Part No. 304433-A Rev 00 November 1998 Installing the Ba yStac k 400 -ST1 Cascade Module.
© 1998 by Bay Networks, Inc. All rights res e rved. T rad emarks Bay Networks i s a registered tr ademark and BayStack is a t rademark of Bay Networks, Inc.
1 Intr oduction This guide pro vides procedures for installing the BayStack 400-ST1 Cascade Modules into suppo rted Bay Networ ks BayStack 450 switches that ar e configured with B ayStack 450 software version V1.1.0 or later . Y ou can determine the software v ersion of your switches b y accessing the System Characteristics screen for each switch.
2 Find t he Bay Networks prod uct for which you need documentation. Then locate the specific cate gory and model o r versio n for your har dware or soft ware product . Using Adobe Acrobat R eader , you can open the man uals and release notes, sear ch for the sections you need, and print t hem on most st andard printer s.
3 Contents of Shipment Each BayStack 400-ST1 shipm ent includes the following items ( Figur e 1 ): • One BayStack 400 -ST1 Cascade Module • One .30 meter (1 2 inch) cascade cable; part numb er 303978- A. • This guide ( Installing the BaySta c k 400-ST1 C as c ade Module ).
4 If an y items are missing or damaged, contact the sales agent or the cu stomer service representati ve from wh om you purchased the BayStack 400-ST1 cascade module.
5 Cascade A Out Connector Provides an attachmen t point for connecting this unit t o another unit via the cascade cable. A re t u r n cable fro m another unit’ s Cascade A Out conn ector to this unit’ s Cascade A In connector c ompletes the stack connection (see the ex ample shown in Figu re 3 ).
6 Cascade A I n Connector Provides an attachment point for accepting a cascade cable connection from an adjacent unit in the stack. A re t u r n cable from this unit’ s Cascade A Out connecto r to the adjacent unit’ s Casca de A In connector completes the stack connection (see the e xample shown in Figure 3 ).
7 Base Unit Descr iption The base unit is a unique stack un it that can be selected by the Unit Select switch o n the front -panel of the 400-ST1 cascade module.
8 • Stack IP MA C address --- The s tac k IP MAC add r ess is automatically assigned during the stack in itialization: The base unit’ s MA C address, with a softwar e offset, is used for the stack IP MA C address.
9 • T emporary Base Unit --- If an assigned base unit fails, the next unit in the stack order automatically becom es the new temp or ary b ase unit . This change is ind icated by the Base LED on the temporary base unit’ s LED displa y panel turn ing on (ye llow).
10 Stack Configurations As sho w n in Figur e 4 , the cascade connectors and cables on the 400-ST1 front-panel provide the ability to stack up to eight BayStack switches. W ith 400-4TX MD As installed in each switch, the stack can accom modate a maximum of 224 switch p orts.
11 Figure 4. Stack Up Configuratio n Example Unit 7 Unit 8 1 = Last unit 2 = Base unit 3 = Cascade cable (PN 303978-A) 4 = Cascade max-return cable (PN 303979-A) BS0033A Unit 5 Unit 6 Unit 3 Unit 4 Un.
12 Figure 5. Stack Do wn Configuration Examp le Unit 2 1 = Base unit 2 = Last unit 3 = Cascade cable (PN 303978-A) 4 = Cascade max-return cable (PN 303979-A) BS0034A Unit 1 Unit 4 Unit 3 Unit 6 Unit 5.
13 Certain n etwork m anagement station (NMS) applicatio ns assume a stack do wn configura tion for the graphical user interface (GUI) that represents the stack (see Figur e 5 on page 12 ). F or this reason, Bay Netwo rks recom mends that you alw ays configu re the top unit in the stack as the base unit.
14 Redundant Cascade Stacking Feature BayStack 400-ST1 Cascade Modules allo w you to connect up to 8 units into a red undant cascade stack. If any single unit fails or if a cable is accidently disconnected, other units in the stack remain o perational, without int erruption.
15 Figure 6. Redundant Cascade St acki ng Feature Unit 2 1 = Base unit 2 = Last unit 3 = Cascade cable (PN 303978-A) 4 = Cascade max-return cable (PN 303979-A) BS0035A Cascade A Out Cascade A In Unit .
16 Installation This secti on describes ho w to connect u p to eight BayStack 1 0/100/1000 Seri es switches into a red undant stack. The switch stack can consist of an y combination of BayStack 4 50-24T and Ba yStack 450-12T switch models. Before installing y our equipment, revie w the previous sections of this guide.
17 Installing the 400 -ST1 Cascade Module The Cascade Module slot on the BayStack 450 switch can accommodate a single 4 00-ST1 Cascade Module. T o install a 400-ST1 Cascade Module into the Cascade Module slot, follo w these steps: 1. Unplug the A C power cord fr om the back of the switch.
18 Figure 8. Installing a 400-ST1 Cascad e Module 4. Pr ess the m odule firmly into th e chas sis slot. B e sure that the module is fully seated into the mating connector . 5. Secure the module in the chass is by tightening the thu mb scr ews on t he modu le fr ont panel.
19 Installing and Connecting Multiple Switches The procedure to install an d connect multip le switches is similar for tabletop, shelf, or stand ard 19-in ch utility rack installation s. T o install multiple swit ches, follow these steps: 1. Install one unit at a time in the rack or on the sh elf or ta ble top .
