TOA ElectronicsメーカーNX-100の使用説明書/サービス説明書
ページ先へ移動 of 114
INST ALLA TION SETUP MANUAL NETWORK AUDIO ADAPTERS NX-100 NX-100S Thank you for purchasing TOA's Network Audio Adapter. Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.
2 T ABLE OF CONTENTS 1. GENERAL DESCRIPTION ......................................................................................... 1-2 2. FEA TURES ....................................................................................................
3 2. SETUP SOFTW ARE CONFIGURA TION AND SETTING ITEMS .................. 3-3 3. SETTING PROCEDURE ............................................................................................. 3-4 4. ST ARTUP OF INST ALLA TION SETTING PROGRAM .........
4 1. OUTLINE OF SETTING USING BROWSER ........................................................ 4-2 2. SETTINGS ....................................................................................................................... 4-2 3. NETWORK SETTING .
5 1. EXPLANA TION 1.1. IP Network and Address ............................................................................................... 6-2 1.2. Network Address Translation (NAT) and Setup Software Programs ............................ 6-3 1.3. IP Broadcast and Unit Scan .
Chapter 1 BEFORE INST ALLA TIONS AND SETTINGS.
1-2 Chapter 1: BEFORE INSTALLATIONS AND SETTINGS 1. GENERAL DESCRIPTION TOA's NX-100/100S Network Audio Adapter is specially developed to transmit high-quality audio signals and such control data as serial data over IP networks such as LAN or Internet in real time.
00-05-F9-FF-80-81 NETWORK AUDIO ADAPTER NX-100S LNK/ACT FD/COL SIGNAL INPUT PEAK STATUS ERROR RUN RESET 1 2 3 4 5 6 7 8 9 1-3 Chapter 1: BEFORE INSTALLATIONS AND SETTINGS 3. NOMENCLA TURE AND FUNCTIONS [Front] 1. LNK/ACT Indicator (Green) Lights when the unit is connected to a network.
1-4 Chapter 1: BEFORE INSTALLATIONS AND SETTINGS [Rear] 10. Cord Clamp Pinches and securely holds the AC adapter cord to prevent its plug from detaching. 11. DC Power Input Terminal [DC INPUT] A 24 V DC input. 12. Functional Earth Terminal [SIGNAL GND] Hum noise may be generated when external equipment is connected to the unit.
1-5 Chapter 1: BEFORE INSTALLATIONS AND SETTINGS 20. Input Volume Control [INPUT VOLUME] Adjusts the audio input level. Turn the control clockwise to increase the level and counterclockwise to decrease it. Adjust the control so that the Input signal indicator (3) lights and the Input peak indicator (4) does not light.
1-6 Chapter 1: BEFORE INSTALLATIONS AND SETTINGS 4. SETTING T ASK FLOWS (1) Unit Installation and Connection Refer to Chapter 2, Unit and Software Installations . (2) Software Installation Install the setup program, operation program, and Java Runtime Environment in the personal computer (PC).
Chapter 2 UNIT AND SOFTW ARE INST ALLA TIONS.
2-2 Chapter 2: UNIT AND SOFTWARE INSTALLATIONS 1. CONNECTIONS 1.1. Power Source Connections 1.1.1. When using a 24V DC power source Connect a 24V DC power source to the unit's DC INPUT terminal.
2-3 Chapter 2: UNIT AND SOFTWARE INSTALLATIONS 1.2. T erminal Connections MIC LINE VOLUME INPUT 24V DC INPUT AUDIO OUTPUT FG 7 6 7 6 AUDIO INPUT 8C 5 4 3 2 1 C 8 5 4 3 2 1 CONTACT OUTPUT CONTACT INPUT.
2-4 Chapter 2: UNIT AND SOFTWARE INSTALLATIONS MIC LINE VOLUME INPUT 24V DC INPUT AUDIO OUTPUT FG 7 6 7 6 AUDIO INPUT 8C 5 4 3 2 1 C 8 5 4 3 2 1 CONTACT OUTPUT CONTACT INPUT RS-232C 200mA 10/100M HCE .
