BeckettメーカーCF375の使用説明書/サービス説明書
ページ先へ移動 of 16
6104 BCF3 R02 Page 1 Potential for Fire, Smoke and Asphyxiation Hazards T o the Homeowner or Equipment Owner : Please read and carefully follow all instructions provided in this manual regarding your responsibilities in caring for your heating equipment.
Page 2 6104 BCF3 R02 T able of Contents Before you begin .............................................................................................................................. ....... 2-4 T o the Owner .........................................
6104 BCF3 R02 Page 3 Bef or e y ou be gin . . . The following resources will give you addional information for your installation. W e suggest that you consult these resources whenever possible. Pay particular attention to the appliance manufacturer ’ s instructions.
Page 4 6104 BCF3 R02 Owner ’ s Responsibility: Follow These Instructions Exactly Contact a professional, quali fi ed service agency for the installation, adjustment and service of your oil burning system. Thereafter , have your equipment adjusted and inspected at least annually to ensure reliable operation.
6104 BCF3 R02 Page 5 Combustion air supply The burner requires combustion air and ventilation air for reliable operation. Assure that the building and/or com- bustion air openings comply with National Fire Protec- tion Standard for Oil-Burning Equipment, NFP A 31.
Page 6 6104 BCF3 R02 Figure 1. Min. Combustion Chamber Dimensions V erify fi ring rate Refer to appliance manufacturer ’ s instructions (if available) for fi ring rate and nozzle selection.
6104 BCF3 R02 Page 7 Mount the bur ner Mount fl ange(s) on air tube This section does not apply to burners with welded fl ang- es. Do not install air tube on burner . For non-pressur e fi ring fl ange , refer to Figure 3 : Install gasket (item a ) and fl ange (item d ).
Page 8 6104 BCF3 R02 Set dimension Z Loosen fastener c in Figure 6 . Slide the nozzle line and plate assembly until dimension Z in Figure 5 is 1-1/2” ±1/16” . When dimension Z (from end of air tube to fl at area of front face of head) is correctly set, tighten acorn nut c .
6104 BCF3 R02 Page 9 Install two high-quality shut-off valves in accessible locations on the oil supply line. Locate one valve close to the tank. Locate the other valve close to the burner , upstream of the fuel fi lter . Bur ner fuel fl ow One-pipe systems – See Figure 7 for the fuel fl ow path.
Page 10 6104 BCF3 R02 Keep Service Access Covers Securely Installed These covers must be securely in place to prevent electrical shock, damage from exter- nal elements, and protect against injury from moving parts. All covers or service access plates must be in place at all times except during maintenance and service.
6104 BCF3 R02 Page 1 1 Star t-up chec klist Combustion air supply and venting have been inspected and veri fi ed to be free of obstructions and installed in ac- cordance with all applicable codes. Oil nozzle has been selected correctly and securely in- stalled in the nozzle adapter .
Page 12 6104 BCF3 R02 Star t the Bur ner Do not attempt to start the burner when excess oil has accumulated in the appliance, the appliance is full of vapor , or when the combustion chamber is very hot. Do not attempt to re-establish fl ame with the burner running if the fl ame becomes extinguished during start- up, venting, or adjustment.
6104 BCF3 R02 Page 13 High Ef fi ciency/Positive Pr essure Appliances ; also vary from traditional appliances (see manufacturer ’ s recommendations). Follow these four steps to properly adjust the burner: Step 1: Adjust the air shutter/band until a trace of smoke is achieved.
Page 14 6104 BCF3 R02 Check motor current. The amp draw should not exceed the nameplate. Check all wiring for secure connections or insulation breaks. Check the pump pressure and cutoff function. Check primary control safety lockout timing. Check ignition system for proper operation.
6104 BCF3 R02 Page 15 R eplacement par ts Item Part Name/Description Part Number 1 Air T ube Specify 2 Flange Kit Specify 3 Electrode Assembly Specify 4 Air Shutter 3709 5 Nozzle Line Assembly Specify.
Page 16 6104 BCF3 R02 Limited WARRANTY For Residential, Commercial and Specialty Burners The R. W. BECKETT CORPORATION (“Beckett”) warrants to persons who purchase its Beckett burners from Beckett.
デバイスBeckett CF375の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Beckett CF375をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBeckett CF375の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Beckett CF375の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Beckett CF375で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Beckett CF375を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBeckett CF375の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Beckett CF375に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBeckett CF375デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。