W ARNING Improper installation, adjustment, alteration, service or maintenance can cause serious in- jury or property damage. Refer to this manual. For assistance or additional information, con- sult a qualified installer or service agency .
Page 2 Oil-Fired BCS Storage Capacity (gal.) BTUH (Thousands) Firing Rate (GPH) Hot Outlet T emperature Rise (F) OIL-FIRED BCS Instr uction Manual Return Cold Inlet Recovery (GPH) B D 20e-BCS 20 60 0.
Oil-Fired BCS Page 3 WHEN YOU RECEIVE Y OUR NEW W ATER HEA TER Check the new equipment to see if all components are in good condition and were not damaged in shipment. The water heater and burner may be shipped as separate units. The aquastat and immersion well are packed with the burner .
Page 4 Oil-Fired BCS 1. Cut a 7" O.D. opening in the preferred wall and provide a minimum of 1 ⁄ 2 " clearance of non-combustible space around the Balanced Flue. The opening should allow for a 1 ⁄ 2 " downward pitch to the outside for drainage of any condensate in the Balanced Flue.
Oil-Fired BCS Page 5 CONNECT W ATER PIPING Be careful not to apply any heat to the water heater nipples. Install dielectric unions and shut off valves on both hot and cold water lines. 40 BCS models are equipped with a brass inlet bushing in- stalled in the tank.
Page 6 Oil-Fired BCS FRESH AIR INTAKE VENT Proper sealing of the fresh air intake vent material is important, but temperature is not an issue. Failure to properly seal the inlet venting subjects the burner to possible reverse drafts after burner shutdown— a hazardous condition with the possibility of creating a fire .
Oil-Fired BCS Page 7 CONNECT THE OIL LINE Gravity System: The oil burner is normally equipped with a single-stage pump equipped for one line (gravity) flow . Use 3 ⁄ 8 " O.D. or larger soft copper tubing and attach with flared fittings. DO NOT USE COMPRESSION FITTINGS.
Page 8 Oil-Fired BCS PLA CE W A TER SYSTEM IN OPERA TION 1. Fill the tank with water , opening a hot water faucet to allow trapped air to escape from the heater . Open the cold water inlet valves. Shut off each faucet as it delivers water that is free of air .
Oil-Fired BCS Page 9 MEASURING THE OUTCOMING W ATER TEMPERA TURE, CON’T W ARNING: Hydr ogen gas can be produced in a hot water system served by a heater that has not been used for a long period of time (generally two weeks or more). Hydr ogen gas is extremely flammable.
SERVICE 1. Check the fuel supply , electrical wiring, fuses, and make sure the temperature control is calling for heat. 2. If the motor runs but there is no flame, remove the electrode assembly , clean, readjust, and check the porcelain for cracks. Replace if necessary .
Oil-Fired BCS Page 11 COMP ANY’S RESPONSIBILITY The company’ s responsibility is to repair or replace, at our option, with the prevailing compa- rable Bock model, any part of the equipment, includ.
OUR TO T AL W ARRANTY COMMITMENT W e will not assume, nor authorize any person to assume for us, any other liability in connec- tion with the sale or operation of Bock W ater Heaters.
Oil-Fired BCS Page 13 BOCK OIL-FIRED W ATER HEA TER.
Page 14 Oil-Fired BCS Balanced Flue ™ BURNER WIRE DIA GRAM Models 20, 32,40,51,120,190E-BCS Carlin EZ-T emp Control.
Oil-Fired BCS Page 15 EXP ANSION T ANK (OPTIONAL) IF ANY OF THESE DEVICES ARE USED, A PROPERL Y SIZED EXP ANSION T ANK MUST BE INST ALLED..
Page 16 Oil-Fired BCS Form # 23390 Rev 3 3/2007 BCS AND RADIANT HEA T Radiant heating: An in-floor hot water space heating system A Bock high-efficiency water heater and zoned radiant heating— Bock&Radiant —make perfect partners for cost-effective personal comfort that heats both space and water .
デバイスBCS Oil-Firedの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
BCS Oil-Firedをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBCS Oil-Firedの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。BCS Oil-Firedの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。BCS Oil-Firedで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
BCS Oil-Firedを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBCS Oil-Firedの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、BCS Oil-Firedに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBCS Oil-Firedデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。