This Manual Cover Models: FPS1000-12 FPS1000-24 FPS1000-32 FPS1000-48 FPS-S1U 19” Rack Single Output FPS-T1U 19” Rack T riple Output FPS SERIES 1000W In 1U Fr ont End P o wer Supplies INSTR UCTION.
FPS1000 SERIES INSTRUCTION MANUAL DWG NO: IA599-04-02 A.
T ABLE OF CONTENTS W arranty ...................................................................................................................... ...........Pg. 1 FPS1000, FPS-S1U and FPS-T1U rack Safety instructions ................................
1 W ARRANTY This Densei-Lambda product is warranted against defects in materials and workmanship for a period of two years from date of shipment. During the warranty period , Densei-Lambda will, at it's option, either repair or replace products which prove to be defective.
2 FPS1000 POWER SUPPL Y AND FPS-S1U RACK SAFETY INSTRUCTIONS IMPORT ANT SAFETY INSTRUCTIONS Operating personnel must not remo ve the FPS1000, FPS-S1U and the FPS-T1U cov er . No internal adjustment or component replacement is allowed by non Densei-Lambda qualified service personnel.
3 FPS1000 Instruction Manual A TTENTION: Risque de choc et de danger e'lectriques. Le de'branchement d'une seule alimenttation stabilise'e ne de'branche uniquement qu'un module "Alimentation Stabilise'e".
4 CHAPTER 1 FPS1000 SERIES SPECIFICA TIONS Model FPS1000 FPS1000 FPS1000 V/I -24 -32 -48 24 32 48 29 38.4 58 33 26 17.25 40 31 21 V1 (V) V2 (V) I1 (A) I2 (A) V1 V2 Fig. 1: Rated output current vs output v oltage V out (V) I1 Iout (A) I2 Notes: *1: For cases where conf or mance to various safety standards (UL, EN etc.
5 CHAPTER 2 OUTLINE DRA WINGS 1.2 FPS 1000 SERIES OUTLINE DRA WINGS FPS1000 Instruction Manual.
6 2.2 FPS 1000/P SERIES OUTLINE DRA WINGS.
7 CHAPTER 3 FPS1000 POWER SUPPL Y INST ALLA TION 3.1 GENERAL This chapter contains instructions for initial inspection, preparation for use and repackaging forshipment. NOTE FPS1000 power supplies series generate magnetic field which might affect the operation of other instruments.
8 3.7 CONNECTING THE LOAD wire size Resistivity Maximum length in Feet to limit voltage A WG Ohm/kft drop to 1V or less. 5A 10A 20A 50A 150A 14 2.526 80 40 20 8 2 12 1.589 120 60 30 12 3.4 10 0.9994 200 100 50 20 6 8 0.6285 320 160 80 32 10 6 0.3953 500 250 125 50 16 4 0.
Fig. 3-2: FPS1000/P front panel 1 2 34 5 6 Fig. 3-1: FPS1000 front panel 1 4 5 3 2 9 3.7.6 Front panel controls and indicator 3.7.3 Noise and Impedance Effects T o minimize the noise pickup or radiation, the load wires and remote sense wires should be twisted-pairs of the shortest possible length.
10 3.7.7 Input/Output connector information The FPS1000 series uses male connector PCIB24W9M400A1, Positronic connector . T o mate FPS1000 series to the load circuitry , use female connector PCIB24W9F400A1-S1031, Positronic connector . Refer to T able 3-4 and to the Outline drawing in chapter 2 for the connector pinout description.
11 CHAPTER 4 FUNCTIONS AND FEA TURES 4.1 Input V oltage Range Input voltage is single phase 85~265V ac (47~63Hz). The power supply can be operated also with a DC input voltage, 120~330VDC but the safety approvals apply to the AC voltage only . Input voltage which is out of the specifications might cause damage to the unit.
12 4.8 DC_OK signal An open collector output provides a low output voltage detection signal. The open collector output is on when the output voltage is higher than 80%+/-5% of the rated output voltage of the power supply .
13 Fig 4-6 4.1 1 Remote Sensing The Remote sensing compensates voltage drop on the load wiring. The maximum voltage drop on each wire is 1V , however , it is recommended to minimize the voltage drop on the load wires to improve the response to load current changes.
14 Fig 5-1: single load connection, local sensing Fig 5-2: Remote sensing, single load. CHAPTER 5 BASIC CONNECTIONS FOR OPERA TION 5.1 Connecting single load, Local sensing Local sensing is suitable for applications where load regulation is not critical.
15 Fig 5-4: Multiple loads connection with distribution terminal 5.4 Multiple loads connection with distribution terminals If remotely located output distribution terminals are used, the power supply output terminals should be connected to the distribution terminals by a pair of twisted or shielded wires.
16 CHAPTER 6 P ARALLEL AND SERIES OPERA TION 6.1 Parallel operation Up to 8 FPS1000 units of the same output voltage rating can be connected in parallel. By connecting the CS signal between the paralleled units, automatic current balance is achieved, with +/-10% accuracy .
