BeckettメーカーADCの使用説明書/サービス説明書
ページ先へ移動 of 16
Potential for Fire, Smoke and Asphyxiation Hazards T o the Homeowner or Equipment Owner: y Please read and carefully follow all instructions provided in this manual regarding your responsibilities in caring for your heating equipment. y Contact a professional, quali fi ed service agency for installation, start-up or service work.
2 Contents Burner Application Scope and Intended Use ........... 2 Prepare Before Installing ............................................ 3 Speci fi cations ..................................................................... 3 Notice Special Requirements.
3 12 Vdc ADC Burner Manual Section: Prepare Before Installing Owner ’ s Responsibility Incorrect installation, adjustment, and use of this burner could result in severe personal injury , death, or substantial property damage from fi re, carbon monoxide poisoning, soot or explosion.
4 Figure 1. T ypical Burner Nameplate T able 1. Low Firing Rate Baf fl e Head T ype Low Firing Rate Baf fl e (if speci fi ed) F0 up to 0.65 gph F3 up to 0.85 gph F4 or F6 up to 0.90 gph T able 2. Air Tube Combination (A TC) Codes Firing Rate GPH Head Static Plate Size A TC Codes for Usable Air T ube Lengths: (‘A ’ in inches see Fig.
5 12 Vdc ADC Burner Manual 10 11 6 8 1 2 7 4 9 3 5 4 90 ° Contacts to be parallel with horizontal center line within 2°. Electrode gap to be centered with nozzle center .
6 Figure 4. ‘Z’ Dimensions Using Gauge SK9787 Section: Nozzle Assembly Maintenance B. Check/Adjust Electrodes Check the electrode tip settings. Adjust if necessary to comply with the dimensions shown in Figure 2 . T o adjust, loosen the electrode clamp screw and slide/rotate electrodes as necessary .
7 12 Vdc ADC Burner Manual For oil supply system speci fi cations for tanks not mounted on machines, carefully follow the pump manufacturer ’s literature and the latest edition of the National Fire Protection Association (NFP A) 31 standard. Pumps with automatic bypass do not require a bypass plug.
8 Section: Burner Wiring Figure 6A. T ypical Wiring For Constant Duty Ignition - With No Primary Control Figure 6B. T ypical Wiring For Interrupted Ignition - With No Primary Control 30A FUSE IGNITER .
9 12 Vdc ADC Burner Manual Figure 6C. T ypical Wiring with 7556 Primary Safety Control Section: Drive Component Maintenance Driv e Component Maintenance A.
10 Section: Drive Component Maintenance B. Pump Maintenance General Pump Information Important information - Long or oversized inlet lines may require the pump to operate dry during initial bleeding period. In such cases, the priming may be assisted by injecting fuel oil in the pump gear set.
11 12 Vdc ADC Burner Manual Section: Start Up Burner & Set Combustion Explosion and Fire Hazard Failure to follow these instructions could lead to equipment malfunction and result in heavy smoke emission, soot-up, hot gas puff-back, fi re and asphyxiation hazards.
12 Section: Maintain & Service Burner Professional Service Required Incorrect installation, adjustment, and use of this burner could result in severe personal injury , death, or substantial property damage from fi re, carbon monoxide poisoning, soot or explosion.
13 12 Vdc ADC Burner Manual T roubleshooting Oil burners that are designed for use on road maintenance equipment are built to take temperature extremes, vibration, and rough handling.
14 Section: T roubleshooting T able 4. Troubleshooting Chart Symptom Possible Cause Oil Not Igniting If the burner is not igniting, the burner motor , drive coupling, and oil pump are operating and oil is fl owing to the nozzle through the solenoid valve, check the following possibilities.
15 12 Vdc ADC Burner Manual 1 2 3 4 5 6 7 8 9 12 10 11 13 14 15 16 18 19 17 21 20 22 23 R eplacement P ar ts Illustration # Description Part# 1 DC Motor n/a 2 Blower Wheel 2999U 3 Coupling 2140501 4 A.
The R. W . BECKETT CORPORA TION (“Beckett”) warrants to persons who purchase its “Products” from Beckett for resale, or for incorporation into a product for resale (“Customers”), that its equipment is free from defects in material and workmanship.
デバイスBeckett ADCの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Beckett ADCをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBeckett ADCの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Beckett ADCの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Beckett ADCで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Beckett ADCを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBeckett ADCの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Beckett ADCに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBeckett ADCデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。