Texas Instrumentsメーカー4Q 2006の使用説明書/サービス説明書
ページ先へ移動 of 49
T echnology for Innovators TM Interface Selection Guide 4Q 2006.
Interface Selection Guide T exas Instruments 4Q 2006 2 Interface Selection Guide T able of Contents ➔ Introduction 3 L VDS, xECL, CML . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Multipoint-L VDS (M-L VDS) .
T exas Instruments 4Q 2006 Interface Selection Guide T exas Instruments (TI) provides complete interface solutions that empower you to differentiate your products and accelerate time-to-market.
Interface Selection Guide T exas Instruments 4Q 2006 Literature Number Description Application Notes SCAA059 AC-Coupling Between Differential L VPECL, L VDS, HSTL, and CML SCAA062 DC-Coupling Between .
L VDS/L VPECL/CML Repeaters/T ranslators and Crosspoints Selection Guide No. No. Signaling Jitter Part-to- Tx tpd Rx ESD of of Input Output Rate Max Part T yp tpd T yp I CC HBM Pin/ Device 1 Descripti.
Interface Selection Guide T exas Instruments 4Q 2006 L VDS Selection Guide Signaling Part-to-Part Tx tpd No. of No. of Rate Skew Max T yp Device Description Tx Rx Input Signal Output Signal (Mbps) (ps) (ns) Single SN65LVDS1 Driver 1 — LVTTL L VDS 630 — 1.
T exas Instruments 4Q 2006 Interface Selection Guide L VDS, xECL, CML 7 ➔ L VDS Selection Guide R x I CC E SD Supply tpd T yp Max HBM V oltage Device (ns) (mA) (kV) (V) Pin/Package(s) Price * Single Family SN65LVDS1 — 8 15 3.3 8SOIC, 5SOP 0.47 SN65LVDS2 1 2.
Interface Selection Guide T exas Instruments 4Q 2006 100 Mbps 200 Mbps 300 Mbps 400 Mbps 500 Mbps 600 Mbps 700 Mbps Single Dual Quad 8-Channel 16-Channel L VDM179 L VDM180 L VDM176 L VDM050 L VDM051 L.
T exas Instruments 4Q 2006 Interface Selection Guide Multipoint-L VDS (M-L VDS) 9 ➔ M-L VDS Selection Guide No. No. Half/ Signaling Part-to- Tx tpd Rx tpd I CC ESD TIA/EIA-899 of of Rx Full Rate Par.
Interface Selection Guide T exas Instruments 4Q 2006 D esign Considerations Reliability — Best-in-class, high voltage and functional reliability with > 25 years. M agnetic Immunity — Immunity from external magnetic fields to prevent data corruption is a critical consideration for industrial applications.
T exas Instruments 4Q 2006 Interface Selection Guide D esign Considerations Interoperability — In general, RS-485 is a superset of RS-422. Compliance with the TIA/EIA standard will ensure reliable data communication in a variety of networks, including Modbus, INTERBUS, PROFIBUS, BACnet and a variety of proprietary protocols.
RS-485/422 Selection Guide S ignaling No. of Supply Rate ESD Receiver Dr/Rx (V) Enables Device 1 Features (Mbps) (kV) Fail-Safe Nodes Package(s) Price * DE, RE HVD12 3. 3V Su pp ly – L ow -S pe ed Sl ew- Ra te Co nt ro l 1 15 Short, Open, Idle 256 8-PDIP , 8-SOIC 1.
T exas Instruments 4Q 2006 Interface Selection Guide Personal video recorder application block diagram. RS232: IEC6100-4-2 (Level 4) ESD-Protected Devices T I offers new RS-232 devices with system- level IEC61000-4-2 electrostatic discharge (ESD) protection.
Interface Selection Guide T exas Instruments 4Q 2006 R S232 Selection Guide Data Rate ESD Supply I C C Device (kbps) Drivers Receivers HBM (kV) V oltage(s) (V) (max) (mA) Pin/Package(s) Price * MAX3223E 500 2 2 IEC61000-4-2 3.3, 5 1 20SOIC, 20SSOP , 20TSSOP , 24QFN 0.
T exas Instruments 4Q 2006 Interface Selection Guide RS-232 Selection Guide (Continued) Data Rate ESD Supply I CC Device (kbps) Drivers Receivers HBM (kV) Voltage(s) (V) (max) (mA) Pin/Package Price * SN75C1406 120 3 3 2KV HBM ± 12, 5 0.45 16PDIP , 16SO, 16SOIC 0.
Interface Selection Guide T exas Instruments 4Q 2006 Key Features • Single-, dual- and quad-channel devices • 16- and 64-byte FIFOs available • 5-, 3.
T exas Instruments 4Q 2006 Interface Selection Guide UART Selection Guide Asynchronous Communications Element with Autoflow Control The TL16C550D is a performance-enhanced version of TI’ s industry-standard TL16C550C single-channel UART with 16-byte FIFO.