17 Fig 6-3: Signal Return connection at parallel operation Fig 6-4: Remote On/Off control at parallel operation 6.1.3 Signal Return bus at parallel operation The Signal Return of each paralleled unit can be connected together to form a common Signal Return bus.
18 Fig 6-6: Series connection for Bipolar output voltage 6.2 Series operation T wo units can be seriesly connected to increase the output voltage or to create a bipolar voltage source. It is recommended to connect diodes in parallel with each output to prevent reverse voltage in case of failure in one of the power supplies.
19 FPS1000 Instruction Manual 7.2 I 2 C Interface Specifications 7.2.1 General specifications 1. Clock frequency: 100KHz 2. Address lines: Three (A0, A1, A2). Support 8 power supply modules 7.2.2 Output voltage measurement 7.2.3 Output current measurement 7.
20 PCF8574 slave address: T able 7-2 7.3 Block diagram of the I 2 C option Refer to Fig 7-1 for description of the I 2 C block diagram and for typical application.
21 The PCF8591 slave address is: The PCF8591 device initially requires a control byte to be written to the configuration register . The control byte is as follows: When a single channel is to be read, A,B,C and D should be determined as follows: Refer to the following table for the scaling of the A/D channels: 7.
22 Internal temperature calculation example: 1. Hex readback: 68 (01 10 1000). 2. Convert hex readback to decimal: 104 3. Calculate the measured temperature: T emp=104*0.
23 Fig 8-1: Expected fan life vs. ambient temperature CHAPTER 8 FPS1000 MAINTENANCE 8.1 Introduction This chapter contains information about maintenance, calibration and troubleshooting of the FPS1000 power supply .
24 FPS-S1U 19” Rack Single Output.
25 CHAPTER 9 FPS-S1U RACK SPECIFICA TIONS FPS-S1U Instruction Manual Notes: *1: The Output of all the FPS1000 modules are connected in parallel in the rac k. *2: F or input voltage lo wer than 100V ac, maximum output po wer derated by 10% of the po wer rating.
26 Step no Item Description Reference 1 Inspection Initial physical inspection of the power supply Section 3.3 2 Installation Installing the power supply . Section 10.4 Ensuring adequate ventilation. Section 10.5 3 AC source AC source requirements Section 3.
1 4 3 2 5 1 27 10.7.3 Making the load connections 10.7.4 Rear panel description Fig. 10-1: FPS-S1U Rear panel The load wires should be properly terminated with terminals securely attached. DO NOT use unterminated wires for load connection at the FPS-S1U.
28 10.7.5 Control and monitoring signals connector Current sharing signal. When FPS-S1U racks are connected in parallel, the CS pins of the units should be connected to allow current balance between units. CS 9 Connection for output voltage trimming of FPS1000 unit "C".
29 Fig 10-2: FPS1000 modules location 10.7.6 Modules location Up to three FPS1000 modules of the same output voltage rating can be plugged into an FPS-S1U rack. Refer to Fig 10-2 for the modules location. 10.7.7 Blank panels Each FPS-S1U rack is supplied with two blank panels in the package.
30 CHAPTER 1 1 FPS-S1U AND FPS-S1U/P OUTLINE DRA WINGS 1 1.1 FPS-S1U Outline Drawing.
31 1 1.2 FPS-S1U/P Outline Drawing FPS-S1U Instruction Manual.
32 Fig 12-1: single load connection, local sensing Fig 12-2: Remote sensing, single load. Fig 12-3: Multiple loads connection with distribution terminal CHAPTER 12 BASIC CONNECTIONS FOR OPERA TION FPS-S1U RACK 12.1 Connecting single load, Local sensing Local sensing is suitable for applications where load regulation is not critical.
33 Fig 12-4: Individual On/Off control Fig 12-5: Single On/Off control Fig 12-6: Output voltage trimming Fig 12-7: Supervisory signals 12.4 On/Off control Fig 12-4 shows typical connection for individual On/Off control of each installed FPS1000 unit. The On/Off control signal is applied to the DB25 connector located at the rear panel (refer to sec.
34 CHAPTER 13 P ARALLEL AND SERIES OPERA TION 13.1 Parallel operation Up to 3 FPS-S1U racks with up to 8 FPS1000 installed units of the same output voltage rating can be connected in parallel. The built-in Oring diodes on the main output and on the +12V auxiliary voltage in each FPS1000 unit allow N+1 operation.
35 Fig 13-3: Output voltage trimming at parallel operation Fig 13-4: Signal Return connection at parallel operation 13.1.2 Output voltage trimming at parallel operation The output voltage of the units connected in parallel can be made by a single trimmer or resistive divider .
36 Fig 13-5: Remote On/Off control at parallel operation Fig 13-6: Series connection for increased output voltage 13.1.4 Remote On/Off control at parallel operation The paralleled racks can be turned On or Off via a single On/Of f control. Refer to Fig 13-5 for typical application.
