CF-80 Continuous Flow Seed T reater Installation and Operation Manual.
This page intentionally left blank.
T OC 3.0 T able of Contents Gener al Categories 4.0 - Installation, General Calibration & Seed Calibration Calibr ation 5.0 - Calibration & P riming the Pump Oper ation 6.0 - Operation Appendix 7.0 - Maintenance 8.0 - Service T ips, Pump Checklist & T roubleshooting 10.
4.0 General Introduction General Calibration The CF-80 seed treater can be easily calibrated. Determine the type of seed to be treated. Although the CF-80 can treat up to 80 bushels per hour of soybean seed, other types of seed may not ow through the treater as freely; therefore capacity may vary .
Calibration 5.0 Calibration & Pump P riming 1. R ead the entire chemical label and MSDS to make sure you under stand the usage and rates to be applied. T ake special note whether the recommended application rate of the chemical is given in uid ounces per bushel or in uid ounces per cwt.
6.0 Calibration Calibration & Pump P riming If more than the required volume of chemical is obtained, adjust the speed control knob to a lower setting and rerun the calibration check. Continue this operation until the proper rates are being measured.
Maintenance 7.0 Maintenance When you are nished treating seed, disconnect the discharge tubing from the elbow tting and place it into your original chemical container .
8.0 Service Service T ips 1. Make sure ball valve is in ON position. 2. Check tightness of intake line tting - use pliers if necessary . Make sure there are no air bubbles in the line. 3. Check discharge hose for any chemical buildup. 4. Make sure the pump hose is in the correct position.
Appendix.
10.0 Guidelines GUIDELINES FOR HANDLING SEED-APPLIED PRODUCTS AND RECOMMENDED EQUIPMENT INSPECTION AND MAINTENANCE PROCEDURES The following are general recommendations for handling seed-applied products, equipment inspection and maintenance on most Gustafson application equipment used in commercial treating facilities.
Guidelines 11.0 Gener al Equipment • Check lters daily at least once. Clean rinse off as necessary . The lter assemblies are intended to keep agglomerates, plant debris and other foreign substances from going through the system and plugging lines.
12.0 W arranty LIMITED W ARRANTY , LIMIT A TION OF LIABILITY & CLAIMS Bayer CropScience warrants that the Gustafson application equipment shipped hereunder shall be free of defects in materials or work- manship for a period of one (1) year from the date of delivery .
This page intentionally left blank.
Bayer CropScience 4895 12th Avenue East Shakopee, Minnesota, 55379 USA www .bayercropscienceus.com.
デバイスBayer HealthCare CF-80の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bayer HealthCare CF-80をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBayer HealthCare CF-80の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bayer HealthCare CF-80の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bayer HealthCare CF-80で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bayer HealthCare CF-80を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBayer HealthCare CF-80の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bayer HealthCare CF-80に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBayer HealthCare CF-80デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。