2500/3500 MODEL MODEL MODEL MODEL MODEL CF CF 2500/ 3500 Instruction M anual Oil Burner Thank you for purchasing a Beckett burner . With proper care and regular maintenance, it will provide years of trouble-free service. Please take a few minutes to read the section entitled “T o the owner” inside this manual.
Instruction Manual – Model CF2500/CF3500 Oil Burner 2 Form 6104 BCF-35-R0699 Please . . . r ead this page first Denotes presence of a hazard which, if ignored, could result in minor personal injury or property damage.
Instruction Manual – Model CF2500/CF3500 Oil Burner 3 Form 6104 BCF-35-R0699 W arranty Beckett warrants its equipment to those who have purchased it for resale, including your dealer . If you have an y problems with your equipment or its installation, you should contact your dealer for assistance.
Instruction Manual – Model CF2500/CF3500 Oil Burner 4 Form 6104 BCF-35-R0699 Pr e-installation checklist T able 1 – Nozzle capacities at various pressures ❏ Combustion air supply • The burner requires combustion air and ventilation air for reliable operation.
Instruction Manual – Model CF2500/CF3500 Oil Burner 5 Form 6104 BCF-35-R0699 3502 E D G F T 2 ° 1 T able 2 – Air tube capacity vs. firebox pressure Figure 2 – Air tube mounting dimensions E Insertion depth G Air tube to inside of chamber – 0.
Instruction Manual – Model CF2500/CF3500 Oil Burner 6 Form 6104 BCF-35-R0699 Mount the bur ner ❏ Mount flange(s) on air tube • This section does not apply to burners with welded flanges. • Do not install air tube on burner . • For non-pressure firing flange , refer to Figure 3 : Install gasket (item a ) and flange (item d ).
Instruction Manual – Model CF2500/CF3500 Oil Burner 7 Form 6104 BCF-35-R0699 Z 3506 a Measure dimension from front (flat) face of head to end of air tube, as sho wn.
Instruction Manual – Model CF2500/CF3500 Oil Burner 8 Form 6104 BCF-35-R0699 Connect fuel line(s) ❏ Fuel unit by-pass plug The CF2500A, CF2500 and CF3500A burners are shipped without the by-pass plug installed. Y ou must install this plug on tw o- pipe systems.
Instruction Manual – Model CF2500/CF3500 Oil Burner 9 Form 6104 BCF-35-R0699 Figure 9a T wo-pipe oil flow , one nozzle, low fire, “ H ” pump • Install two high-quality shutoff valves in accessible loca- tions on the oil supply line. Locate one valve close to the tank.
Instruction Manual – Model CF2500/CF3500 Oil Burner 10 Form 6104 BCF-35-R0699 Wir e the bur ner Install the burner and all wiring in accordance with the National Electrical Code and all applicable local codes or requirements. W ire the burner in compliance with all instructions pro vided by the appliance manufacturer .
Instruction Manual – Model CF2500/CF3500 Oil Burner 11 Form 6104 BCF-35-R0699 Sequence of operation — typical 1. On call for heat from the appliance operating controls (and the circuit from T to T of the R8184 closed), power is applied to the R8184 black wire ( BK ).
Instruction Manual – Model CF2500/CF3500 Oil Burner 12 Form 6104 BCF-35-R0699 Pr epar e the bur ner for star t-up - continued ❏ Z dimension • Should be set per these instructions (see page 7). The top acorn nut ( Figure 11 , item d ) should never be loosened once the Z dimension is initially set.
Instruction Manual – Model CF2500/CF3500 Oil Burner 13 Form 6104 BCF-35-R0699 T able 5 – Initial air adjusting plate settings (damper position) Figure 12 – Air damper and damper motor assembly L.
Instruction Manual – Model CF2500/CF3500 Oil Burner 14 Form 6104 BCF-35-R0699 Star t the bur ner Do not proceed unless all prior steps in this manual have been completed. Failure to comply could result in sev ere personal injury , death or substantial property damage.
Instruction Manual – Model CF2500/CF3500 Oil Burner 15 Form 6104 BCF-35-R0699 Maintenance and ser vice Annual service — by qualified service technician Have the burner inspected, tested and started at least annually by a qualified service technician.
Instruction Manual – Model CF2500/CF3500 Oil Burner Form 6104 BCF-35-R0699 U.S.A.: P . O. Box 1289 • Elyria, Ohio 44036 • 800-645-2876 • 440-327-1060 • F AX 440-327-1064 Canada: R.
デバイスBeckett CF 2500/ 3500の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Beckett CF 2500/ 3500をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBeckett CF 2500/ 3500の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Beckett CF 2500/ 3500の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Beckett CF 2500/ 3500で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Beckett CF 2500/ 3500を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBeckett CF 2500/ 3500の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Beckett CF 2500/ 3500に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBeckett CF 2500/ 3500デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。