Interface Selection Guide T exas Instruments 4Q 2006 D esign Considerations Bus Protection — Features such as short-circuit protection, thermal shutdown protection, glitch-free power -up and power -.
T exas Instruments 4Q 2006 Interface Selection Guide 1 2 3 4 5 6 7 8 9 * 0 # L CD Driver L VDS302 L VDS301 CLK D ATA Application P roce s sor with RGB V ideo Interface Flatlink™ 3G Number of Number .
Interface Selection Guide T exas Instruments 4Q 2006 Line Module Reference Clock DSP Controller Photo- diode Laser Diode TIA* MAC Framer/ Mapper PLL Multiplier NPU/ ASICs Clock Buffer Backplane SerDes Frontplane SerDes Clock Buffer Memory P A* LD* Power Management *TIA, P A and LD are in development and not currrently available.
T exas Instruments 4Q 2006 Interface Selection Guide SerDes (Serial Gigabit T ransceivers) Selection Guide Device Function Data Rate Serial I/F 1 Parallel I/F Power Special Features Price * General Purpose TLK1501 Single-Ch. 16:1 SerDes 0.6-1.5 Gbps 1 CML 16 LVTTL 200 mW Built-In T estability 8.
PanelBus™ (DVI) T ransmitters and Receivers V oltage Recvr ./T rans. Parallel Data Speed I CC Device (V) Channels Outputs (Mbps) (mA) Package Description Price * TFP401 3.3 3 48 495 400 100 HTQFP DVI receiver , 165 MHz 4.00 TFP401A 3.3 3 48 495 400 100 HTQFP DVI receiver , 165 MHz, HSYNC jitter immunity 4.
T exas Instruments 4Q 2006 Interface Selection Guide PanelBus™ HDCP Digital Receiver T FP501, TFP503 Get datasheets at: www .ti.com/ TFP501 or www.ti.com/ TFP503 The TFP501 and TFP503 are TI PanelBus flat panel display products, part of a comprehensive family of end-to-end DVI 1.
Interface Selection Guide T exas Instruments 4Q 2006 TMDS (for HDMI and DVI) T ransition Minimized Differential Signaling ( TMDS) is the electrical level standard used to transmit Digital Visual Interface (DVI) and High-Definition Multimedia Interface (HDMI) data.
Universal Serial Bus (USB) T he USB standard defines a bus product that r equ ires a host controller and enables plug- a nd-play connectivity . The most recently r eleased final specification, USB 2.0, defines high speed and allows complete backward compatibility with USB 1 .
Literature Number Description Application Notes SLLA122 Selection and Specification of Crystals for T exas Instruments USB 2.0 Devices SLLA154 VIDs, PIDs and Firmware: Design Decisions When Using TI U.
T exas Instruments 4Q 2006 Interface Selection Guide VIN/SW1 LDO_EN EN1 SW2 EN2 GND LDO_OUT LDO_ADJ OC1 OUT1 OUT2 OC2 TPS2145/55 TSSOP-14 LDO VIN/SW1.
Interface Selection Guide T exas Instruments 4Q 2006 USB High-Power Peripheral Bus Switch + LDO Device Switch V oltage Description TPS2140 3.3 V 3.3-V , 500-mA switch with active-low enable, 250-mA LDO TPS2141 5.0 V 5.0-V , 500-mA switch with active-low enable, 250-mA LDO TPS2150 3.
T exas Instruments 4Q 2006 Interface Selection Guide Design Considerations PCI Express ® takes the best features and ideas behind PCI and combines them with more than 10 years of industry “lessons learned. ” The result is a robust, scalable, flexible, cost-effective I/O interconnect that will serve the industry for the next 10-15 years.
Interface Selection Guide T exas Instruments 4Q 2006 TI’ s PCI Express bridge chip, the XIO2000A, is an industry first. It is designed for seamless migration from the legacy PCI to the PCI Express interface. It bridges an x1 PCI Express bus to a 32-bit, 33/66-MHz PCI bus capable of supporting up to six PCI devices downstream.
T exas Instruments 4Q 2006 Interface Selection Guide x1 PCI Express ® to 1394a OHCI Bridge XIO2200A Get samples, datasheets, EVMs and app reports at: w ww .ti.com/sc/device/ XIO2200A Key Features • x1 PCI Express Primary Interface • Supports two 1394a ports • Fully-Compliant with 1394 Open Host Controller Interface Specification, Revision 1.
Interface Selection Guide T exas Instruments 4Q 2006 The XIO1100 is a PCI Express PHY , compliant with the PCI Express Base Specification Revision 1.1 that interfaces the PCI Express Media Access Layer (MAC) to a PCI Express serial link.
T exas Instruments 4Q 2006 Interface Selection Guide Design Considerations Peripheral Component Interconnect (PCI) is an interconnection system between a micro- processor and attached devices in which expansion slots are spaced closely for high- speed operation.