2-5 Chapter 2: UNIT AND SOFTWARE INSTALLATIONS 2. CONNECTIONS T O TERMINAL PLUGS Wire the removable terminal plugs for power input (NX-100 only), audio input and output, and control input and output a.
2-6 Chapter 2: UNIT AND SOFTWARE INSTALLATIONS 3. RACK MOUNTING Use the optional mounting hardware set when installing the unit in an equipment rack. Be sure to remove the rubber feet located on the unit's bottom surface before mounting. • Use the optional MB-15B-BK hardware set when mounting a single unit.
2-7 Chapter 2: UNIT AND SOFTWARE INSTALLATIONS 4. MAC ADDRESSES AND INST ALLA TION LOCA TIONS When making the unit's network settings, the unit's MAC address* must have a clear association with its corresponding installation location. Be sure to record the relationship during installation to facilitate later network settings.
2-8 Chapter 2: UNIT AND SOFTWARE INSTALLATIONS 5. SOFTW ARE INST ALLA TION 5.1. System Conditions The following minimum PC (personal computer) specifications are required in order to correctly operate the unit's software program. Notes • Windows is a trademark of Microsoft Corporation.
2-9 Chapter 2: UNIT AND SOFTWARE INSTALLATIONS 5.3. Installing Java Runtime Environment The following procedures do not need to be carried out if J2SE Runtime Environment,5.0 Update 3 has already been installed in the PC. Step 1. Quit other activated applications before installation.
2-10 Chapter 2: UNIT AND SOFTWARE INSTALLATIONS Tip Check the correct Runtime installation or version number from "Control Panel." Installation completion icon.
2-11 Chapter 2: UNIT AND SOFTWARE INSTALLATIONS 5.4. Installing the NX-100 Software The NX-100 software consists of the following 2 programs. • NX-100 Setup Program (Installation Setting) Enables integrated setting of the NX-100 and NX-100S from the PC.
2-12 Chapter 2: UNIT AND SOFTWARE INSTALLATIONS Step 3. When installing in a different folder from the one displayed, press the Change button to select the desired folder. Press the Next button if the currently displayed folder is correct. The "Setup Type" screen will be displayed.
2-13 Chapter 2: UNIT AND SOFTWARE INSTALLATIONS Step 4. Select the NX-100 software program to install, then press the Next button. Tip When installing simultaneously the NX-100 Setup Program (Installation Setting) and Operation Program, select "NX-100 Software Custom-Setup.
2-14 Chapter 2: UNIT AND SOFTWARE INSTALLATIONS Step 5. Press the Finish button when the indication "InstallShield Wizard Completed" is displayed after installation completion. Tip An icon for the installed NX-100 software program is created on the desktop.
2-15 Chapter 2: UNIT AND SOFTWARE INSTALLATIONS 5.4.3. Installation folder configuration The installed software program is stored by default in C:Program FilesTOANX-100.
Chapter 3 SYSTEM SETTINGS (NX-100 SETUP PROGRAM).
3-2 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) 1. GENERAL DESCRIPTION 1.1. What is the NX-100 Setup Program? This program is used to set all the NX-100 and NX-100S units connected to a LAN. It also provides a simple display on the PC screen of operating data for multiple NX-100 and NX-100S units connected to a LAN.
3-3 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) 2. SETUP SOFTW ARE CONFIGURA TION AND SETTING ITEMS The Installation Setting Program permits settings of all items including unit scanning and network setting. First set all items using this software at the time of system installation.
3-4 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) 3. SETTING PROCEDURE Pattern 1: Initial On-Site Setup (1) Unit Scanning (Network Setting) • After scanning the unit using the Setup program's Unit Scanning Tool, set the IP address, default gateway, subnet mask, and unit name.
