Toshibaメーカーik-tf7uの使用説明書/サービス説明書
ページ先へ移動 of 36
For Customer Use Enter below the Serial # which is located on the bottom of the cabinet. Retain this information f or future ref erence. Model #: IK-TF7U Serial #: CAMERA CONTR OL UNIT IK-TF7U INSTR U.
2 SAFETY PRECA UTIONS Safety icons This manual contains saf ety instr uctions that must be observed in order to av oid potential hazards that could result in personal injuries, damage to y our equipment, or loss of data.
3 Note the follo wing instructions when installing. • Do not cov er the product with any material. • Do not place the product on any confined Inflammab le material such as a carpet or blanket. • Do not place the product in a narrow space, as this ma y cause heat to buildup inside the product.
4 1. CAUTIONS ON USE AND INST ALLA TION ..... 5 2. COMPONENTS ................................................ 5 3. NAMES AND FUNCTIONS .............................. 6 4. CONNECTION .................................................. 7 4. 1 Standard Connection .
5 1. CA UTIONS ON USE AND INST ALLA TION • Handling the unit. Do not drop , jolt, or vibrate, as this ma y result in damage to the unit. This ma y cause problems. T reat the camera cables carefully to pre vent cable problems, such as breaks in the cab le and loose connections.
6 3. NAMES AND FUNCTIONS 1 Camera cable f or ‘IK-TF7H’ terminal Where the camera cab le for ‘IK-TF7H’ is connected. 2 DISP button T o change the display mode. 3 PA GE b utton T o switch and select menus . 4 MENU UP button T o select the function to be confir med or changed on the menu.
7 4. CONNECTION 4. 1 Standard Connection DC IN 12V Connector used: HR10A-7R-4PB (HIROSE electronics Co. Ltd) or equivalent. DIGITAL Function I/O 1 +12V 13 2 +12V 2 3 GND 3 4 GND 4 5 6 7 8 9 10 11 12 1.
8 5. OPERA TION A camera head “IK-TF7H” is supposed to be connected to this camera control unit from this section. 1 Refer to the item " 4. CONNECTION", connect each equipment correctly . 2 Tu rn on the connected equipment and the power source of the camer a.
9 Meaning Au tomatic white balance adjustment finished correctly . A utomatic white balance adjustment cannot be perf or med because the video lev el is too low . Obtain the proper video lev el. A utomatic white balance adjustment cannot be perf or med because the video lev el is too high.
10 5. 3 G ain When the image is dark even if the lens iris is open, change the gain (video gain) to get the proper video le vel. F or the gain adjustment of the unit, MANU (Manual) and OFF (0 dB) modes are pro vided. Select the mode on the GAIN menu. (Refer to the item "7.
11 Process Electronic shutter 6. ITEMS CONTR OLLED BY THE SCREEN DISPLA Y MODE E. TRG MANU speed Syncro . scan. Pa r tial read Tr igger (1P SNR/SR) Tr igger (PW SNR/SR) 1P e xposure time MODE MANU MOD.
12 E. TRG RR E. TRG E. TRG 1P SR 1P SNR E. TRG PW SR E. TRG PW SNR SS MANU AWB WHT BAL OFF MANU OFF SHAD. SHAD. MANU MANU PAGE PAGE PAGE PAGE EXT INT BAUD RATE SHUTTER GAIN PROCESS SYNC OPTION PAGE PAGE POWER ON DISP PAGE PAGE DISP DISP Video signal output Index menu Menues 7.
13 MANU AL : It is possible to select the e xposure time from elev en speed setting; OFF , 1/100s, 1/250s, 1/500s, 1/1000s, 1/2000s , 1/4000s, 1/10000s, 1/25000s, 1/50000s, 1/100000s . Note: When setting a rapid shutter speed, sensitivity degrades according to the speed.
