RS-485 Option Unit for TOSVERT VF-S7 Operation Manual Table of Contents 1. Overview ⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅.
1 1 Introduction Thank you for purchasi ng the “RS-485 Option Unit” for To shiba’s TOSVERT VF-S7 series ASD. Read the safety precautions in the VF-S7 Instruction Manual before powering up your VF-S7 unit. The S7 series has a built-in se rial communication port.
2 2 Carefully read the following notes Safety precautions There are warnings and caution s appearing on the ASD and in its operation man ual. Carefully read those warnings and cautions because they are very important not only for safe and correct ope ration but also for preventing the equipment and operato rs from getting damaged or injured.
3 3 CAUTION ON OPERATION DANGER! PROHIBITED ? ? Do not wipe the unit with wet cloth. Not following this instruction coul d cause electrocution. Do not pull the communication cable, othe rwise malfunctions or troubles could result. CAUTION ON DISPOSING OF OPTION UNIT CAUTION! MANDATORY ? Dispose of the used unit as industrial waste.
4 4 1. Overview By using RS-485 Option Unit, a network can be co nstructe d that allows communication between a host computer and multiple ASD units. A maximum of 32 Option Units can be connected o n the same network. And two ASDs can be conne cted to one Option Unit.
5 5 3. Names and functions of main parts Connector terminal (removal side ) • Wire size (shielded twisted-pai r cable recommended) Bare wire (without stick lug) : 0.2~1.5mm 2 Phoenix Contact TWIN terminal : (wire size belo w) × 2 Part number: AI-TWIN2 × 0.
6 6 4. Connection and start-up Connect the ASD with a host computer according to the procedu re mentioned below. Procedure (1) Set the communication speed to SW on the RS-485 Option Unit. (2) Connect terminating resistor in both ends of units. The RS-485 Option Unit has internal terminating resistor.
7 7 Cable connection R R T T S S X X X X G H A B A B I E L D SW INVERTER 1 INVERTER 2 RS485 OPTION UNIT Host Computer 1.Transmit positive line (TXA) 2.Transmit negative line (TXB) 3.Receive positive line (RXA) 4.Receive negative line (RXB) 5.Signal line ground (SC) 6.
8 8 5.0 5.Dimensions Dimensions of the RS-485 Option Unit (with connector terminal (removal side)) are shown b elow. Make sure a space for conn ecting cables. Use M3 screws to install. 45 ° 3.2hole 2.8 13.5 19.6 15.9 1.0 1.0 13.2 60.0 28.0 13.5 88.0 1.
9 9 6.Communication parameters Function Parameter Adjustable range Default value Communication speed F800 0 1 2 3 : : : : 1200bps 2400bps 4800bps 9600bps 3 Parity F801 0 1 2 : : : NONE EVEN ODD 1 ASD .
デバイスToshiba RS-485の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Toshiba RS-485をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはToshiba RS-485の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Toshiba RS-485の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Toshiba RS-485で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Toshiba RS-485を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はToshiba RS-485の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Toshiba RS-485に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちToshiba RS-485デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。