3-5 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) Pattern 2: Uploading the programmed system setting file after scanning the connected units on-site. (1) System Setting Using the System Setting Tool, program all the units in the system, and enter their unit names and IP address numbers.
3-6 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) 4. ST ARTUP OF INST ALLA TION SETTING PROGRAM Step 1. Either double-click on the Installation Setting Program icon that was created on the desktop during installation or directly double-click on the application [nx100_util.
3-7 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) Step 4. Click on [System Setting] when performing such system settings as broadcast configuration. Tip When the settings are saved, a unit setting file is automatically created for each individual IP address and saved in the data folder.
3-8 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) 5. UNIT SCANNING T OOL Scans the units connected to the LAN. Setting data can only be uploaded into the NX-100S and NX-100 units after each unit's IP address has been correctly set by way of either the Installation Setting Program's Unit Scanning Tool or a browser.
3-9 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) 5.2. Menu 5.2.1. File Save in setting file format (Ctrl+S): Saves scanned unit data to the PC in unit setting file format ([IP address].
3-10 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) 5.2.3. Help Help: Displays help contents. Version data: Indicates the version of the program in use. 5.3. Buttons (1) (2) (1) Unit scan button: Scans all the units on the LAN. (2) Setting upload button: Writes the IP address, subnet mask, default gateway, and name into the selected units.
3-11 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) 5.5. Changing the Unit Setting V alues Change the unit's setting values individually. Step 1. Double-click on the desired cell. Data can be entered. Step 2. Enter a new value. Step 3. Press the Enter key or click on another cell.
3-12 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) 5.7. Subnet Mask and Default Gateway Settings The same subnet mask and default gateway numbers can be set for all selected units. Step 1. Tick the selection checkbox to select the unit. To select all units, select [Scan] → [Select all].
3-13 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) 6. SYSTEM SETTING T OOL Setting data can only be updated after the unit's IP address has been correctly set by way of either the Installation Setting Program's Unit Scanning Tool or a browser.
3-14 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) 6.2. Menu 6.2.1. File Save to file (Ctrl+S): Overwrites and saves the system setting file. Reopen file (Ctrl+O): Rereads the saved system setting file. Log file download: Saves the log of all NX-100 and NX-100S operations programmed into the system.
3-15 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) 6.2.5. Buttons (1) Save button: Saves and overwrites the system setting file. (2) NX-100 Add button: Adds NX-100 units to the network list (edit screen). (3) NX-100S Add button: Adds NX-100S units to the network list (edit screen).
3-16 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) 6.3. Network Setting Step 1. Click on the [Network] tab of the System Setting Tool. The setting screen will be displayed.
3-17 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) [Start port No.] Enter the base number of the TCP port (other than web server, which is used by the unit).
3-18 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) 6.4. Broadcast Spec Setting Step 1. Click on the Broadcast Spec tab of the System Setting Tool. The setting screen will be displayed. Step 2. Select the usable bandwidth at Navigator. Selection of the usable bandwidth automatically sets recommended values except those related to Multicast.
3-19 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) (2) Packet size Select the size of audio packet. The packet size cannot be changed when [Resend] is selected in the Packet loss recovery item. Smaller packet sizes result in a wider bandwidth, however delay times become shorter.
3-20 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) 6.5. Broadcast Pattern Setting 6.5.1. Setting new broadcast patterns Step 1. Click on the [Broadcast Pattern] tab of the System Setting Tool.
3-21 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) Step 2. Press the Add button. The edit area becomes available for editing. Up to 20 patters can be set for each unit. Step 3. Enter a broadcast pattern name. Caution Avoid assigning a name already programmed.
3-22 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) 6.5.2. Editing broadcast patterns Step 1. Click on the [Broadcast Pattern] tab of the System Setting Tool. The setting screen will be displayed. Step 2. Click on the broadcast pattern to be edited.
3-23 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) 6.6. Contact Setting 6.6.1. Contact input setting Step 1. Click on the [Contact] tab of the System Setting Tool. Step 2. Click on the selection button for the contact input channel number. The setting contents will be displayed.
