Transition NetworksメーカーSCSCF30XX-10Xの使用説明書/サービス説明書
ページ先へ移動 of 7
* Typical maximum cable distance. Actual distance is dependent upon the physical characteristics of the network. Part Number Port One - Copper Port Two - Duplex Fiber-Optic SCSCF3011-100 75 ohm coax (BNC) ST, 1300 nm multimode 2 km (1.2 miles)* SCSCF3013-100 75 ohm coax (BNC) SC, 1300 nm multimode 2 km ( 1.
2 SCSCF30xx-10x 24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 Part Number Port One - Copper Port Two - Single Fiber Optic SCSCF3029-102 and -103 are intended to be installed in the same network where one is the local converter and the other is the remote converter.
4 SCSCF30xx-10x 24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 Installation -- Continued CAUTION: Wear a grounding device and observe electrostatic discharge precautions when setting the jumper. Failure to observe this caution could result in damage to, and subsequent failure of, the Device.
SCSCF30xx-10x 6 Operation After installation, the Device should function without operator intervention. Use the status LEDs to monitor the Device operation in the network. SDC Green on The coax link is up. Green flashing The coax link is in loop-back mode.
8 SCSCF30xx-10x 24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 Cable Specif ications -- Continued SCSCF3029-102 1310 nm (TX) / 1550 nm (RX) simplex SCSCF3029-103 1550 nm (TX) / 1310 nm (RX) simplex Fiber-optic Transmitter Power: min: -8.
10 SCSCF30xx-10x 24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 6. Is Data Transfer Failing? YES • Verify the local copper connection by starting a local copper loop-back (set the loop-back switch on the local Device to “CL”) and then use a bit error test unit at the local location to run a bit error test.
Trademark Notice All trademarks and registered trademarks are the property of their respective owners. Copyright Restrictions © 2001, 2004 Transition Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic, or mechanical - without written permission from Transition Networks.
デバイスTransition Networks SCSCF30XX-10Xの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Transition Networks SCSCF30XX-10Xをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはTransition Networks SCSCF30XX-10Xの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Transition Networks SCSCF30XX-10Xの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Transition Networks SCSCF30XX-10Xで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Transition Networks SCSCF30XX-10Xを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はTransition Networks SCSCF30XX-10Xの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Transition Networks SCSCF30XX-10Xに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちTransition Networks SCSCF30XX-10Xデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。