37 CHAPTER 14 FPS-S1U I 2 C BUS INTERF ACE OPTION 14.1 Introduction The FPS-S1U rack provides access to the I 2 C Bus interface in each installed FPS1000/S unit via the rear panel DB25 female connector located at the rear panel. The Clock is connected to pin 20 and the Data is connected to pin 21.
38 CHAPTER 15 FPS-S1U MAINTENANCE 15.1 Introduction This chapter contains information about maintenance, calibration and troubleshooting of the FPS-S1U rack. 15.2 Units under warranty Units requiring repairs during the warranty period should be returned to Densei-Lambda authorized service office.
39 FPS-T1U 19” Rack T riple Output.
40 Notes: *1: The Output of all the FPS1000 modules are floating in the rac k. *2: F or input v oltage lower than 100V ac, maximum output pow er derated by 10% of the po wer rating. *3: F or cases where conf or mance to to various saf ety standards (UL, EN etc.
41 Step no Item Description Reference 1 Inspection Initial physical inspection of the power supply Section 3.3 2 Installation Installing the power supply . Section 10.4 Ensuring adequate ventilation. Section 10.5 3 A C source A C source requirements Section 3.
42 17.7.3 Making the load connections 17.7.4 Rear panel description Fig. 17-1: FPS-T1U Rear panel The load wires should be properly terminated with terminals securely attached.
43 17.7.5 Rear Panel In/Out Connector Pins Function Description J1(A), J2(B), J3(C) Pin No Function Description 14 TEMP_ALARM Open collector signal, ref erenced to pin 3 (Signal Retur n). On when the internal temperature of FPS1000 unit is within saf e limit, Off appro x.
44 Fig 17-2: FPS1000 modules location 17.7.6 Modules location Up to three FPS1000 modules can be plugged into an FPS-T1U rack. Refer to Fig 17-2 for the modules location. 17.7.7 Blank panels Each FPS-T1U rack is supplied with two blank panels in the package.
FPS-T1U Instruction Manual 45 CHAPTER 18 FPS-T1U AND FPS-T1U/P OUTLINE DRA WINGS 18.1 FPS-T1U Outline Drawing.
46 11.1 FPS-T1U Outline Drawing 18.2 FPS-T1U/P Outline Drawing.
47 Fig 19-1: Remote sensing, three load. CHAPTER 19 BASIC CONNECTIONS FOR OPERA TION FPS-T1U RACK 19.1 Connecting Single Load, Remote Sensing Remote sensing is used in cases where the load regulation is important at the load terminals. Use twisted or shielded wires to minimize noise pick-up.
48 Fig 19-4 shows typical output v oltage tr imming connection f or FPS1000 unit ‘A’ inside the rac k Units ‘B’ and ‘C’ connections - Refer to 17.7.5 Signals are accessible at the J1(A), J2(B), J3(C) connectors on the rear panel of the r ack Fig 19-5 shows typical connection f or FPS1000 unit ‘A’.
49 FPS-T1U FPS-1000 Module A FPS-1000 Module B FPS-1000 Module C J1(A)-12 J3(C)-3 ON/ OFF_1 A J2(B)-12 J2(B)-3 ON/ OFF_1 B J3(C)-12 J1(A)-3 ON/ OFF_1 C LOAD +V +S -S -V +S -S +V +S -S -V +S -S +S -S +V +S -S -V +S -S +V -V CS CS CS J1(C)-10 J1(B)-10 J1(A)-10 CHAPTER 20 P ARALLEL AND SERIES OPERA TION 20.
50 (*) Diodes are user supplied FPS-T1U FPS-1000 Module A FPS-1000 Module B FPS-1000 Module C J1(A)-12 J3(C)-3 ON/ OFF_1 A J2(B)-12 J2(B)-3 ON/ OFF_1 B J3(C)-12 J1(A)-3 ON/ OFF_1 C LOAD +V +S -S -V +S -S +V -V +V +S -S -V (*) (*) +V +S -S -V (*) 20.
51 CHAPTER 21 FPS-T1U I 2 C BUS INTERF ACE OPTION 21.1 Introduction The FPS-T1U rack provides access to the I 2 C Bus interface in each installed FPS1000/S unit via the rear panel MOLEX female connector located at the rear panel. The Clock is connected to pin 2 and the Data is connected to pin 1.
52 CHAPTER 22 FPS-T1U MAINTENANCE 22.1 Introduction This chapter contains information about maintenance, calibration and troubleshooting of the FPS-T1U rack. 22.2 Units under warranty Units requiring repairs during the warranty period should be returned to Densei-Lambda authorized service office.
53 Notes.
56 Notes.
デバイスTOA Electronics FPS1000-32の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
TOA Electronics FPS1000-32をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはTOA Electronics FPS1000-32の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。TOA Electronics FPS1000-32の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。TOA Electronics FPS1000-32で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
TOA Electronics FPS1000-32を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はTOA Electronics FPS1000-32の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、TOA Electronics FPS1000-32に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちTOA Electronics FPS1000-32デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。