20 5. Set the Unit Select switch f or the base unit to the Base (up = Ba se) positio n ( Figure 9 ). 6. Set the Unit Select switch f or all other units in the stack to th e Off (down = Off) position Only one unit in the stack can be the base unit. Figure 9.
21 7. Connect the units using the supplied cascade cables ( Figu re 10 ). a. Connect one end of a cascade cable to the Cascade A Out connector on th e Base Unit (unit 1).
22 b . Connect the other end of the cascad e cable to the cascade A In connector on the unit just below the base unit (un it 2), or just ab ove the base unit if cascading up t he stack. c. Continue attaching the cascade cables until the last unit is configured.
23 Connecting P ower When the stack is init ially po w ered up, the software automaticall y ass igns unit numb ers to the units (t he indi vidual switches in the stack). T he unit numbers correspond to the phys ical stack power up/initialization sequence, beginning wi th the base un it as unit 1.
24 One or tw o A C po wer strips may be req uired to accommodate the quantity of switches in the stack. 3. A pply power to the A C power strip. Set the A C power strip On/Of f switch to On (or connect th e AC power s trip to a groun ded A C po wer outlet).
25 Figure 11. V erifying the Instal lation • The Base LED f or the base un it only is on. If one (or more) Base LEDs ar e blinking, no unit (or more than on e unit) is configu red as the base unit. If the LEDs o n any of the units in the stack are not as shown in F igure 11 , cycle the power to the stack and v erify the LEDs.
26 Modifying an Existing Stac k Configuration This section p r ovides e xam ples of how to mo dify an existing stack con figuration. T he examples assume the stack conf igur ation is operation al with connected stations.
27 Assigning a New Base Unit to the Stack T o assign a new base unit to the s tack, complete the fol lowi ng step s: 1. Set the U nit Select switch on the original base uni t to the Of f position. See Figur e 9 on page 20 for details ab ou t the Unit Select switch.
28 Adding Units to the Stac k This sect io n des cri b es ho w to add one or more un it s t o the middle of a stack or to the end of a stack. Adding Un its to the Mid dle of a Stac k T o add one or more units to th e middle of a stack, complete the following steps: 1.
29 For table top configu rations , te mpor arily move units 1 and 2 to allo w space for units 5 an d 6. Figure 12. Adding to Middle of Sta ck 4. Add t h e ne w un its to t h e desir ed locat i o n. Fo r tabletop conf iguratio ns, replace units 1 an d 2 (tempor arily mov ed in Step 4).
30 5. Reconnect the cascade cable from unit 2 to the Cascade A In connector of (new) unit 5. 6. Connect a cascade cable from the C ascade A Out connector of unit 5 to the Cascade A In connector of unit 6 . 7. Connect a cascade cable from the C ascade A Out connector of unit 6 to the Cascade A In connector of unit 3 .
31 Figure 13. Adding to End of Stac k 2. Disconn ect the cascade max-retur n cable (item 4) fro m the Cascade A Out connector at unit 4. Leav e the other end o f the cascade max-return cable connected to the Cascade A In connector at unit 1. 3. Add the new units (units 5 and 6) to the end of th e stack con f igura tion.
32 4. Connect a cascade cable from the C ascade A Out connector of unit 4 to the Cascade A In connector of unit 5 . 5. Connect a cascade cable from the C ascade A Out connector of unit 5 to the Cascade A In connector of unit 6 . 6. Reconnect the cascade max-r eturn cable fr o m unit 1 to the Cascade A Out co n nector of unit 6.
33 Remo ving/Replacing Ad jacent Units T o remove/rep lace adjacent units from an oper at ing stack, complete the following steps (see Figu re 14 ): 1.
34 2. Remove the cascade cable fr om the Cascade A In connector at unit 5. 3. Remove the units (units 3 and 4) and in stall replacement units as r equ ired.
35 5. Repeat Steps 1 to 4 f or unit 5. Figure 15. Remo ving Nonadjacen t Units 6. Renu mber the order of the units fo r the new s tack configuration (if desired). Y ou can renumber the unit num bers as described in “Setting Up the Stack Conf iguration” in the Us ing the BayStac k 450 10/ 100/1000 Ser ies Switch gui de.
36 Upgrading the Ba yStac k 450 Swit ch Firmware The BayStack 450 switch firmwa re provides a code loa d facility that allows you to upgrade the f i rmware image ov er any switch port, in cluding any MD A ports. Y ou mu st upgrade th e BayStack 450 swit ch fi rmware image before y ou install the BayStack 400-ST1 Ca scade Module.
37 3. After the BayStack 450 boot co de im age is downl oaded, click on V ersion 1.1.0 at the BayS tack 450 agen t link. Fo llow t he prompts t o downloa d the BayStack 4 50 agent image. The ag ent image filename is b450110 2.img Be sure to downl oad the BayStack 45 0 boot code image first , then download the B ayStack 450 agent image.
38 • The port con nection to the load host canno t be throug h a MultiLink T runk. • During the load process, the ports are conf igured as follows: • T wi sted-pair ports: autonegotiation enabled. • Fiber optic ports: 100 Mb/s, half-dup lex. • Gigabit MD A po rt s: au tonegotiation dis abled, Preferred Ph y set to Right.
デバイスBay Technical Associates 400-ST1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bay Technical Associates 400-ST1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBay Technical Associates 400-ST1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bay Technical Associates 400-ST1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bay Technical Associates 400-ST1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bay Technical Associates 400-ST1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBay Technical Associates 400-ST1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bay Technical Associates 400-ST1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBay Technical Associates 400-ST1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。