ToroメーカーFLX55の使用説明書/サービス説明書
ページ先へ移動 of 12
Introduction The FLX35 and FLX55 series full and part circle rotary sprinklers are designed specifically for golf course applications. Manufactured from durable, high-strength engineering plastic and stainless-steel components, these sprinklers incorporate many innovative and time-proven features for lasting, maintenance-free operation.
Nozzle Performance Chart FLX35 Series Performance Chart—25° Front Nozzle Positions Nozzle Set 30 (White Plug) Nozzle Set 31 (Yellow) Nozzle Set 32 (Blue) Nozzle Set 33 (Brown) Nozzle Set 34 (Orange.
Precipitation Rate Formulas • Square-spaced sprinklers in pattern: GPM of full circle x 96.3 (Spacing) 2 • Triangular-spaced sprinklers in pattern: GPM of full circle x 96.3 (Spacing) 2 (0.866) • Area and flow: Total GPM of zone x 96.3 Total irrigated Square feet of zone • Single row: GPM of full circle x 96.
Connecting Hydraulic Control Tubing Step 1 – Route control tubing from the controller to the sprinkler location(s). Note: Leave an 18" (45.7 cm) service loop of tubing at each sprinkler to facilitate movement of sprinkler and service operations.
Winterization Winterizing the irrigation system is required in freezing climates to prevent damage from water expansion when it freezes. Following are three key points for successfully winterizing the.
Adjustment Band Indicators 90° 180° 270° 360° Figure 7 For reference, the adjustment band of the FLX35 and FLX55 has markers at predetermined arcs. By aligning the adjustment band indicators to the turret arrow, you can set the sprinkler arc to 90°, 180°, 270° or 360°.
Pilot Valve Operation (Electric Models Only) The pilot valve controls the operation of the main valve located in the 100 PSI (7.0 kg/cm 2 ) 80 PSI (5.6 kg/cm 2 ) 65 PSI (4.
Valve won’t close (Hydraulic) – Leak in control tubing • Isolate and repair – Pilot valve leak in controller • Confirm by observing constant dripping from discharge line of controller.
Servicing Sprinkler Mechanism WARNING! Never stand or lean over the sprinkler while the irrigation system is being filled, during manual or automatic operation or when performing sprinkler service procedures.
Servicing Main Valve WARNING! If the valve snap ring is difficult to remove, residual water pressure may be remaining in the system. To prevent possible serious injury due to valve being ejected upward under pressure, confirm the following conditions exist prior to removing the snap ring and valve.
Servicing Pilot Valve WARNING! Never stand or lean over the sprinkler while the irrigation system is being filled, during manual or automatic operation or when performing sprinkler service procedures.
NOTES: © 2015 • The Toro Company, Irrigation Division • www.toro.com Form Number 373-0859 Rev. A.
デバイスToro FLX55の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Toro FLX55をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはToro FLX55の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Toro FLX55の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Toro FLX55で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Toro FLX55を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はToro FLX55の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Toro FLX55に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちToro FLX55デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。