w w w w w w . . w w i i n n e e m m a a t t e e . . c c o o m m WINE-MATE Split System Installation, Operation & Care Manual VINO2500SSR VINO4500SSR VINO6500SSR V V i i n n o o t t e e m m p p I I n n t t e e r r n n a a t t i i o o n n a a l l C C o o r r p p .
- 1 - TABLE OF CONTENTS Important Safety Info rmation…..........................................2 Features & Specifications.…………………….……………..3 Cellar Construction.…………………………….……………..6 Installer’s Instruction…………….
- 2 - Important Safety Information WARNING: • DO NOT USE A GROUND FAUL T INTERRUPTER (GFI). • A DEDICATED 20 OR 30 AMP CIRCUIT IS REQUIRED (2500-4500SSR OR 6500SSR).
- 3 - Features and Specifications • Wine-Mate split cooling systems VINO2500-6500SSR are designed and used to provide a cold temperature between 50~65 ° F for a properly insulated wine room at a normal environment. • The wine room will maintain hum idity of 50~70% RH even when the environment becomes dry and humid.
- 4 - NOTE: LEAVE MINIMUM 3” CLEARANCE FOR ELECTRICAL WIRING AND REFRIGERATION PIPING. Parts included: Condensing Unit (discharge and suction valves installed) + Liquid Filter + Liquid Indicator Evaporator Unit (liquid line solenoid va lve and expansion valve installed) Temperature Controller + Air Sensor Fig.
- 5 - Fig. 2 WM250-450SCU Condensing Unit Fig. 3 WM650SCU Condensing Unit.
- 6 - Fig. 4 Liquid Filter Fig. 5 Li quid Indicator.
- 7 - Cellar Construction This is only a guide and shall be c onsidered as minimum requirements. All interior walls and floors shall have a vapor barrier and a minimum of R11 insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum of R19 insulation.
- 8 - Installer’s Instruction Federal law requires that WINE-M ATE split cooling systems be installed by an EPA certified refrigeration technician. WINE-MATE split system is shipped as components and is ready for use only after a certified refrigeration technici an has properly in stalled, evacuated, charged and tested the system.
- 9 - 1. Condensing Unit • Place the condensing units WM250-650SCU in a properly ventilated location. If it is not, heat exhausted by the condensing unit will build up and the coolin g system will not operate properly. • Condensing unit shall be elevated to avoid possible flooding and shaded from direct sun.
- 10 - 1 - Process & Manometer; 2 – Receiver Di scharge or Compressor Suction 3 – Liquid Line or Suction Line; 4 - Pressure Control 3. Evaporator Unit • The WM25-45SFCR evaporator units sha ll be installed for rack mount with the air supply from the left front, t op or side and air return on the right front, top or side.
- 11 - 2) Use inverted siphons to prevent liquid from flooding back to the compressor and aid oil returning to the compressor. 3) Both discharge and suction valves must be in the middle positions during evacuating and charging. 4) Charge the system after pipe brazing, leak testing and evacuating.
- 12 - 13) Both discharge and suction valv es mu st be in the back positions before disconnecting evacuating and pressure gauges. Fig. 10 Expansion Valve The line sizes and refrigerant charges are listed as follows.
- 13 - B. PS2 Dual Control Fig. 12 Adjustable Pressure Control 7. Use of the encapsulated pressu re control (if applicable) Fixed suction pressure setting: Cut in = 32 psig; Cut out = 10 psig Fig.
- 14 - 10. Pressure, Superheat and Subcooling Readings CAUTION: THE VALVES MUST BE IN THE MIDDL E POSITIONS TO READ PROPERLY. Complaint Possible Causes a. High suction pre ssure and low head pressure Zero superheat and zero subcooling b. High suction pre ssure and low head pressure Low superheat and low subcooling c.
- 15 - Electrical Wiring CAUTION: • USE MINIMUM 14 GAUGE WI RES FOR POWER LINES. • IF EQUIPPED WITH LOW AMBIENT CO NDITION KIT, USE LOW AMBIENT TEMPERATURE WIRING DIAGRAMS. TURN OFF THE COMPRESSOR BEFORE POWER THE CONDENSING UNIT. ONLY TURN ON THE COMPRESSOR AFTER THE CONDENS ING UNIT HAS BEEN POWERED FOR 24 HOURS.
- 16 - Fig. 15 VINO6500SSR Elect rical Wiring Diagram.
- 17 - Fig. 16 Low Ambient Temperature VINO2500-4500SSR Wi ring Diagram.
- 18 - Fig. 17 Low Ambient Temperature VINO6500SSR Electrical Wiring Diagram.
- 19 - Temperature Control & Humidity Adjustment 1. Temperature Setting • Set the temperature at 55 ° F for the optimum aging of wine • On initial start-up, the time required to reach the desired temperature will vary, depending on the quantit y of bottles, temperature setting and surrounding temperature.
- 20 - 2.1 LED Functions LED MODE FUNCTION ON Compressor enabled Flashing Anti-short cycle enabled ON Defrost cycle enabled ON Fan enabled Flashing Fan delay after defrost enabled ON Alarm occurring ON Temperature measuring unit Flashing Programming mode 3) Alarm Signals 3.
- 21 - 5) Parameter Programming 1. Press the SET + keys for 3 sec until the “ °C” or “°F” LED starts blinking, then release the keys. 2. Press again the SET + keys for more th an 7sec until the Pr2 label will be displayed, then release the keys.
- 22 - Care Guide In general, always unplug system or di sconnect power while doing care. 1. Coil Cleaning • Clean the condenser coil regularly. Coil may need to be cleaned at least every 6 months. • Unplug the system or disconnect power. • Use a vacuum cleaner with an extended attachment to clean the coil when it is dusty or dirty.
- 23 - User’s Troubleshooting This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration service person, not is it comprehensive. Complaint Possible Causes Response 1.Unit not running a. No power b. Powe r cord unplugged c.
- 24 - running continually e. Malfunctioning fans f. Improper evaporator or condenser airflow g. Dir ty C ondenser h. Iced evaporator i. Sealed system problem j. Undercharge or overcharg e the exhaust side and leave minimum 1 foot clearance for the fresh air intake side e.
- 25 - 10.Noisy operation a. Mounting area not firm b. Loose parts c. Compressor overlo aded due to high ambient temperatures o r airflow restrict ion d. Malfunctioning components a. Add support to improve installation b. Check fans, cabinet wa shers, tubing contact and loose screws.
- 26 - Customer Support If you still have problems, please contact us at: Vinotemp International 17631 South Susana Road Rancho Dominguez, CA 90221 Tel: (310) 886-3332 Fax: (310) 886-3310 Email: info@vinotemp.
- 27 - Warranty Thank you for choosing a Vinotemp cooling unit. Please enter the complete model and se rial numbers in the space provided: Model_____________ _________________________ __ _________________ Serial No._________________ ____________________ _________________ Attach your purchase receipt to this owner’s manual.
- 28 - VINOTEMP will, at its discret ion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it will be returned freight collect.
デバイスVinotemp Wine-Mate VINO2500-2500SSRの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Vinotemp Wine-Mate VINO2500-2500SSRをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはVinotemp Wine-Mate VINO2500-2500SSRの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Vinotemp Wine-Mate VINO2500-2500SSRの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Vinotemp Wine-Mate VINO2500-2500SSRで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Vinotemp Wine-Mate VINO2500-2500SSRを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はVinotemp Wine-Mate VINO2500-2500SSRの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Vinotemp Wine-Mate VINO2500-2500SSRに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちVinotemp Wine-Mate VINO2500-2500SSRデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。