Vermont CastingsメーカーLHECDV30の使用説明書/サービス説明書
ページ先へ移動 of 32
10004894 1/07 Rev . 4 D E S I G N C E R T I F I E D CERTIFIED DO NOT ST ORE OR USE GASOLINE OR OTHER FLAMMABLE V APORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. WHA T TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building.
2 10004894 LHED V Ser ies Dir ect V ent I nse rt T able of Contents PLEASE READ THE INST ALLA TION & OPERA TING INSTRUCTIONS BEFORE USING THIS APPLIANCE. Thank you and congratulations on your purchase of a CFM Corporation fireplace insert. IMPORT ANT - Read all instructions and warnings carefully before starting installation.
3 10004894 LHED V Ser ies Dir ect V ent I nse rt This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA- B149.1 Installation codes for Gas Burning Appliances and Equipment. FOR U.S.
4 10004894 LHED V Ser ies Dir ect V ent I nse rt N O P 1" M E F HEZC specs 1/03 U S R Q V T FP1248 Minimum fireplace opening 1/03 Q - Fireplace opening height R - Fireplace opening wid.
5 10004894 LHED V Ser ies Dir ect V ent I nse rt When the unit is installed into a woodburning fireplace, the minimum distance the mantel can be placed above the fireplace is governed by local building codes appli- cable to woodburning fireplaces. Consult local authori- ties having jurisdiction for these clearances.
6 10004894 LHED V Ser ies Dir ect V ent I nse rt Do not use this appliance if any part of it has been under water . Immediately call a qualified service technician to inspect the unit and replace any part of the control which has been under water . Natural LP Minimum Inlet Pressure 5.
7 10004894 LHED V Ser ies Dir ect V e nt I nse rt FP297 INST A VENT FREE R MODEL GAS SUPPL Y 8/24/96 1/2" Gas Supply 1/2" x 3/8" Shut Off V alve 3/8" Nipple 3/8" Union FP297 Fig.
8 10004894 LHED V Ser ies Dir ect V e nt I nse rt FP1330 Switch assy 4/03 Left Side Installation Right Side Installation On/Off Switch As- sembly Wiring from Millivolt Gas V alve Fig.
9 10004894 LHED V Ser ies Dir ect V e nt I nse rt Liner Installation The collar extending down from the termination base is the air intake connector . Be sure the flex vent, which is connected to this collar , is also connected to the labelled air intake flue collar on the fireplace.
10 10004894 LHED V Ser ies Dir ect V e nt I nse rt FP1280 RHEDV vent termination 1/03 Flue gas exits through the vent termination rain cap 1) Attach flexible pipe to rain cap 2) Secure with clamp 3) .
1 1 10004894 LHED V Ser ies Dir ect V e nt I nse rt Ceramic Refractory Installation 1. Remove front glass. 2. Remove logs from unit. 3. Remove refractory from package. Refractory are fragile and must be handled with care. Where at all possible, two hands should be used when handling.
12 10004894 LHED V Ser ies Dir ect V e nt I nse rt A B C High Temperature Sealant D FP1298 RHEDV vent components 2/03 V enting Components A B C High Temperature Sealant D FP1299 RHEDV vent compo.
13 10004894 LHED V Ser ies Dir ect V e nt I nse rt Operating Instructions General Glass Information Only ceramic glass approved by CFM Cor- poration may be used for replacement on this unit. 1. The use of substitute glass will void all product warranties.
14 10004894 LHED V Ser ies Dir ect V e nt I nse rt Flame Adjustment (RN/RP Models) For fireplaces equipped with HI/LO valves, flame adjustment is accomplished by rotating the HI/LO adjustment knob located near the center of the gas control.
15 10004894 LHED V Ser ies Dir ect V e nt I nse rt First Firing Upon completing the gas line connection, a small amount of air will be in the lines. When first lighting unit with pilot light, it will take a few minutes to purge them- selves of this air .
16 10004894 LHED V Ser ies Dir ect V e nt I nse rt 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to " OFF ". Do not force. 5. Close control access panel. 1. ST OP! Read the safety information above. 2.
17 10004894 LHED V Ser ies Dir ect V e nt I nse rt W ARNING: Before doing any gas control service work, remove glass front. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark ignitor will not light A. Defective or misaligned Using a match, light pilot.
