BeckettメーカーCF 1400の使用説明書/サービス説明書
ページ先へ移動 of 16
14 0 0 Instruction M anual ON/OFF Operation Firing rate: 4.0 – 10.0 GPH Motor voltage: 120 / 60 Hz std. MODEL MODEL MODEL MODEL MODEL CF 1 400 Oil Burner Thank you for purchasing a Beckett burner . With proper care and regular maintenance, it will provide years of trouble-free service.
2 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Please . . . r ead this page first Hazard definitions The following will be used throughout this manual to bring attention to hazards and their risk factors, or to special informati on.
3 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Contents Please . . . read this page first ................ 2 Pre-installation checklist ........................... 4 Mount the burner .......................................... 6 Connect fuel line(s) .
4 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Pr e-installation checklist ❏ Combustion air supply • The burner requires combustion air and ventilation air for reliable operation. Assure that the building and/or com- bustion air openings comply with National Fire Protection Standard for Oil-Burning Equipment, NFP A 31.
5 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Figure 1 - Min. Combustion chamber dimensions 1405 A L Figure 2 - Air tube mounting dimensions E T D 2° 1404 G 1 E Insertion depth G Air tube to inside of chamber – 0.25" ± 0.
6 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Mount the bur ner ❏ Mount flange(s) on air tube • This section does not apply to burners with welded flanges. • Do not install air tube on burner . • For non-pressure firing flange , refer to Figure 3 : Install gasket (item a ) and flange (item d ).
7 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Figure 5 - Nozzle line assembly in burner Z 1408 a Measure dimension from front (flat) face of head to end of air tube, as sho wn. Z b c d Measure dimension Z from the flat surface between (not on) the raised f ins.
8 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Install the oil lines using the following guidelines. Failure to comply could lead to equipment damage and present a risk of severe personal injury , death or substantial property damage due to leakage of oil and potential fire hazard.
9 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Figure 9a – T wo-pipe oil flow with “H” pump 300 psig k g 1413ao d a b p 300 psig c Figure 9b – T wo-pipe oil flow with .
10 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Wir e the bur ner Install the burner and all wiring in accordance with the National Electrical Code and all applicable local codes or requirements. W ire the burner in compliance with all instructions provided by the appliance manufacturer .
11 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Sequence of operation — typical 1. On call for heat from the appliance operating controls (and the circuit from T to T of the R8184 closed), power is applied to the R8184 black wire ( BK ).
12 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Pr epar e the bur ner for star t-up - continued ❏ Z dimension • Should be set per these instructions (see page 7). The top acorn nut ( Figure 11 , item d ) should never be loosened once the Z dimension is initially set.
13 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Figure 12 – Air damper assembly T able 5 – Initial air adjusting plate settings (damper position) 12 0 1 2 3 4 5 6 7 8 9 10.
14 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner Star t the bur ner Do not proceed unless all prior steps in this manual have been completed. Failure to comply could result in se v ere personal injury , death or substantial property damage.
15 Form 6104 BCF14N-R0299 Instruction Manual – Model CF1400 Oil Burner ❏ Set air adjusting plate ( Figure 12 ) 1. Allow the burner to run until the appliance has warmed suff iciently . 2. V isually chec k the flame. The flame should not be dark orange or smoky .
U.S.A.: P . O. Box 1289 • Elyria, Ohio 44036 • 800-645-2876 • 440-327-1060 • F AX 440-327-1064 Canada: R. W . Beckett Canada, Ltd. • 430 Lair d Road • Guelph, Ontario, N1G 3X7 • 800-665-.
デバイスBeckett CF 1400の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Beckett CF 1400をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBeckett CF 1400の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Beckett CF 1400の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Beckett CF 1400で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Beckett CF 1400を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBeckett CF 1400の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Beckett CF 1400に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBeckett CF 1400デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。