3-24 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) Step 4. Set the type to [Momentary] or [Latch]. Momentary: The designated broadcast pattern or other unit's contact output is activated during the interval that input is ON. Activation stops while the input is OFF.
3-25 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) 6.6.2. Contact output setting Step 1. Click on the [Contact] tab of the System Setting Tool. Step 2. Click on the selection button for contact output channel numbers. The setting contents will be displayed.
3-26 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) Step 5. Set the type to [Momentary] or [Latch]. Momentary: Provides output during the period between receiving an activation request and receiving a stop request. Latch: Provides 1 second of output upon receiving an activation request and 1 second of output upon receiving a stop request.
3-27 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) 6.7. Serial Bridge Setting Step 1. Click on the [Serial] tab of the System Setting Tool. Step 2. Tick [Enable serial port]. The setting screen will be displayed, allowing entry of each item. NX-100 only Step 3.
3-28 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) (3) Baud rate Select [9600], [19200], [38400], [57600] or [115200] (4) Data length Set to either [7 bits] or [8 bits]. (5) Parity Select [Even], [Odd] or [None]. (6) Stop bits Select [1 bit] or [2 bits].
3-29 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) 6.8. System Settings Step 1. Click on the [System] tab of the System Setting Tool. The setting screen will be displayed. Step 2. Perform settings for each item. (1) Unit Enter the unit name. (2) Audio input Enter the name of the audio input unit connected to the unit.
3-30 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) 6.10. Reopening Unit Setting Files Reopen the saved unit setting files. The program automatically reads the saved unit setting files at the time of program activation. Whenever a file has not yet been saved after edit completion, its contents can be reverted back to the previous settings.
3-31 Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM) 7. CHANGING THE SYSTEM NAME AND P ASSWORD Step 1. In the Installation Setting Program, click on [Password Change] on the initial screen. In the Management Setting Program, select [Help] → [Version data], and a dialog will then be displayed.
Chapter 4 SYSTEM SETTINGS (SETTING USING BROWSER).
4-2 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) 1. OUTLINE OF SETTING USING BROWSER Settings can also be changed without requiring installation of the dedicated NX-100 software by individually connecting to each NX-100/100S using the browser*.
4-3 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) Step 2. Enter a user name and password, then press the OK button. Notes • For the User name, enter the system name preset as default or by change. • Both the user name and password are case-sensitive.
4-4 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) 3. NETWORK SETTING Set the NX-100/100S unit's network. This figure represents the NX-100. (1) IP Address Enter the NX-100/100S unit's IP address. (Factory-preset to "192.168.1.1.") (2) Subnet Mask Set the mask address.
4-5 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) (4) Port No. Set the start port number to be used by each protocol. The assigned port numbers are indicated. [TCP Port No. Assignment] • Web server Enter the web server port number (Range: 1 – 65535; Factory-preset: 80) • Start port no.
4-6 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) 4. BROADCAST SPEC SETTING Set the specifications that determine broadcast streaming quality. The NX-100/100S starts its broadcasts based on this setting. This figure represents the NX-100. (1) Navigator Select the usable bandwidth and type of line, and press the Set button.
4-7 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) (2) Information Indicates the delay time, bandwidth, and whether or not broadcasts are possible when broadcasts are made using values selected in the Broadcast Spec settings.
4-8 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) (4) Network Relations [Packet Size] Select the size of audio packet. The packet size cannot be changed when [Resend] is selected in Packet Loss Recovery item. Smaller packet sizes result in a wider bandwidth, however delay times become shorter.
4-9 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) 5. BROADCAST P A TTERN SETTING The broadcast pattern is determined by the combination of broadcast direction and the units targeted to receive or transmit the broadcast, and is set in the unit that initiates the broadcast.
4-10 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) 5.1. Pattern Selection Area (1) Programmed Pattern List Displays a list of the unit's programmed patterns, and whether or not broadcasts are possible.
