BeckettメーカーCF 500/800の使用説明書/サービス説明書
ページ先へ移動 of 16
500/800 Instruction M anual ON/OFF Operation Firing rate: CF500: 1.75 – 5.50 GPH CF800: 3.00 – 8.00 GPH Motor voltage: 120 / 60 Hz std. MODEL MODEL MODEL MODEL MODEL CF 500/ Oil Burner Thank you for purchasing a Beckett burner . With proper care and regular maintenance, it will provide years of trouble-free service.
2 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner Please . . . r ead this page first Hazard definitions The following will be used throughout this manual to bring attention to hazards and their risk factors, or to special information.
3 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner Contents Please . . . read this page first ................ 2 Pre-installation checklist ........................... 4 Mount the burner ........................................
4 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner Pr e-installation checklist ❏ Combustion air supply • The burner requires combustion air and ventilation air for reliable operation.
5 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner ❏ V erify firing rate • Refer to appliance manufacturer’ s instructions (if avail- able) for firing rate and nozzle selection.
6 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner Mount the bur ner ❏ Mount flange(s) on air tube • This section does not apply to burners with welded flanges. • Do not install air tube on burner . • For non-pressure firing flange , refer to Figure 3 : Install gasket (item a ) and flange (item d ).
7 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner Figure 5 - Nozzle line assembly in burner Legend c acorn nut d fastener e Indicator adjusting plate f Secondary adjusting plate Figure 6 - Adjusting plate assembly ❏ Install nozzle line assembly • Insert the nozzle line assembly into the burner air tube.
8 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner Connect fuel line(s) Install the oil lines using the following guidelines. Failure to comply could lead to equipment damage and present a risk of severe personal injury , death or substantial property damage due to leakage of oil and potential fire hazard.
9 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner T able 3 – Fuel unit gearset capacities ❏ Burner fuel flow • One-pipe systems – See Figure 7 for the fuel flow path. • Oil supply connects to one of the fuel unit inlet ports.
10 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner Figure 9a – T ypical wiring Wir e the bur ner — R7184 Install the burner and all wiring in accordance with the National Electrical Code and all applicable local codes or requirements.
11 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner Wir e the bur ner — R8184 (alter nate) Install the burner and all wiring in accordance with the National Electrical Code and all applicable local codes or requirements. W ire the burner in compliance with all instructions provided by the appliance manufacturer .
12 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner ❏ Z dimension • Should be set per these instructions (see page 7). The acorn nut ( Figure 6 , item c , page 7) should never be loosened once the Z dimension is initially set.
13 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner Star t the bur ner Do not proceed unless all prior steps in this manual have been completed. Failure to comply could result in se vere personal injury , death or substantial property damage.
14 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner Maintenance and ser vice The burner must be serviced at least annually by a qualified service technician to assure continued reliable operation. Operation and adjustment of the burner requires technical knowledge and the use of combustion test instruments.
15 Form 6104 BCF5-R0301 Instruction Manual – Model CF500/CF800 Oil Burner Replacement par ts Figure 10 – Adjustable mounting plates for CF500/CF800 Item Part name Description Part number 1 Air tub.
U.S.A.: P . O. Box 1289 • Elyria, Ohio 44036 • 800-645-2876 • 440-327-1060 • F AX 440-327-1064 Canada: R. W . Beckett Canada, Ltd. • 430 Lair d Road • Guelph, Ontario, N1G 3X7 • 800-665-.
デバイスBeckett CF 500/800の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Beckett CF 500/800をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBeckett CF 500/800の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Beckett CF 500/800の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Beckett CF 500/800で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Beckett CF 500/800を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBeckett CF 500/800の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Beckett CF 500/800に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBeckett CF 500/800デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。