14 • Sutter mode MANU, SS, E.TRG • Sutter speed setting OFF, 100 (1/100s), 250 (1/250s), 500 (1/500s) 1000 (1/1000s), 2000 (1/2000s), 4000 (1/4000s) 10000 (1/10000s), 25000 (1/25000s) 50000 (1/500.
15 • Sutter mode MANU, SS, E.TRG • Synchro. scanning setting • Partial scanning switch OFF/40fps/50fps/60fps/70fps/80fps/90fps/ E40fps/E50fps/E60fps/E70fps/E80fps/E90fps -- SHUTTER -- MODE SS SS OFF PART OFF <MODE = SS> Move up down by pushing MENU UP, DOWN Select the desired value by pushing DATA UP, DOWN (1.
16 -- SHUTTER -- MODE E.TRG E.TRG 1P SNR TRG.P EXP. 30ms PART OFF <MODE = E.TRG E.TRG = 1P SNR> • E.TRG mode • Partial scanning switch OFF/40fps/50fps/60fps/70fps/80fps/90fps/ E40fps/E50fps/E60fps/E70fps/E80fps/E90fps 1P SNR, 1P SR, PW SNR, PW SR, RR 0.
17 -- SHUTTER -- MODE E.TRG E.TRG 1P SR TRG.P EXP. 30ms PART OFF 0.01 ms 0.02 ms 0.4 ms 1 ms 20 ms 30 ms <MODE = E.TRG E.TRG = 1P SR> • E.TRG mode • Partial scanning switch OFF/40fps/50fps/6.
18 -- SHUTTER -- MODE E.TRG E.TRG PW SNR TRG.P PART OFF <MODE = E.TRG E.TRG = PW SNR> • Partial scanning switch OFF/40fps/50fps/60fps/70fps/80fps/90fps/ E40fps/E50fps/E60fps/E70fps/E80fps/E90fps Input trigger pulse : positive polarity Input trigger pulse : negative polarity • E.
19 -- SHUTTER -- MODE E.TRG E.TRG PW SR TRG.P PART OFF <MODE = E.TRG E.TRG = PW SR> • Partial scanning switch OFF/40fps/50fps/60fps/70fps/80fps/90fps/ E40fps/E50fps/E60fps/E70fps/E80fps/E90fps.
20 -- GAIN -- MODE MANU MANU 0dB • Gain mode MANU, OFF • Manual gain adjustment 0 dB to 18 dB (1 dB step) Move up down by pushing MENU UP, DOWN Select the desired value by pushing DATA UP, DOWN ( 2 ) GAIN (Video gain) When the image is dark even if the lens iris is open, change the gain (video gain) to get the proper video le vel.
21 ( 3 ) WHT B AL (White balance) WHT BAL has two modes; AWB , MANU. Mov e the " → " to MODE, push the [DA T A UP], [D A T A DO WN], and select one of the two modes between A WB and MANU . (3. 1) Changing the setting in AWB (A utomatic White Balance) mode (a) Changing color temperature setting 1 Mov e the " → " to C.
22 ( 4 ) PROCESS • Gamma Correction (GAMMA) Select either OFF or ON of Gamma Correction. • Master P edestal (M. PED) Adjust the P edestal level of each RGB . •R P edestal (R. PED) Adjust the P edestal level of Red. •B P edestal (B. PED) Adjust the P edestal level of Blue .
23 • Serial baud rate setting 9600, 19200 -- OPTION -- BAUD RATE 9600 Move up down by pushing MENU UP, DOWN Select the desired value by pushing DATA UP, DOWN (4. 5) Changing the shading correction mode 1 Mov e the " → " to SHAD . by pushing [MENU UP], [MENU DOWN] b uttons.
24 7. 3 Synchro. Scan Operation The shutter speed can be set by the horizontal scanning period (1H) or by the fr ame. ( 1 ) Setting by 1H 1H/796H ~ 795H/796H stands for the setting b y the 1H and the shutter speed can be set by the 1H (43.05 µ s). When operating P ar tial Scannig, the number’ s listed below can be used for setting.
