No. MIIXR0002EAC DICOM CONFORMANCE STATEMENT MEDIA STORAGE FOR TOSHIBA DIGITAL FLUOROGRAPHY SYSTEM MODEL DFP-2000A with XIDF-037A and XIDF-038A or SRS-1000A (MIIXR0002EAC) 2001.
No. MIIXR0002EAC IMPORTANT! (1) No part of this manual may be copied or reprinted, in whole or in part, without written permission. (2) The contents of this manual are subject to change without prior notice and without our legal obligation.
No. MIIXR0002EAC Table of Contents Page 1 INTRODUCT ION ................................................................................................................ 1 1.1 R EFERENCES ................................................................
No. MIIXR0002EAC 8.1.1 Media Storage Directory IOD Modules ................................................................ 9 8.1.2 Media Storage XA IOD Modules .......................................................................... 9 8.1.3 XA IOD Modules .
No. MIIXR0002EAC 1 Introduction This document is a DICOM Conformance Statement for Toshiba's Digital Fluorography Systems. It is intended to provide the reader with the knowledge of how to integrate this product within DICOM compliant equipments.
No. MIIXR0002EAC 1.3 Acronyms, Abbreviations and Sy mbols • ACC American College of Cardiology • ACR American College of Radiology • ASCII American Standard Code for Information Interchange • .
No. MIIXR0002EAC 2 Implement ation Model 2.1 Application Data Flow Diagram Transfer of X-r a y Examinat ion DICOM Recording CD-R Medium Review of X-r a y Examinat ion DICOM Reader Legend Applicati on Entity Local Real-W orld Activi ty File-set Creator (FS C) File-set Reader (FS R) Local Relationship Figure 1 2.
No. MIIXR0002EAC 2.2.2 DICOM Reader The DICOM Reader supports the following tasks: • Reads the DICOMDIR file that represent s the contents of t he data as recorded. • Displays the ordered list of patient and image identifying information or icon images.
No. MIIXR0002EAC 2.3.2 Operation 2.3.2.1 Transfer of X-ray Examination The operation for manual transfer of X-ray examination is described below: STEP-1: Select the images or the patient to be transferred. STEP-2: Request transfer. STEP-3: Insert the blank CD-R media.
No. MIIXR0002EAC 3 AE Sp ecifications 3.1 DICOM Recording Specification The DICOM Recording AE provides Standard Conformance to the DICOM Media Storage Service, File Format Class and t he Media Storage Application Profile.
No. MIIXR0002EAC 3.2.1 File Meta Information for the Application Entity The Application Entity Title is not relev ant because this DICOM Reader AE only reads CD-R media. 3.2.2 Real-World Activity 3.2.2.1 Real-World Activity - Review of X-ray Examination DICOM Reader AE acts as a FSR when chosen by the operator.
No. MIIXR0002EAC 5 Extensions, S pecializations, and Privatizations of SOP Classes and T ransfer Synt axes Not applicable to this product. 6 Configuration For the Digital Fluorography System, the configuration can be set.
No. MIIXR0002EAC 8 X-Ray Angiographic Information Object Definition 8.1 Entity Module Definitions The information modules for the X-Ray Angiographic devices are defined below. 8.1.1 Media Storage Directory IOD Modules Table 5 Object Module / key Reference Usage 1 DICOM File Meta Information 8.
No. MIIXR0002EAC 8.1.3 XA IOD Modules Table 7 Information Entity Module Reference Usage 1 Patient Patient Module 8.5.1 M Study General Study Module 8.5.2 M Study Patient Study Module 8.5.3 U Series General Series Module 8.5.4 M Equipment General Equi pment Module 8.
No. MIIXR0002EAC 8.2 DICOM File Meta Information 8.2.1 DICOM File Meta Information of Directory IOD Table 8 Attribute Name Tag Type Attribute Description File Preamble No Tag 1 Alw ays set DICOM Prefi.
No. MIIXR0002EAC 8.3.2 Directory Information Module Table 11 Attribute Name Tag Type Attribute Description Offset of the First Directory Record of the Root Directory Entity (0004, 1200) 1 Always set O.
No. MIIXR0002EAC 8.4.2 STUDY keys Table 13 Attribute Name Tag T ype Attribute Description Study Date (0008, 0020) 1 Alway s set Study Time (0008, 0030) 1 Always set Study Description (0008, 1030) 2 Le.
No. MIIXR0002EAC 8.4.4 IMAGE keys Table 15 Attribute Name Tag Type A ttribute Description Instance Number (0020, 0013) 1 Alway s set Image Type (0008, 0008) 1 Alway s set Image Date (0008, 0023) 3 Alw.
No. MIIXR0002EAC 8.5 XA Information Object Definisions 8.5.1 Patient Module Table 16 Attribute Name Tag Type Attribute Description Patient's Name (0010, 0010) 2 Always set except for urgent patie.
No. MIIXR0002EAC 8.5.4 General Series Module Table 19 Attribute Name Tag Type Attribute Description Modality (0008, 0060) 1 Always set ("XA") Series Instance UID (0020, 000E) 1 Alway s set S.
No. MIIXR0002EAC 8.5.7 Image Pixel Module Table 22 Attribute Name Tag Type Attribute Description Samples per Pixel (0028, 0002) 1 Always set (0x0001) Photometric Interpretation (0028, 0004) 1 Always s.
No. MIIXR0002EAC 8.5.11 X-ray Image Module Table 26 Attribute Name Tag Type Attribute Description Frame Increment Pointer (0028, 0009) 1C Always set (0x00181063) Image Type (0008, 0008) 1 Alw ays set .
No. MIIXR0002EAC 8.5.13 XA Positioner Module Table 28 Attribute Name Tag Type Attribute Description Distance Source to Detector (0018, 1110) 3 Always set [mm] Estimated Radiographic Magnification Fact.
デバイスToshiba XIDF-038Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Toshiba XIDF-038Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはToshiba XIDF-038Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Toshiba XIDF-038Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Toshiba XIDF-038Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Toshiba XIDF-038Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はToshiba XIDF-038Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Toshiba XIDF-038Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちToshiba XIDF-038Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。