4-11 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) (3) Target Unit The IP addresses of the target NX-100 and NX-100S units are displayed. When "Transmission" is selected in the Direction setting, broadcasts are sent all added NX-100 and NX-100S target units.
4-12 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) 5.2.2. Pattern editing When the Pattern Edit button is pressed while a programmed broadcast pattern is selected in the pattern selection area, the Edit of Pattern title and the name of the pattern before being changed are displayed.
4-13 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) 6. CONT ACT SETTING When the NX-100/100S unit's contact input is activated, its set broadcast pattern starts broadcasting while simultaneously enabling other unit's contact outputs. Here, contact input and output settings are performed.
4-14 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) 6.1. Contact Input Setting Set the broadcast pattern to be started, and the contact bridge. When the contact input is selected, the screen will switch over to the contact input setting screen. Select [Enable] and set the contact input contents.
4-15 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) (3) Broadcast Pattern The NX-100/100S unit's list of programmed broadcast patterns is displayed.
4-16 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) 6.2. Contact Output Setting Set the contact output to be activated when the NX-100/100S is enabled by other unit or the operation program. Selecting a contact output will switch the display to the contact output setting screen.
4-17 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) (2) Type Select from [Momentary] and [Latch]. Momentary: Provides output during the period between receiving an activation request and receiving a stop request. Latch: Provides 1 second of output upon receiving an activation request and 1 second of output upon receiving a stop request.
4-18 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) 7. SERIAL BRIDGE SETTING NX-100 only Perform serial bridge settings. (1) Enable/Disable Selection Select "Enable" when using this function. All items can be ready for entry. (2) Network Setting [Protocol] Select the serial bridge communication configuration.
4-19 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) (3) Serial Port Setting [Baud Rate] Select [9600], [19200], [38400], [57600], or [115200] [Data Length (bit)] Select to [7 bits] or [8 bits]. [Parity] Select [Even], [Odd], or [None]. [Stop Bit] Select [1 bit] or [2 bits].
4-20 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) 8. LOG MANAGEMENT The unit's operation logs are displayed and saved. This figure represents the NX-100. (1) Operation Log button Displays the NX-100/100S unit's operation log. (2) Stream Log button Displays streaming reception log.
4-21 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) 8.1. Operation Log The operation log screen is displayed when the Operation Log button is pressed on the Log Management Menu screen. This figure represents the NX-100. [Operation button] (1) Latest button Updates the operation log to current data.
4-22 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) [Items in the Table] (1) Time Indicates the time the event took place. (2) Category Indicates the type of log.
4-23 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) 8.2. Saving Operation Logs Follow the procedures below to save logs to a PC: Step 1. Press the Operation Log Save button on the Log Management Menu screen. A dialog is displayed. Step 2. Press the Save Button.
4-24 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) 8.3. Stream Logs The Stream Log screen is displayed when the Stream Log button is pressed on the Log Management Menu screen. This figure represents the NX-100. [Operation Button] (1) Refresh button Updates to the most recent data.
4-25 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) [Items in the Table] (1) Current Stream • Stream Data • Reception Log Correct Reception: The number of packets received correctly. (The number of error packets or recovered packets is not included.
4-26 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) 8.4. Operation Status The Operation Status screen is displayed when the Operation Status button is pressed on the Log Management Menu screen. This figure represents the NX-100. [Operation Button] (1) Refresh button Updates status to the most recent data.
4-27 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) 9. SYSTEM MANAGEMENT Note The System Management Utility area is not displayed when in Management Setting mode. [Unit Data] (1) Unit Name Enter the NX-100/100S unit's name. (2) Audio Input Unit Name Enter a name when connecting the audio input unit.
4-28 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) (4) Unit Data Change button Updates only system setting data in the NX-100/100S setting file. Caution Never restart the unit or turn off the power during updates, or while the STATUS indicator on the front panel of the NX-100/100S is flashing.
