OPERA TING INSTRUCTIONS MUL TICHANNEL POWER AMPLIFIERS DA-550F CU DA-500F-HL CU Thank you for purchasing TOA's Multichannel Power Amplifier. Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.
2 1. IMPORT ANT SAFETY INSTRUCTIONS • Read these instructions. • Keep these instructions. • Heed all warnings. • Follow all instructions. • Do not use this apparatus near water. • Clean only with dry cloth. • Do not block any ventilation openings.
3 When Installing the Unit • Do not expose the unit to rain or an environment where it may be splashed by water or other liquids, as doing so may result in fire or electric shock. • Use the unit only with the voltage specified on the unit. Using a voltage higher than that which is specified may result in fire or electric shock.
4 • The unit is designed exclusively to be mounted in an equipment rack. Be sure to follow the instructions below when rack-mounting the unit. Failure to do so may cause a fire or personal injury. · Install the equipment rack on a stable, hard floor.
5 5. HANDLING PRECAUTIONS • Keep the input cable away from the output cable. If installed close to each other, oscillation could occur. • To avoid unit failures, never connect outputs of 2 or more units in parallel. • Only connect speakers with an impedance equal to or greater than those specified.
6 6 7. NOMENCLA TURE AND FUNCTIONS [Front] 1 2 3 4 5 DA-550F DA-500F-HL 1. Power switch [ ON/OFF] Power is switched on and off with each depression of this switch. 2. Power indicator [POWER] Lights blue when the power is switched on. 3. Input level controls [CH 1/BRIDGE 1, CH 2, CH 3/BRIDGE 2, CH 4] Adjust the input level of each channel.
7 7 [Rear] DA-550F 6 7 9 12 DA-500F-HL 6 7 12 13 9 8 8 9 9 11 10 10 11 10 10 6. AC power cord (2 m or 6.56 ft) The socket-outlet shall be installed near the equipment and the plug (disconnecting device) shall be easily accessible.
8 11. CH 1 mode ON/OFF switch [CH 1 TO ALL, ON / OFF] Setting this switch to ON (pressed in) transmits the Channel 1 input signal to all channels. Output signal levels can be individually adjusted with each channel's input level control (3). Note Be sure to first turn off the power switch when changing the CH 1 mode switch settings.
9 Step 1. Switch off the unit's power. Step 2. Set the BRIDGE ON/OFF switches and CH 1 mode ON/OFF switch. Step 3. Set the HPF ON/OFF switch. (DA-500F-HL only) HI-PASS: –6 dB/oct, cut off frequency 50 Hz FLAT: OFF Step 4. Connect the sound source equipment to the Input terminals.
10 Switch BRIDGE 1 BRIDGE 2 CH 1 mode ON ON ON Setting CH1 CH1 CH2 CH3 CH4 BRIDGE 1 BRIDGE 2 Speaker output terminals 8 Ω - + - + [1 input - 2 outputs] 8 Ω DA-550F 16 – 19.
11 CH1 - + CH2 - + Speaker output terminals Switch BRIDGE 1 BRIDGE 2 CH 1 mode OFF ON OFF Setting 4 – 8 Ω 4 – 8 Ω 8 Ω CH1 CH2 CH3 CH1 CH2 CH3 CH4 BRIDGE 2 - + [3 inputs - 3 outputs (1) ] DA-550F 4 – 9.
12 Connector connections Step 1. Loosen the terminal screw, then insert the cable. Step 2. Retighten the terminal screw. (Pull on the cable to ensure it is securely connected.) Tip Recommended slotted screwdriver type: Screwdriver with blade that is 3 mm (0.
13 1 1. PROTECTION OPERA TION LIST Failure Protection Operation Indicator Remedy Recovery Overcurrent due to overload Current limiter activated when impedance drops below the specified value. Peak indicator lights. Remove overload. Connecting a correct load automatically restores normal operation.
14 13. CLEANING THE FIL TER Step 1. Switch off the unit's power. Step 2. Remove the ventilation panel as shown in the figure. Step 3. Detach the filter inside the ventilation panel. Step 4. Clear the filter of dust. Step 5. Replace the filter and ventilation panel.
15 15. BLOCK DIAGRAMS 15.1. DA-550F H C CH 1 INPUT E H C CH 2 INPUT E Current Limiter Short Detector Protection Circuit OUTPUT 1 relay CH 1 OUTPUT CH 2 OUTPUT +4 dB - 10 dB CH 1 sensitivity selection .
16. HOW TO USE THE CONTROL/MONIT OR TERMINALS The Control/Monitor terminals on the rear panel permit power ON/OFF control of the individual channels and monitoring for the power ON/OFF status and protection status on each channel, and fan operation status.
16.3. About Pin 7 of the Control/Monitor T erminals A ground common to all the control and monitor terminals is assigned to Pin 7. Both Pins 7 of the Control/Monitor terminal for CH1 and CH2, and that for CH 3 and CH4 are internally connected to each other.
16.6. RJ45 Connector's Pin Arrangement and Cable Color Codes Category 5 twisted pair cable for LAN (CAT5-UTP) RJ45 pin No. To Control/Monitor terminal 1 2 5 6 3 4 7 8 RJ45 pin No.
19 * 0 dB = 0.775 V Note: The design and specifications are subject to change without notice for improvement. Removable terminal plug (3 pins) ........................................ 4 Tamper-proof cap ................................................
133-22-102-60 URL: http://www.toa.jp/ * 0 dB = 0.775 V Note: The design and specifications are subject to change without notice for improvement. Removable terminal plug (3 pins) ........................................ 4 Tamper-proof cap .............
デバイスToa DA-500F-HL CUの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Toa DA-500F-HL CUをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはToa DA-500F-HL CUの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Toa DA-500F-HL CUの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Toa DA-500F-HL CUで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Toa DA-500F-HL CUを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はToa DA-500F-HL CUの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Toa DA-500F-HL CUに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちToa DA-500F-HL CUデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。