18 10004894 LHED V Ser ies Dir ect V e nt I nse rt Gas Supply On Supply Line Hooked Up Shutoff Valve Open NO NO NO NO Lockout Has Engaged. Wait 60 Seconds And Try Again. For Spark At Electrode While Depressing Piezo — 1/8" Gap To Pilot Hood Needed.
19 10004894 LHED V Ser ies Dir ect V e nt I nse rt Instructions for RF C om fo rt C on tr ol Va lv e The Comfort Control V alve allows remote control of temperature, fan and flame appearance. NOTE: The antenna should hang in free air away from grounded metal.
20 10004894 LHED V Ser ies Dir ect V e nt I nse rt Delay Timer Mode The shut off delay timer has a maximum of 2 hours and a minimum of zero minutes. T o change the timer level, press the time key followed by an arrow key . Pushing the key once will change the timer by 10 minutes.
21 10004894 LHED V Ser ies Dir ect V e nt I nse rt LED Count Service Action 8 Replace valve 7 Confirm stepper motor connection exists 5 Confirm fan connection exists and works 4 Confirm gas type; jumper in place 3 Replace thermopiles 2 T urn fan ON NOTE: Some keys are not active.
22 10004894 LHED V Ser ies Dir ect V e nt I nse rt Light pilot burner Set manual switch to local or remote Release pilotstat knob T urn pilotstat knob from PILOT to ON If manual switch is set to LOCAL.
23 10004894 LHED V Ser ies Dir ect V e nt I nse rt Maintenance Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out.
24 10004894 LHED V Ser ies Dir ect V e nt I nse rt LHERDV20/LHECDV20 1a 1d 1b 1e LHERDV30/LHECDV30 1a 1d 1c 1e 1b 3 2 4 5 6a/b 7a/b 9 a/b 8a/b 19 14 16 18 10a/b 18 17 1 1a/b 12a/b 13a/b 15 20 .
25 10004894 LHED V Ser ies Dir ect V e nt I nse rt LHEDV Series (continued) Ref. Description LHERDV20 LHECDV20 LHERDV30 LHECDV30 1. Log Set Complete 10005332 10005332 10004866 10004866 1a. Log Rear Left 10005333 (JR7) 10005333 (JR7) 10004874 (KR22) 10004874 (KR22) 1b.
26 10004894 LHED V Ser ies Dir ect V e nt I nse rt Ref. Description LHER20 LHEC20 LHER30 LHEC30 LHE Series (continued) 37. Remote Switch (for RN or RP Units) 53606 53606 53606 53606 38. Remote Wire Harness w/T erminals (for RN or RP Units) 10002582 10002582 10002582 10002582 39.
27 10004894 LHED V Ser ies Dir ect V e nt I nse rt Optional Accessories Remote Controls Optional remote control units are available to control different functions of the appliance. Model Function(s) Controlled RC1 ON/OFF RC2 ON/OFF and T emperature IMTFK W all mounted thermostat control NOTE: These remote controls are for RN/RP units only .
28 10004894 LHED V Ser ies Dir ect V e nt I nse rt.
29 10004894 LHED V Ser ies Dir ect V e nt I nse rt.
30 10004894 LHED V Ser ies Dir ect V e nt I nse rt.
31 10004894 LHED V Ser ies Dir ect V e nt I nse rt BASIC W ARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new V ermont Castings or Majestic Gas Firepl.
Efficiency Ratings Model EnerGuide Ratings Steady State (%) D.O.E. Fireplace Efficiency (%) Fan-OFF Fan-ON (AFUE%) LHECDV20RN 61.3 69 72 65 LHECDV20RP 61.3 70 73 65 LHECDV20RFN 61.3 69 72 65 LHECDV30RFP 61.3 70 73 65 LHERDV20RN 59.7 69 N/A 64 LHERDV20RP 59.
デバイスVermont Castings LHECDV30の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Vermont Castings LHECDV30をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはVermont Castings LHECDV30の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Vermont Castings LHECDV30の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Vermont Castings LHECDV30で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Vermont Castings LHECDV30を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はVermont Castings LHECDV30の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Vermont Castings LHECDV30に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちVermont Castings LHECDV30デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。