RWB 6104 BAFII R01 Page 1 Model AFII Oil Burner Potential for Fire, Smoke and Asphyxiation Hazards T o the Homeowner or Equipment Owner: Please read and carefully follow all instructions provided in this manual regarding your responsi- bilities in caring for your heating equipment.
Page 2 RWB 6104 BAFII R01.
RWB 6104 BAFII R01 Page 3 T able of Contents General Information Hazard De fi nitions ...................................................................................................................... .................. 4 Owner ’s Responsibility .
Page 4 RWB 6104 BAFII R01 General Infor ma tion General Information Within the boundaries of the hazard warning, there will be information presented describing consequences if the warning is not heeded and instructions on how to avoid the hazard.
RWB 6104 BAFII R01 Page 5 General Speci fi cation T able 1 – Burner Speci fi cations Capacity ‘HLX’ Heads Firing rate: - 0.40 – 1.50 GPH Input: Min./Max - 56,000 /210,000 Btu/h ‘FBX’ Heads Firing rate: - 0.40 – 1.35 GPH Input: Min./Max.
Page 6 RWB 6104 BAFII R01 Inspect/Prepar e Installation Site Inspect Chimney or Direct V ent System Inspect the chimney or vent. Make sure it is properly sized and in good working condition. Follow the in- structions supplied by the appliance manufacturer .
RWB 6104 BAFII R01 Page 7 Never use T e fl on tape on fuel oil fi ttings. T ape fragments can lodge in fuel line components and fuel unit, damaging the equipment and pre- venting proper operation. Use oil-resistant pipe sealant compounds. • • • Damage to the pump could cause impaired burn- er operation, oil leakage and appliance soot-up.
Page 8 RWB 6104 BAFII R01 The burner is supplied with either a one-stage pump or a two-stage pump based on the oil supply system requirements. Consult the instructions pro- vided with the pump for installation speci fi cations.
RWB 6104 BAFII R01 Page 9 Star t the Bur ner and Set Combustion Figure 4. – T ypical Wiring, R7184 Primary Control SK9359 7. RECYCLE. If the fl ame is lost while the burner is fi ring, the control shuts down the burner , enters a 60 second recycle delay , and then repeats the above ignition sequence.
Page 10 RWB 6104 BAFII R01 If the burner locks out on safety during bleed- ing, reset the safety switch and complete the bleeding procedure. Note — Electronic safety switches can be reset immediately; others may require a three- to fi ve-minute wait.
RWB 6104 BAFII R01 Page 1 1 If motor is not permanently lubricated, oil motor with a few drops of SAE 20 nondetergent oil at each oil hole. DO NOT over oil motor . Exces- sive oiling can cause motor failure. Check motor current. The amp draw should not exceed the nameplate rating by more than 10%.
Page 12 RWB 6104 BAFII R01 Inspect the nozzle adapter before installing the new nozzle. If it is grooved or scratched on the sealing surface, replace the nozzle line assem- bly . If the surface is damaged, oil could leak at the nozzle to adapter joint, causing serious com- bustion problems.
RWB 6104 BAFII R01 Page 13 Stop Screw AFII 85 AFII 100 AFII 150 0 0.40-0.65 0.5-0.65 0.75-1.00 1 - 0.6-0.75 0.85-1.10 2 - 0.65-0.80 0.95-1.15 3 0.60-0.75 0.65-0.90 0.95-1.20 4 - 0.75-0.95 1.10-1.25 5 0.70-0.85 0.85-1.00 1.15-1.35 6 - 0.95-1.10 1.15-1.
Page 14 RWB 6104 BAFII R01 For best performance specify genuine Beckett replacement parts R eplacement Par ts Diag r am Beckett 10 8 21 11 16 17 6 18 14 7 4 20 22 9 5 15 2 13 23 3 19 12 1 SK8265B.
RWB 6104 BAFII R01 Page 15 Item Description Kit No. 1 Air tube combination Specify 2 Blower Wheel: AFII 85 (4-1/4”) AFII 100 (4-1/2”) AFII 150 (4-1/2”) 21439U 21438U 21438U 3 Electrical box 3061.
Page 16 RWB 6104 BAFII R01 Limited WARRANTY For Residential, Commercial and Specialty Burners The R. W. BECKETT CORPORATION (“Beckett”) warrants to persons who purchase its Beckett burners from Be.
デバイスBeckett AFII 150の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Beckett AFII 150をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBeckett AFII 150の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Beckett AFII 150の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Beckett AFII 150で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Beckett AFII 150を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBeckett AFII 150の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Beckett AFII 150に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBeckett AFII 150デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。