i Single Station Wa ter proof Timer Installation and Programming Guide Single Station Wa ter proof Timer Installation and Programming Guide Features • Up to four irrigation cycles per day • Easy installation and programming • Battery powered • Waterproof and weather resistant 7 1 2 3 4 5 6 S S M T W T F 1234 AM PM 24 Part No.
ii ii Table of Contents P arts Identication ................................................................................................................ 1 Battery Installation ....................................................................
1 1 1 2 2 3 3 5 5 4 4 Parts Identification Congratulations on purchasing a T oro ® S ingle Station Timer (SST). Y ou have a po werful but easy to use battery-operated valve controller that ts most common valves*. e SST comes with a DC-Latching solenoid attached, making connecting to your valve simple and easy .
2 Battery Installation Battery installation should take place before attaching the SST to a valve. If you hav e already attached the SST to a valve, you will need to detach it. 1. Place the SST face down. e battery compartment is sealed with four (4) screws.
3 * e included DC-latching solenoid is not compatible with Hunter® brand valv es. Use of the SST with Hunter valv es requires a H unter DC-latching solenoid (sold separately). Hunter is a trademark of H unter Industries. Attaching the SST to a Valve e SST includes a pre-wired DC-latching solenoid*.
4 LCD Overview 1. Low battery indicator . If the icon is ashing, the battery is low and should be changed. If the icon is solid, the controller will not operate. Replace the battery . 2. Set current time indicator 3. Digital display . Shows the curr ent time or run-time during programming.
5 Programming the SST Ev er y programming operation begins by pr essing the MODE button. A long press (>2 seconds) turns the controller o. A short press (<2 seconds) advances the controller through the dierent pr ogramming functions in the order that follows.
6 Set Clock 1. e icon shows. e hour number ( 12:00 or 00:00 depending on mode chosen above) will ash. P ress or to cycle to the correct hour . If in AM/PM mode, AM or PM will be set in Step 5. 2. Pr ess to enter selection. 3. e minute number ( 00:00 ) will ash.
7 Set Run Time 1. e icon shows. e default run time per program is 10 minutes. 2. Pr ess or to adjust the hours. Pr ess . 3. Pr ess or to adjust the minutes. 4. Pr ess once to set and advance to the next programming option. Set Start Time is setting has 4 possible start times to allow watering up to four times a day .
8 Pr ess or to cycle to the correct start time hour . Press to set. 4. e minute number ( 00:00 ) will ash. P ress or to advance to the correct start time minute.
9 day , irrigation will run past midnight. Off Mode OFF mode turns o the watering program. Active Day bo xes disappear . e time display and “OFF” toggle back and forth on the display . e current day ashes. 1. Pr ess for >2 seconds to activate OFF mode.
10 Manual Operation 1. T o turn on the valve manually , press and together . 2. e valve will run for the programmed run-time (page 8). 3. T o prematurely ST OP a manual operation, press and together . Stopping the Current Irrigation Cycle It is possible to stop the curr ent irrigation cycle.
11 Installing a Rain Sensor It is possible to connect a wir ed T oro® RainS ensor™ to the SST . Other normally closed sensors can be installed as well. Wir ed polarity is not observed for the sensor . 1. Cut the wire loop (y ellow) from the SST . (See F igure 1.
12 The Reset Button e Reset button resets the controller to erase all watering programs. 1. Remov e the batter y compartment lid and battery . 2. In the upper left corner , you will see a black button with a refresh symbol. U sing a screwdriver , press that button.
13 Troubleshooting Guide Pr oblem P ossible Cause Solution Controller does not display anything. 1. e battery is dead. 2. Controller is in Sleep mode. 1. Install a new 9V battery . 2. Press MODE to activate scr een. W ater does not turn ON. 1. Faulty contr ol valve wire connections.
14 The T oro Company and its afliate, T oro W arranty Company, pursuant to an agreement between them, jointly warrants, to the owner , against defects in material and workmanship for a period of two years from the date of purchase.
デバイスToro 53887の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Toro 53887をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはToro 53887の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Toro 53887の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Toro 53887で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Toro 53887を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はToro 53887の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Toro 53887に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちToro 53887デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。