UnidenメーカーUH400SX-RMの使用説明書/サービス説明書
ページ先へ移動 of 36
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM I OWNER’S MANUAL UHF RADIO TRANSCEIVER UH400SX UH400SX-RM UH500SX UH500SX-RM uh400sx, uh500sx, uh400sx-RM, uhI I uh400sx, uh500sx, uh400sx-RM.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM II uh400sx, uh500sx, uh400sx-RM, uhII II uh400sx, uh500sx, uh400sx-RM, uhII II 1/2/08 1:31:21 PM 1/2/08 1:31:21 PM.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 1 Introduction Features ..................................................................................................................... ....................... 3 Preventive Maintenance ...
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 2 uh400sx, uh500sx, uh400sx-RM, uhSec1:2 Sec1:2 uh400sx, uh500sx, uh400sx-RM, uhSec1:2 Sec1:2 1/2/08 1:31:21 PM 1/2/08 1:31:21 PM.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 3 The Uniden UH400SX, UH400SX-RM, UH500SX and UH500SX-RM is designed to provide you with years of trouble free service. Its rugged components and materials are capable of withstanding harsh environments.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 4 Preventive Maintenance: The following system checks should be made every six to twelve months: Check the Standing W ave Ratio (SWR). Inspect the tightness of all electrical connections. Inspect the antenna coaxial cable for wear or breaks on the shielding.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 5 Controls and Connectors Rotary CHANNEL Selector MENU/ENTER - Menu and Select Button DUAL - Dual W atch MON - Monitor Button DCS/CTCSS - DCS and CTCSS T one Button MEM - Memory Scan Channels 1.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 6 Controls/Connectors UH400SX Rear View UH500SX Rear View Connectors 1 1. Power Input Connection (13.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 7 Controls/Connectors Controls and Connectors 15 CALL - Call T one Button 16 INST - Instant Channel Button 17 PTT - Push T o T alk Button 18 ME.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 8 Controls/Connectors Controls and Connectors 15 CALL - Call T one Button 16 INST - Instant Channel Button 17 PTT - Push T o T alk Button 21 MI.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 9 UH500SX and UH400SX LCD (not to scale) Remote MIC LCD 1. TX - T ransmit 2. DUAL - Dual W atch 3. SCAN - Scan mode 4. Channel Frequency 5. GS - Group Scan 6. INST - Instant Channel 7. PRI - Priority Channel 8.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 10 Included with your UHF CB Radio UHF CB Radio Owners Manual Microphone Hanger & Screws W ashers and spare fuse DC Power Cord with fuse Re.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 11 Optional Accessories External S peaker (MS100) DIN Mounting Kit (DMK8990) for compact models Remote LCD Speaker Microphone (RM100) Extension.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 12 Mounting Using the DIN-E Sleeve If you are unsure about how to install your UH500SX in your vehicle using the DIN-E sleeve, consult your automobile manufacturer , dealer , or a quali fi ed installer .
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 13 Removing the UH500SX from the DIN-E Sleeve If you plan to use the Rear MIC Jack or connect an external speaker , at a later time, you should plan to remove the UH500SX from the DIN-E sleeve. This is easily done using the provided Removal Keys.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 14 Connecting the Microphone FRONT MIC JACK Push the MIC plug at the end of the microphone into the MIC jack until the connection locks into place. Gently tug the MIC cord to test that the connection is locked.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 15 Mounting the MIC Hanger The Microphone Hanger comes in two parts. How and where you mount the MIC hanger will determine which parts to use. Conventional Mounting with Screws Use the front part of the MIC Hanger only .