Interface Selection Guide T exas Instruments 4Q 2006 T PS2211A • Fully integrated V C C and V P P switching for s ingle-slot PC card interface • Low r DS(on) • 3.3-V low-voltage mode • Short-circuit and t hermal protection • Compatible with 3.
T exas Instruments 4Q 2006 Interface Selection Guide Selection Guide Number I O S r D S(on) V I N Range Supply Current OC Logic OT Logic Device of FET s (min) (A) (m Ω ) (V) (µA) Output Output Enable Predecessor Price * Current-Limiting Power Switch ICs TPS2010A 1 0.
Interface Selection Guide T exas Instruments 4Q 2006 Design Considerations Physical-Layer Selection Issues • The 1394 PHY layer should support the minimum number of nodes or ports required by the end product. Having two ports permits spanning to other devices on the bus through daisy-chaining.
T exas Instruments 4Q 2006 Interface Selection Guide T echnical Information (Continued) • Applications of the cable version are the integration of I/O connectivity of personal computers, peripherals, and consumer electronics using a low-cost, scalable, high-speed serial interface.
Interface Selection Guide T exas Instruments 4Q 2006 Key Features • Compliant with IEEE 1394b-2002, IEEE 1394a-2000 and 1394-1995 standards • 3 Bilingual 1394 Ports • • 1394b (Beta) Mode at s400 and s800 • • 1394a (Data Strobe -DS) Mode at s100, s200 and s400 • Interoperable with link layer controllers using 3.
T exas Instruments 4Q 2006 Interface Selection Guide Conn. Conn. Conn. Conn. Conn. Conn. Rcvr Rcvr Rcvr Rcvr Rcvr Rcvr 22 Ω 22 Ω V TT V TT 0.25" 0.25" .94" .94" .94" .94" Z 0 † Z 0 ¥ † Unloaded backplane trace natural impedance (Z 0 ) is 45 Ω to 60 Ω, with 60 Ω being ideal.
Interface Selection Guide T exas Instruments 4Q 2006 GTLP Selection Guide Device Description Price* SN74GTLP1394 2-Bit LVTTL-to-GTLP Adjustable-Edge-Rate Bus Xcvr w/ Split L VTTL Port, Feedback Path and Selectable Polarity 2.
T exas Instruments 4Q 2006 Interface Selection Guide Parameter Name SN74VMEH22501 SN74VMEH2501A V oltage Nodes (V) 3.3 3.3 V CC Range (V) 3.15 to 3.45 3.15 to 3.45 Input Level LVTTL L VTTL Output Level LVTTL L VTTL Output Drive (mA) –48/64 –48/64 No.
Interface Selection Guide T exas Instruments 4Q 2006 Clock Selection by Speed and Signaling T ype Clock Selection by Number of Outputs and Signaling T ype 42 Clock Distribution Circuits ➔.
T exas Instruments 4Q 2006 Interface Selection Guide T he following products have similar functionality: Part Number TI Replacement AGERE BDG1A TB5D1M B DG1A TB5D2H B DGLA TB5D2H B PNGA TB5D1M B RF1A .
Interface Selection Guide T exas Instruments 4Q 2006 P art Number TI Replacement LINEAR TECHNOLOGY CORP . (L TC) (cont.) L T1785 SN75LBC184* L TC1472 TPS2211A L TC1480 SN75HVD11* L TC1481 SN75LBC176A*.
T exas Instruments 4Q 2006 Interface Selection Guide The following products have similar functionality: Part Number TI Replacement MICREL MIC2505 TPS2024/34 MIC2506 TPS2042A/52A MIC2507 TPS2044A/54A M.
Interface Selection Guide T exas Instruments 4Q 2006 The following products have similar functionality: Part Number TI Replacement P ERICOM (cont.) PI90LVT9637 SN65L VDT9637B* PI90LV017A SN65L VDS1* P.
Interface Selection Guide T exas Instruments 4Q 2006 Device Index 47 ➔ Device Page Device Page Device Page Device Page Device Page Device Page 1 75 . . . . . . . . . . . . . . .9, 12, 42 1 76B . . . . . . . . . . . . . . . . . .12 A DM2209E . . . . .
PRSRT STD U.S. POST AGE P AID DALLAS, TEXAS PERMIT NO. 2758 SSZT009C T exas Instruments Incorporated 14950 F AA Blvd. Fort Worth, TX 76155-9950 Address service requested TI W orldwide T echnical Support Internet T I Semiconductor Product Information Center Home Page support.
IMPORT ANT NOTICE T exas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice.
デバイスTexas Instruments 4Q 2006の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Texas Instruments 4Q 2006をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはTexas Instruments 4Q 2006の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Texas Instruments 4Q 2006の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Texas Instruments 4Q 2006で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Texas Instruments 4Q 2006を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はTexas Instruments 4Q 2006の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Texas Instruments 4Q 2006に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちTexas Instruments 4Q 2006デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。