P port speed for a session or keep the change permanent, or if you just want to see the profile set- tings, use the following A T commands from a terminal application (like HyperT erminal).
SX6P TROUBLESHOOTING T elephone Service is Not Working (Cannot make or receive calls) · Make sure the SX6P is powered on properly . · Make sure any equipment that is externally connected to the SX6P is correctly connected. · T est any externally connected equipment on a known system to verify operation.
CONFORMANCE ST A TEMENTS The SX6P 850/1900 Mhz models are in conformance with all applicable FCC requirement s. FCC Part 15 Class B Compliance This Phonecell ® SX6P model has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules.
Safe Operation Requirement The Phonecell ® SX6P must be either wall mounted or desk mounted and should not be operated when any person is within 203 mm (8 inches) of the antenna. T emperature Environment Operating T emperature: From -10°C to +50°C ; Up to 95% relative humidity (non-condensing).
Potentially Explosive Atmospheres T urn your Phonecell ® SX6P OFF when in any area with a potentially explosive atmosphere. It is rare, but your Phonecell ® SX6P or its accessories could generate sp arks. S parks in such areas could cause an explosion or fire resulting in bodily injury or even death.
W ARRANTY I. WHA T THIS W ARRANTY COVERS AND FOR HOW LONG: TELULAR CORPORA TION ('T elular") warrants to a distributor Buyer , or to a customer only if the customer is a Buyer directly from .
IV . WHA T THIS W ARRANTY DOES NOT COVER: (a) Subsequent upgrades and enhancements to the Product. (b) Defects, non-compliance or damage resulting from use of the Product in other than its normal and customary manner or environment. (c) Defects, noncompliance or damage from misuse, lightening, accident or neg- lect.
APPENDIX A PC SERIAL PORT SETUP FOR CIRCUIT SWITCHED DIGIT AL F AX AND DA T A ( not for use with GPRS) (SX6P-300G series only) Requirements: · GSM account with your network service provider including a circuit switched data and fax facility . · PC, laptop, notebook with a RS232 serial port.
4. The Inst all New Modem window may appear asking for the type of modem to install. Select "Other" followed by clicking the NEXT button. If this window does not appear , go to S tep 5. 5. The Inst all New Modem window will appear . Then, click on the "Don't detect my modem option" followed by clicking the NEXT button.
6. The Inst all New Modem will update again to select the manufacturer and the modem model.Select “S tandard Modem T ypes” from the Manufacture’s list. Select “S tandard 19200 bps Modem” from the Models list then click next. 7. The Inst all New Modem will update to select the COM port.
8. The Modems Properties window should appear . Click on the Properties button. 9. The S tandard 19200 bps Modem Properties window will open in the General t ab. Set as shown with the COM port you have selected. 10. Then click on the Connection t ab. Set as shown below .
1 1. Click on the Advanced button. Set as shown. 12. Click on OK and Close to back out of each window . Y our modem is now set up. NOTE : When using the SX6P for PC fax operation, make sure the modem connection uses sof tware flow control.
Phonecell ® SX6P GSM 39 User anual.
Phonecell ® SX6P GSM 40 User Manual.
Phonecell ® SX6P GSM 41 T echnical Manual.
©2004 T elular Corporation, all rights reserved. Part Number 56031701 647 North Lakeview Parkway V ernon Hills, Illinois 60061, USA T el: 847-247-9400 • Fax: 847-247-0021 E-mail: support@telular .
デバイスTelular 900, 1800, 1900の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Telular 900, 1800, 1900をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはTelular 900, 1800, 1900の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Telular 900, 1800, 1900の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Telular 900, 1800, 1900で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Telular 900, 1800, 1900を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はTelular 900, 1800, 1900の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Telular 900, 1800, 1900に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちTelular 900, 1800, 1900デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。