4-29 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) [System Management Utility] (1) Setting File Upload Uploads backed up setting files. Step 1. Press the Browse button. The Choose file dialog opens. Step 2. Select the backup file (.cfg extension), then press the Upload button.
4-30 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) (2) Setting File Download Backs up the setting file. Step 1. Press the Download button. A dialog is displayed. Step 2. Press the Save button. A dialog is displayed. Step 3. Select the save destination and enter a filename.
4-31 Chapter 4: SYSTEM SETTINGS (SETTING USING BROWSER) (3) Delete All Settings Deletes all settings to return them to their original settings when supplied. The unit is factory-preset as follows: IP Address: 192.168.1.1 Unit Name: NX-100S System Name: NX-100 Password: guest Other settings can be viewed with a browser or the setup program.
Chapter 5 OPERA TION SETTINGS (NX-100 OPERA TION PROGRAM).
5-2 Chapter 5: OPERATION SETTINGS (NX-100 OPERATION PROGRAM) 1. NX-100 OPERA TION PROGRAM SUMMAR Y This operation program is used to set the control buttons used for broadcasts, and activate set NX-100 and NX-100S broadcast patterns* 1 or operate the contact output* 2 .
5-3 Chapter 5: OPERATION SETTINGS (NX-100 OPERATION PROGRAM) 3. OPERA TION SCREEN DESCRIPTION This section explains the screen layout, using the accompanying operation setting screen as an example. (2) (5) (1) (3) (4) (1) Selection Button Selects the broadcast pattern and contact output to be activated.
5-4 Chapter 5: OPERATION SETTINGS (NX-100 OPERATION PROGRAM) 4. MENU 4.1. File Exit: Terminates the software program currently in use. 4.2. Settings Button setting: Set the Selection button and the Group button.
Before performing the setting using the Operation program Set the NX-100 and NX-100S units in the system using the NX-100 Setup program. Broadcast settings that will be activated by the operation program must all be programmed into each connected unit as the "broadcast pattern.
5-6 Chapter 5: OPERATION SETTINGS (NX-100 OPERATION PROGRAM) 6. UNIT SETTING ADDITION Set the broadcast pattern data necessary for the Selection button setting using the NX-100 Setup program (refer to Chapter 3 ). If a unit setting file has already been created, the data is automatically loaded.
5-7 Chapter 5: OPERATION SETTINGS (NX-100 OPERATION PROGRAM) Step 4. Press the Add button. A Unit Addition dialog is displayed. Step 5. Enter the IP address and port number (Web server, TCP start port number, and UDP start port number), then press the OK button.
5-8 Chapter 5: OPERATION SETTINGS (NX-100 OPERATION PROGRAM) 7. EDITTING THE BUTT ON LA YOUT The Start button can be set to enable or disable, and the layout of the Selection and Group buttons can be edited. Step 1. Start the Operation program and select [Setting] → [Button setting].
5-9 Chapter 5: OPERATION SETTINGS (NX-100 OPERATION PROGRAM) Step 3. Click on the Button layout tab, then perform settings for each item shown on the screen. In the initial startup mode, the following screen is displayed. (1) (2) (3) (1) Enable start button When the box is unchecked, the Start button on the operation screen is disabled and hidden.
5-10 Chapter 5: OPERATION SETTINGS (NX-100 OPERATION PROGRAM) (1) (2) (3) [Registration Contents List] (1) Visible Displays or hides the Selection buttons. (2) No. Selection button numbers. These numbers cannot be changed. The buttons are arranged in the order of the button number (see figure at right) on the operation screen.
5-11 Chapter 5: OPERATION SETTINGS (NX-100 OPERATION PROGRAM) Step 2. Click off the checkbox ticks in the Registration Contents List for Selection buttons not to be used on the operation screen. Buttons not marked with a tick are not displayed on the operation screen.
