Radiance V ent Free Gas Heater Model RUVSOD: 3357, 3358, 3370 thru 3379 20004555 9/05 Rev . 12 Homeowner ’ s Installation and Operating Manual INST ALLER: DO NOT DISCARD THIS MANUAL - LEA VE FOR HOMEOWNER D E S I G N C E R T I F I E D This is an unvented gas-fired heater .
2 Rad iance V e n t- F ree G a s H ea te r 20004555 Installation and Operating Instructions ...................................................................................... 3 Stove Dimensions .....................................................
3 Rad iance V e n t- F ree G a s H ea te r 20004555 Installation & Operating Instructions In order to ensure safe and effective installation, this unit must be installed only by a qualified agenc.
4 Rad iance V e n t- F ree G a s H ea te r 20004555 31" (787mm) 29 " (756mm) RADIANCE 18 " (465mm) 1 1" (279mm) 28 " (717mm) 6 " (165mm) 4555 RUVSOD specs 7/01 Drawing Not to Scale 4555 Supply Inlet Fig.
5 Rad iance V e n t- F ree G a s H ea te r 20004555 Clearance Requirements Minimum Clearances to Combustible Materials Maintain clearance, (empty space), between combus- tible materials and the heater as specified below . Hearth Requirements The Radiance Unvented heater must be installed on rigid flooring.
6 Rad iance V e n t- F ree G a s H ea te r 20004555 Firebox weight / shipping 175 lbs. The installation of your Radiance stove must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1/NFP A 54 - latest edition.
7 Rad iance V e n t- F ree G a s H ea te r 20004555 V ent Free Features The Radiance RUVSOD, Model Nos. 3357, 3358, 3370 thru 3379, is an unvented gas heating appliance tested and listed to the ANSI standard Z21.
8 Rad iance V e n t- F ree G a s H ea te r 20004555 WARNING This heater shall not be installed in a confined space unless provisions are made for adequate combustion and ventilation air .
9 Rad iance V e n t- F ree G a s H ea te r 20004555 Read these instructions thoroughly before starting the assembly . Follow procedures in the order given. Inspect the stove for damage before starting the assembly . Do not install this stove if any damage is evident.
10 Rad iance V e n t- F ree G a s H ea te r 20004555 Install Optional Fan It is easiest to install the optional fan kit #2767/FK26, before the stove is moved to its final location or con- nected to the gas line. The fan consists of a blower assembly and a rheo- stat switch that are connected by a wire harness.
1 1 Rad iance V e n t- F ree G a s H ea te r 20004555 4. Attach the fan assembly to the fan bracket provided in the log box. Use #10 sheet metal screws provided with fan kit. Do not remove finger guard screws.(Fig. 10) 5. Connect snapstat leads. Disconnect the snapstat module from the leads inside the snapstat bracket.
12 Rad iance V e n t- F ree G a s H ea te r 20004555 MO TOR SNAPST A T ON/OFF RHEOST A T WHT WHT BLK BLK BLK GR N BLK POWER ST19 6 FK26 fan di angram 1 1/ 99 Fig.
13 Rad iance V e n t- F ree G a s H ea te r 20004555 Glass & Catalyst Installation CAUTION: Air shutter must be removed when installing glass and catalyst for proper operation. 1. Remove left and right log bracket assembly by unfastening the two screws which hold the burner in place.
14 Rad iance V e n t- F ree G a s H ea te r 20004555 Install Log Set 1. Remove the logs from their packaging, and inspect each piece for damage. DO NOT INST ALL DAM- AGED LOGS. 2. Ins tall the r ear left log by placing it on the sheet metal shelf at the back of the firebox.
15 Rad iance V e n t- F ree G a s H ea te r 20004555 5. Loosely sprinkle the lava rocks directly on top of the burner just behind decorative grate. (Fig. 25) Use the lava rock to cover brackets on the burner . Do not place lava rocks toward back of burner .
16 Rad iance V e n t- F ree G a s H ea te r 20004555 Operation The Radiance is shipped with the operable door front plate. The stove may be operated with the doors either open or closed. T o open the front doors, insert the handle provided into the door latch stub and turn it to the right and up.
17 Rad iance V e n t- F ree G a s H ea te r 20004555 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to “OFF”. Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. T urn off all electrical power to the fireplace.
18 Rad iance V e n t- F ree G a s H ea te r 20004555 T roubleshooting Follow these procedures in the order presented. WARNING TURN OFF HEA TER AND ALLOW T O COOL COMPLETEL Y BEFORE SERVICING. CONDITION POSSIBLE CAUSE SOLUTION No spark at pilot when Ignitor is operated.
19 Rad iance V e n t- F ree G a s H ea te r 20004555 T roubleshooting cont’d. CONDITION POSSIBLE CAUSE SOLUTION Pilot lights but flame goes out when Control Knob is released. 1. Control Knob not fully depressed or held in long enough. 2. Gas supply line shut-off valve is not fully open.
20 Rad iance V e n t- F ree G a s H ea te r 20004555 The following procedures will help ensure that your heater continues to perform safely and efficiently . Firebox Cleaning and Inspection Cleanliness is critical to correct operation of the heater .
21 Rad iance V e n t- F ree G a s H ea te r 20004555 Catalytic Combustor The combustor should be cleaned annually to ensure optimal performance. Follow the procedure below . Remove the Combustor Module 1. Be sure the heater is COLD. 2. Re mo ve th e f ron t pla te , t op gr il le and s cre en .
22 Rad iance V e n t- F ree G a s H ea te r 20004555 PILOT ON OFF PILOT ADJ L O H I 1a 1b 1c 2 4 6 7 13 3 4555 RUVSOD P ART S 7/24/01 djt 23 8 16 17 18 5 10a,b 21 19 9 20 24a,b, c,d 1 1a 1 1 b 15 2.
23 Rad iance V e n t- F ree G a s H ea te r 20004555 Radiance V ent Free Gas Heater (RUVSOD) Models 3357, 3358, 3370 thru 3379 (continued) Ref. Description RUVSOD 8. Handle Package, Ceramic w/Screw 0004342 9. Damper Steel Handle/Screw 5004265 10a. V alve NG Honeywell - VS84212003 10000235 10b.
24 Rad iance V e n t- F ree G a s H ea te r 20004555 Optional Accessories Fan Kits FK26 Fan The FK26 fan helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox tem- perature rises above and falls below a preset tempera- ture.
25 Rad iance V e n t- F ree G a s H ea te r 20004555.
26 Rad iance V e n t- F ree G a s H ea te r 20004555.
27 Rad iance V e n t- F ree G a s H ea te r 20004555 BASIC W ARRANTY CFM Specialty Home Products (hereinafter referred to collectively as the Company) warrants that your new V ermont Castings or Majes.
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www .majesticproducts.com • www .vermontcastings.com CFM Specialty Home Products.
デバイスVermont Casting thru 3379の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Vermont Casting thru 3379をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはVermont Casting thru 3379の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Vermont Casting thru 3379の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Vermont Casting thru 3379で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Vermont Casting thru 3379を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はVermont Casting thru 3379の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Vermont Casting thru 3379に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちVermont Casting thru 3379デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。