25 About 1 µ s External VD IN* 1 External HD IN* 1 (Internal VD) Tr igger* 1 About 1H Negative polarity mode P ositive polarity mode Exposure period* 2 Exposure period* 2 RGB data (video interval ima.
26 About 1 µ s Exposure completion 0 to 1H* 3 Exposure period* 2 Tr igger* 1 Negative polarity mode P ositive polarity mode (Internal VD) RGB data (video interval image) FV AL LV AL, DVA L 28H ( Pa r.
27 ( 3 ) PW SNR (Pulse width trig g er SYNC-NON RESET) The trigger input to CC1 of the DIGIT AL ter minal dev elops 1 frame images. (3. 1) Pulse Width T rigger SYNC-NON RESET Picture Output Timing *1:.
28 ( 4 ) PW SR (Pulse width trig g er SYNC-RESET) The trigger input to the CC1 of the DIGIT AL ter minal dev elops 1 frame images. (4. 1) 1 Pulse Width T rigger SYNC-RESET Picture Output Timing *1: Ex.
29 ( 5 ) RR (Reset restart) Input of an external reset-restart signal (CC4 of the DIGIT AL terminal: External VD input) permits one screen of information to be output at an arbitrary timing.
30 7. 5P artial Read 1/29.2s (796H) Video interval image 1/40s (580H): When 40fps is selected 1/50s (465H): When 50fps is selected 1/60s (387H): When 60fps is selected Video interval image 1/70s (332H): When 70fps is selected 1/80s (290H): When 80fps is selected 1/90s (258H): When 90fps is selected CC2 ‘L’ ‘H’ E.
31 External Sync. signal Match the phase. LVAL signal output 7. 6 External Sync When using the unit with an e xternal sync signal, input HD and VD to CC3 and CC4 of the DIGIT AL ter minal. When the external sync signal is input, the camera automatically s witches its sync from the inter nal sync to the e xternal sync.
32 8. INPUT OUTPUT SIGNAL SPECIFICA T OINS 5H 21H (P ositive polarity mode) (Negative polarity mode) More than 2 µ s More than 2 µ s 2.0 µ s 5.0 µ s ( 4 ) External HD/VD Input Phase Specifications 100 100 External HD rising edge Center Unit : Clock 1 clk=33.
33 9. OUTPUT W A VEFORM TIMING CHAR T ( 1 ) Horizontal Output Wa veform Timing Chart 246 clk 40 clk CLK=33.9 ns (29.5 MHz) 164 clk 29 clk 3 clk 5 clk 33.
34 10. SPECIFICA TIONS Po w er supply Po w er consumption Pick-up system Image sensor Scanning System Video output pix els Pixel cloc k frequency Sync signal frequency Sync system Sensitivity Minimum .
35 11. EXTERNAL APPEARANCE DIA GRAM Unit : mm [inch] * inch = mm/25.4 44 [1.73] 44 [1.73] 22 [0.87] 6.3 [0.25] 5.3 [0.21] 78 [3.07] 4.8 [0.19] 4.8 [0.19] 56 [2.20] 4.5 [0.18] 26 [1.02] 26 [1.02] 24.5 [0.96] 25 [0.98] 19.2 [0.76] 25 [0.98] 12 [0.47] 34 [1.
Limited W arranty – TOSHIB A CCD Camera The Imaging Systems Division of T oshiba America Information Systems, Inc. ("ISD") makes the f ollowing limited warranties with regard to this CCD Camera ("Product"). These limited warranties e xtend to the Or iginal End-User ("Y ou[r]").
デバイスToshiba ik-tf7uの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Toshiba ik-tf7uをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはToshiba ik-tf7uの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Toshiba ik-tf7uの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Toshiba ik-tf7uで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Toshiba ik-tf7uを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はToshiba ik-tf7uの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Toshiba ik-tf7uに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちToshiba ik-tf7uデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。