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 16 Mounting the MIC Hanger MIC Hanger mounted over MIC Cable The curly cord of the Standard MIC and Remote SPK/MIC can extend up to 1.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 17 T urning on the Power Press and hold the ON/OFF control at the base or the [POWER] button on the Remote SPK/MIC. Setting the Manual Squelch (base only) T urn the outer ring of the SQ control at the base to adjust the Squelch.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 18 Setting the Auto Squelch The Auto Squelch feature is available only when the Remote SPK/MIC is connected.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 19 Monitor Press and hold [DUAL/MON] at the base or [SQL/MON] on the Remote SPK/MIC to open the squelch and receive all weak signals. Press and hold [DUAL/MON] at the base or [SQL/MON] on the Remote SPK/MIC again to cancel.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 20 Programming the Instant Priority Channel T urn the Rotary Channel Selector at the base or press on the Remote SPK/MIC to select the Priority Channel you prefer . Press and hold [INST] button on the microphone for 3 seconds to store the new setting.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 21 Using Repeater Channels UHF CB repeaters are used to retransmit or relay your signal. Repeaters will extend the range of your radio and overcome the shielding effect caused by solid obstructions.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 22 Operating the UHF CB Radio in Duplex Mode For this example we are adopting CH01 as the channel being used in your area for repeater use. 1. Press [MENU/ENTER] . The duplex setting fl ashes. 2.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 23 Open Scan (OS) Mode Allows continuous scanning of all selected channels. If an active channel is found, scanning will stop on that channel. If the received signal ceases, the unit will wait 3 seconds for the signal to return, otherwise scanning resumes.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 24 Priority W atch T o switch Priority Watch On/Of f; 1. Press [MENU/ENTER] two times. The Priority W atch setting fl ashes. 2. T urn the Rotary Channel Selector at the base or press on the Remote SPK/MIC to change the setting between ON or OFF .
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 25 40 RX Channels The radio has 40 receive only channels (CH41 to CH80) which can be programmed with frequencies ranging from 450-512MHz (in 12.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 26 Selecting the Call tone 1. Press [MENU/ENTER] four times. The call tone setting fl ashes. 2. T urn the Rotary Channel Selector at the base or press on the Remote SPK/MIC to change the setting between 1, 2, 3, 4 and 5.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 27 Busy Channel Lockout If the channel is already in use, you can prevent the UHF CB Radio from transmitting . This is particularly important when using CTCSS/DCS. 1. Press [MENU/ENTER] fi ve times.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 28 Operation CTCSS (Continuous T one Coded Squelch System) T urn the Rotary Channel Selector at the base or press on the Remote SPK/MIC the desired channel to use CTCSS. Press [DCS/CTCSS] . CTCSS icon appears.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 29 Beep On/Off 1. Press [MENU/ENTER] seven times. The Beep setting fl ashes. 2. T urn the Rotary Channel Selector at the base or press on the Remote SPK/MIC to change the setting between ON or OFF .
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 30 Operation LCD Contrast for Remote SPK/MIC The LCD Contrast option becomes available only when the Remote SPK/MIC is con- nected. 1. Press [MENU/ENTER] nine times. The LCD Contrast setting fl ashes.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 31 Channels 5 and 35 are used for emergency channels. CTCSS and DCS will not operate on these channels. Please follow these guidelines for channel use in Australia: • Channels 05 and 35 are Emergency Channels.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 32 CTCSS & DCS Code List uh400sx, uh500sx, uh400sx-RM, uhSec1:32 Sec1:32 uh400sx, uh500sx, uh400sx-RM, uhSec1:32 Sec1:32 1/2/08 1:31:30 PM .
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 33 UNIDEN UH400SX, UH400SX-RM, UH500SX and UH500SX-RM UHF CB TRANSCEIVER RADIO T wo Y ear Limited Warranty IMPORT ANT Evidence of the original purchase is required for warranty service.
UNIDEN Model UH400SX, UH400SX-RM, UH500SX, UH500SX-RM OM 34 © 2008 Uniden Australia Pty Limited/Uniden New Zealand Limited Printed in China UTZZ01940ZZ(0) uh400sx, uh500sx, uh400sx-RM, uhSec1:34 Sec1.
デバイスUniden UH400SX-RMの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Uniden UH400SX-RMをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはUniden UH400SX-RMの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Uniden UH400SX-RMの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Uniden UH400SX-RMで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Uniden UH400SX-RMを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はUniden UH400SX-RMの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Uniden UH400SX-RMに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちUniden UH400SX-RMデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。