COMMERCIAL PRODUCT S Models: CG10(A) • CG15 • CG25 • CG50 C O M M E R C I A L C OMMERCIAL G A S B U R N E R S G AS B URNERS OEM Setup Guide Speci fi cations for commercial and industrial gas- fi red heating appliances.
Commercial Gas Burner OEM Setup Guid e Boiler Burner Firing Mode Rate MBH Manifold Press ure in. w ater Damper Setting Blue / Red Head Type / Head Setting Shutter Band Settings Air Tube Insertio n Inches Armstrong LG-14 280 L P CG10 On/Off 282 1.9 10.
Commercial Gas Burner OEM Setup Guid e Boiler Burner Firing Mode Rate MBH Manifold Press ure in. w ater Damper Setting Blue / Red Head Type / Head Setting Shutter Band Settings Air Tube Insertio n Inches Buderu s G315 5 CG10 Low Fire Start 437 1.0 / 1.
Commercial Gas Burner OEM Setup Guid e Boiler Burner Firing Mode Rate MBH Manifold Press ure in. w ater Damper Setting Blue / Red Head Type / Head Setting Shutter Band Settings Air Tube Insertio n Inches Burnham MPC MPC 4 CG10 Low Fire Start 500 1.0 / 1.
Commercial Gas Burner OEM Setup Guid e Boiler Burner Firing Mode Rate MBH Manifold Press ure in. w ater Damper Setting Blue / Red Head Type / Head Setting Shutter Band Settings Air Tube Insertio n Inches Burnham V9A V903 A CG10 Low Fire Start 442 1.1 / 2.
Commercial Gas Burner OEM Setup Guid e Boiler Burner Firing Mode Rate MBH Manifold Press ure in. w ater Damper Setting Blue / Red Head Type / Head Setting Shutter Band Settings Air Tube Insertio n Inches H. B. Smith 19A 19A - 3 CG10 Low Fire Start 369 0.
Commercial Gas Burner OEM Setup Guid e Boiler Burner Firing Mode Rate MBH Manifold Press ure in. w ater Damper Setting Blue / Red Head Type / Head Setting Shutter Band Settings Air Tube Insertio n Inches H. B. Smith HE28 HE28- 4 CG15 Mod 580 / 11 46 1.
Commercial Gas Burner OEM Setup Guid e Boiler Burner Firing Mode Rate MBH Manifold Press ure in. w ater Damper Setting Blue / Red Head Type / Head Setting Shutter Band Settings Air Tube Insertio n Inches Peerless LC/LCE LC04 CG10 Low Fire Start 691 1.
Commercial Gas Burner OEM Setup Guid e Boiler Burner Firing Mode Rate MBH Manifold Press ure in. w ater Damper Setting Blue / Red Head Type / Head Setting Shutter Band Settings Air Tube Insertio n Inches Peerless TC TC-04 CG15 Mod 581 / 11 56 1.05 / 4.
Commercial Gas Burner OEM Setup Guid e Boiler Burner Firing Mode Rate MBH Manifold Press ure in. w ater Damper Setting Blue / Red Head Type / Head Setting Shutter Band Settings Air Tube Insertio n Inches Weil McLain 80 380 CG10 Low Fire Start 336 0.7 / 1.
Commercial Gas Burner OEM Setup Guid e Boiler Burner Firing Mode Rate MBH Manifold Press ure in. w ater Damper Setting Blue / Red Head Type / Head Setting Shutter Band Settings Air Tube Insertio n Inches Weil McLain 88 Series 2 488 CG10 Low Fire S tart 98 6 1.
COMMERCIAL PRODUCT S R.W . Beckett Corporation ● P .O. Box 1289, Elyria, Ohio 44036-1289 ● 1-800-645-2876 ● Fax: 888-327-481 1 R.W . Beckett Canada, Ltd. ● 430 Laird Road, Unit 3, Guelph, Ontario N1G 3X7 ● 1-800-665-6972 ● Fax: (519)763-5656 www .
デバイスBeckett CG10(A)の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Beckett CG10(A)をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBeckett CG10(A)の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Beckett CG10(A)の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Beckett CG10(A)で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Beckett CG10(A)を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBeckett CG10(A)の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Beckett CG10(A)に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBeckett CG10(A)デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。