5-12 Chapter 5: OPERATION SETTINGS (NX-100 OPERATION PROGRAM) Step 7. Check the contact channel number to be used. Tip To clear the setting contents of all NX-100 and NX-100S contact outputs, press the leftmost Clear button in the Edit area. Step 8. Press the OK button after completing all editing tasks.
5-13 Chapter 5: OPERATION SETTINGS (NX-100 OPERATION PROGRAM) 9. SETTING THE GROUP BUTT ON CONTENTS The Group button is used to simultaneously select two or more Selection buttons. Program the desired Selection buttons into the Group button. Step 1. Click on the Group button tab on the Button Setting screen ( p.
5-14 Chapter 5: OPERATION SETTINGS (NX-100 OPERATION PROGRAM) Step 3. Click on the Group buttons (the No. or Indication Name area) to be edited in the Registration Contents List. The contents are displayed in the Edit area. Step 4. Enter the Indication name in the Edit area.
5-15 Chapter 5: OPERATION SETTINGS (NX-100 OPERATION PROGRAM) Points to Check The NX-100 or NX-100S unit may have failed. Check to see if the power supply is correctly connected, that there are no irregularities in the network, and whether or not the NX-100's or NX-100S' front panel-mounted Error indicator is lit.
Chapter 6 APPENDIX.
6-2 Chapter 6: APPENDIX 1. EXPLANA TION 1.1. IP Network and Address The IP networks the NX-100 and NX-100S can use include Local Area Networks (LAN) used in small-scale areas, such as within or on the premises of a company, and the Internet, which covers a wide area over remote distances.
6-3 Chapter 6: APPENDIX 1.2. Network Address T ranslation (NA T) and Setup Software Programs Because the Internet cannot be accessed using the local IP address, the local IP address must be converted into the global IP address by means of Network Address Translation (NAT).
6-4 Chapter 6: APPENDIX 1.4. Multicast and Simultaneous Multiple Broadcasts The multicast communication method can be utilized to make simultaneous broadcasts to two or more units. The advantage of multicast operation is the possibility of decreasing traffic.
6-5 Chapter 6: APPENDIX 2. INDICA T OR ST A TUS AND TROUBLESHOOTING 00-05-F9-FF-80-81 NETWORK AUDIO ADAPTER NX-100S LNK/ACT FD/COL SIGNAL INPUT PEAK STATUS ERROR RUN RESET 1 2 3 4 5 6 7 This figure represents the NX-100S. Indicator status: Lighting, Flashing, Off 1.
6-6 Chapter 6: APPENDIX [Error indicator status] Possible cause and remedy Power off AC adapter is disconnected. → Ensure the connection of power supply. CPU error (CPU hang-up) → Contact your TOA dealer. Data write error Writing data failed because the unit's power is shut off or other trouble occurs during data write or firmware update.
6-7 Chapter 6: APPENDIX Remedy Confirm that power is correctly connected. Turn power on again. Confirm that LAN cable is correctly connected. Confirm that the NX-100/100S is connected to the correct switching hub's port and that the proper type of cable is used for the connection.
6-8 Chapter 6: APPENDIX Remedy Confirm that sound source equipment, amplifier, and speaker are correctly connected. Confirm that audio input volume control is properly adjusted. Confirm that the rear-mounted input level selection switch is set to appropriate position.
6-9 Chapter 6: APPENDIX 4. SPECIFICA TIONS 4.1. NX-100 * 0 dB = 1 V Note: The design and specifications are subject to change without notice for improvement.
6-10 Chapter 6: APPENDIX * 0 dB = 1 V Note: The design and specifications are subject to change without notice for improvement. • Optional products Rack mounting bracket: MB-15B-BK (for rack-mountin.
200708 URL: http://www.toa.jp/.
デバイスTOA Electronics NX-100の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
TOA Electronics NX-100をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはTOA Electronics NX-100の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。TOA Electronics NX-100の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。TOA Electronics NX-100で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
TOA Electronics NX-100を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はTOA Electronics NX-100の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、TOA Electronics NX-100に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちTOA Electronics NX-100デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。