Vermont CastingメーカーDVR28INの使用説明書/サービス説明書
ページ先へ移動 of 28
DO NOT ST ORE OR USE GASOLINE OR OTHER FLAMMABLE V APORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. WHA T TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building.
2 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace PLEASE READ THE INST ALLA TION & OPERA TING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a CFM Corporation fireplace. IMPORT ANT : Read all instructions and warnings carefully before starting installation.
20012301 3 Vermont Castings DVR28 Direct Vent Gas Fireplace This gas appliance must be installed by a qualified installer , preferably NFI or WETT (Canada) certified, in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment.
4 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace DVR28 Fireplace Dimensions Fig. 1 Fireplace specifications and framing dimensions. Finished W all Finished W all 1“ (25 mm) Min.
20012301 5 Vermont Castings DVR28 Direct Vent Gas Fireplace A) Flat on wall B) Cross corner C) **Island D) *Room divider E) *Flat on wall corner F) Chase installation Y) 6” minimum NOTE: (Fig. 4) ** Island (C) and Room Divider (D) installation is possible as long as the horizontal portion of the vent system (X) does not exceed 20’ (610 cm).
6 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace Sheet Metal Screws (8) Sheet Metal Screws (4) FP1785 W all Mounting Bracket Secured to W alll DVR28 Fig. 6 Secure fireplace to wall mounting bracket.
20012301 7 Vermont Castings DVR28 Direct Vent Gas Fireplace Restrictor Plate Installation The DVR28IN is shipped with a restrictor plate for ex- tended pipe runs other than straight out installations. A guide for usage is shown in Figure 10. NOTE: Some installations may require some adjust- ment by the installer for optimum flame appearance.
8 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace Y our fireplace is approved to be vented either through the side wall, or vertically through the roof. • Only CFM Corporation venting components specifi- cally approved and labelled for this fireplace may be used.
20012301 9 Vermont Castings DVR28 Direct Vent Gas Fireplace V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINA TION AIR SUPPL Y INLET AREA WHERE TERMINAL IS NOT PERMITTED H I Operable Operable Fixed Closed V B CFM145a DV T ermin Location 5/01/01 Rev .
10 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace Fig. 12 T ermination clearances. General Information Assembling V ent Pipes Canadian Installations: V enting system must be installed in accordance with the current CSA-B149.1 installation code.
20012301 1 1 Vermont Castings DVR28 Direct Vent Gas Fireplace The vent chart should be read in conjunction with the following vent installation instructions to determine the relationship of the vertical and horizontal dimensions of the vent system. 1.
12 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace STEP 1 Locate vent opening on the wall. T o locate hole center consult with appropriate fireplace dimensions, Page 4. Frame as shown below . Combustible W alls (Fig. 17) : Cut a 10 ³⁄₈ ”H x 9 ³⁄₈ ” W (264 x 240 mm) hole through the exterior wall and frame as shown.
20012301 13 Vermont Castings DVR28 Direct Vent Gas Fireplace V ertical Sidewall Applications Since it is very important for the venting system to maintain balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent configurations apply and must be strictly adhered to.
14 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace Below Grade Installations When it is not possible to meet the required vent ter- minal clearances of 12” (305 mm) above grade level a snorkel kit is recommended. This allows installation depth of down to 7” (178 mm) below grade level.
20012301 15 Vermont Castings DVR28 Direct Vent Gas Fireplace 1 2 3 4 1 2 3 4 1 + 2 + 3 + 4 = 270° FP1 179 Fig. 26 Maximum elbow usage. • A minimum of an 8’ (2.5m) vertical rise is required. • T wo sets of 45° elbow of fsets may be used within the vertical sections.
16 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace TWL101a T wist Lock Pipe 2/8/99 djt 3 #5 Sheet Metal Screws per Joint Sealant TWL101a Fig. 30 Roof flashing. Storm Collar Min. 2' (610 mm) FP1 185 Fig. 29 Minimum termination to roof clearance.
20012301 17 Vermont Castings DVR28 Direct Vent Gas Fireplace 7TDVRVT - Through the wall Rear V ent T ermination Starter Kit - Model 7TDVSK - Sidewall V enting (T wist Lock Pipe) Model 7FDVSK - Sidewal.
18 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace Glass Information Only glass approved by CFM Corporation should be used on this fireplace. • The use of any non-approved replacement glass will void all product warranties. • Care must be taken to avoid breakage of the glass.
20012301 19 Vermont Castings DVR28 Direct Vent Gas Fireplace Flame & T emperature Adjustment T o adjust Hi/Lo setting, push either the high or low con- trol button on remote control transmitter . Flame Characteristics It is important to periodically perform a visual check of the pilot and the burner flames.
20 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace Lighting & Operating Instructions For Fireplaces equipped with AF4000 Gas V alve A. This fireplace is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot by hand.
20012301 21 Vermont Castings DVR28 Direct Vent Gas Fireplace T roubleshooting AF4000 V alve If erratic system behavior is observed that cannot be resolved by the methods outlined below , ensure that there is not a transmitter with batteries installed that may be interfering.
22 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace T roubleshooting AF4000 V alve (continued) Pilot will not light/stay lit • V erify the gas supply is turned on. • V erify the receiver is receiving the signal from the transmitter by listening for a beep from the receiver when ON is pressed on the transmitter .
20012301 23 Vermont Castings DVR28 Direct Vent Gas Fireplace • Ensure the CONTINUOUS PILOT switch on the control module (Fig. 36) is set to OFF . • V erify the gas supply is turned on. • Ensure the pilot flame will ignite. If not, see pilot flame troubleshooting above.
24 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace Burner and Burner Compartment It is important to keep the burner and the burner compartment clean.
20012301 25 Vermont Castings DVR28 Direct Vent Gas Fireplace CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. DVR28IN (GFYN4G0) 5 4 12 7 6 3 2 8 9 10 1 1 1 13 12301 DVR28 parts 3/07 14 15 17 16 Ref.
26 20012301 Vermont Castings DVR28 Direct Vent Gas Fireplace Optional Accessories Curve Face Kit Model # Color ICVCTK04 Rustic Bronze ICVCTK05 Charcoal Screen Door Kit Model # ICVCSTK.
20012301 27 Vermont Castings DVR28 Direct Vent Gas Fireplace BASIC W ARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new V ermont Castings or Majestic .
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www .cfmcorp.com CFM Corporation Efficiency Ratings Model EnerGuide Ratings Steady State (%) D.
デバイスVermont Casting DVR28INの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Vermont Casting DVR28INをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはVermont Casting DVR28INの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Vermont Casting DVR28INの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Vermont Casting DVR28INで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Vermont Casting DVR28INを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はVermont Casting DVR28INの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Vermont Casting DVR28INに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちVermont Casting DVR28INデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。