STE 58769– INSTRUCTION MANUAL TOSHIBA MACHINE'S FA SCHOOL TEXTBOOK FOR ROBOT TRAINING COURSE INDUSTRIAL ROBOT SR–H SERIES (ROBOT CONTROLLER: SR7000) May, 1998 TOSHIBA MACHINE CO.
STE 58769 – 2 – Preface The training session you are going to attend th is time is the FA school robot course. This textbook describes the robot language and basic operating procedures for the user who will operate the SR–H series industrial r obot (robot controller SR7000) in his plant or factory.
STE 58769 – 3 – Industrial Robot Training Schedule C Course (SR–H Robot): 2.5 Days Time Descriptions Place 1st day 13:30 ~ 13:40 Greetings at starting the course. Classroom 13:40 ~ 15:00 Explaini ng the outline. Classroom 15:00 ~ 15:15 Break 15:15 ~ 16:25 Explaining the programming.
STE 58769 – 4 – Robot SR–654HSP Robot controller SR7000 Teach pendant.
STE 58769 – 5 – Table of Contents Page 1. General De scriptions ...................................................................................... 7 1.1 Basic Robot and Controlle r ..............................................................
STE 58769 – 6 – Page 5. Maintenance and Inspecti on ........................................................................... 85 5.1 Maintenanc e Schedule ......................................................................... 85 5.2 Maintenance/In spection Ite ms.
STE 58769 – 7 – 1. General Descriptions 1.1 Basic Robot and Controller a) Names of the parts of the robot The SR-H series is a group of robots having four degrees of freedom.
STE 58769 – 8 – b) Names of the parts of the controller (1) Controller ON OFF START STOP CYCLE STOP MANU INT EXT FAULT POWER SERVO POWER EMERGENCY BATTERY ALARM J1 J2 PC FDD TP C.
STE 58769 – 9 – 14) Master mode key switch: switch to select a robot mode EXT: External automatic mode INT: Internal automatic mode MANU: Manual mode 15) Power lamp 16) Fault lamp: controller’s fault lamp 17) Buzzer: it sounds continuously when a fault is detected (since built in, it is not visible from outside).
STE 58769 – 10 – 6) Delete key: Key to delete a letter on which the cursor is placed. 7) Bs (backspace) key: Key to delete a letter just before the cursor.
STE 58769 – 11 – c) Composition of robot system Basic composition: Composed of the r obot body, controller, teaching pendant, and the FDD unit ON OFF START STOP CYCLE STOP MANU INT EXT FAULT POWER SERVO POWER EMERGENCY BATTERY ALARM J1 J2 PC FDD TP C.
STE 58769 – 12 – Teach pendant: Detachable from the connector and usable for multiple robots commonly. Inserting a dummy plug (accessory) allows automatic operation without the teaching pendant. Body cable: 3 cables. Standard cable is 5 m long. Optional cables can be 30 m at the maximum.
STE 58769 – 13 – 1.2 Coordinate Sy stem of the Robot Coordinate systems include the world, base, tool and workpiece coordinate systems. In the initial state, the world and wo rkpiece coordinate systems match the base coordinate system, and the tool coordinate system is a coordinate system whose origin is a hand mounting flange.
STE 58769 – 14 – Zt A A 0B ZB XB YB Base coo rd in ate system T ool c oor d in ate system 0t Yt Xt Zw Yw 0w Xw W o r ld c oo rdi na t e system W o r k c oo r dina t e s y s t em Yw 0w Xw Zw Note) A plural num ber of work coordinate system and tool coordinate system can be s et.
STE 58769 – 15 – 1.3 External Input/Output Signals a) External interface Panel is separated (option). Powe r supply TC200/term inal bl ock I/O For serial communi cation External I/O and operation .
STE 58769 – 16 – a) Input output signals 1) External operation input signal (CN5) External operation input signals are thos e to control the start and stop of the robot controller SR7000 from exter nal equipment such as a sequencer.
STE 58769 – 17 – 2) External operation output signal (CN6) External operation output signals are those which output operating conditions of the robot controller SR7000. • When input signals such as "servo off" and "emergency stop" are open, "servo on" is not feasible.
STE 58769 – 18 – 3) External output signals (CN12) External input output signals are t hose which input and output the operating condition of the robot controller SR7000. • User output is open collector output with a capacity of DC 24 V, 100 mA.
STE 58769 – 19 – 4) Auxiliary input and output signals DC 24 V wires, including five for input signals from sensors and 4 for control output signals to electromagnetic valves, are routed to the second arm of the robot, and allow the opening and closing of the hand and the monitoring of on/off of sensors.
STE 58769 – 20 – Pin Signal Co lo r name Co lo r Pin Signal name Signa l name Signal name Co lo r Co lo r Pin Pin Co l o r Co lo r Se nso r 1 2 3 4 5 6 7 GRP1 OP N GRP1 CL S GRP2 OP N GRP2 CL S WO.
STE 58769 – 21 – 1.4 Mode System Operation modes include the following. Master mode: Switching is made by the key switch on the operating panel. Sub mode: Switching is made by s pecifying the teaching pendant or system configuration file.
STE 58769 – 22 – 1.5 File a) File names File: Unit of storage for a program, etc. A maximum of 248 program files used by a user can be stored. However, memory is limited. 3, 000 program steps and 150 points of position data are a rule of thumb fo r measuring the size of a file.
STE 58769 – 23 – 3) System configurat ion file "CONSTRC.SYS." File storing an optional configuration of the robot, equipment connected to the serial port, settings of signals used for se lecting files by external signals. (When necessary, users may change the content.
デバイスToshiba SR-H Seriesの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Toshiba SR-H Seriesをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはToshiba SR-H Seriesの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Toshiba SR-H Seriesの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Toshiba SR-H Seriesで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Toshiba SR-H Seriesを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はToshiba SR-H Seriesの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Toshiba SR-H Seriesに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちToshiba SR-H Seriesデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。