VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791 FORM 30805, Rev. A (8-95) MODEL CMR34 GAS CHEESEMEL TER ML-52198 INST ALLA TION & OPERA TION MANUAL.
— 2 — IMPORT ANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED.
— 3 — Installation, Operation and Care of MODEL CMR34 GAS CHEESEMEL TER KEEP THIS MANUAL FOR FUTURE REFERENCE GENERAL Your Vulcan-Hart Gas Cheesemelter is suitable for use in restaurant, commercial or institutional kitchens. The cheesemelter is produced with quality workmanship and material.
— 4 — LOCATION Do not obstruct the air flow into and around the cheesemelter. This air flow is necessary for proper combustion of gases and for ventilation of the cheesemelter. Do not obstruct the flow of flue gases from the flue duct of the cheesemelter.
— 5 — INSTALLATION CODES AND STANDARDS The cheesemelter must be installed in accordance with: 1. State and local codes. 2. In USA . . . National Fuel Gas Code, ANSI Z223.1 (latest edition) available from the American Gas Association, Inc., 1515 Wilson Blvd.
— 6 — 4. Replace back top(s) and top castings on range. 5. After unpacking, remove the rack, drip pan and drip pan insert from the cheesemelter. 6.
— 7 — Fig. 5 Fig. 6 5. Line up holes on top brackets. Attach self-tapping screw to each top bracket, and attach 3 / 8 -16 bolt to each top bracket. Bolt thread through weld-nut on rail (beam support). 6. Reassemble bottom cover on cheesemelter (8 screws).
— 8 — Standard cheesemelters for use with natural gas are equipped with fixed orifices and a pressure regulator with a preset outlet pressure of 6" W.C. (water column). Standard cheesemelters for use with propane gas are equipped with fixed orifices and a pressure regulator with a preset outlet pressure of 10" W.
— 9 — OPERA TION WARNING: THE CHEESEMELTER AND ITS PARTS ARE HOT. BE CAREFUL WHEN OPERATING, CLEANING OR SERVICING THE CHEESEMELTER. CONTROLS — (Fig. 9) Fig. 9 Burner Valve — The burner valve regulates the flow of gas throughout the cheesemelter.
— 10 — LIGHTING THE PILOT LIGHT 1. Turn on the main gas supply. 2. Turn on the burner valve and purge air from the line. Turn the burner valve off, wait five minutes. 3. Using a taper, light the pilots (Fig. 10). 4. If the pilots fail to light, turn off the gas, wait five minutes and repeat Steps 1 through 3.
— 11 — LOADING AND UNLOADING Place the rack in the desired position. Pull the rack out for loading. Load as quickly as possible and avoid spillage. Push the rack into place and cook for the appropriate time. Lower and pull the rack out for unloading.
— 12 — TROUBLESHOOTING PROBLEM Uneven heating Side burning Too much top heat Uneven heat side-to-side Uneven heat front-to-back Dried out products Pilot outage Poor ignition POSSIBLE CAUSES 1. Temperature too low 2. Improper operation of cheesemelter 3.
デバイスVulcan-Hart CMR34の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Vulcan-Hart CMR34をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはVulcan-Hart CMR34の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Vulcan-Hart CMR34の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Vulcan-Hart CMR34で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Vulcan-Hart CMR34を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はVulcan-Hart CMR34の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Vulcan-Hart CMR34に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちVulcan-Hart CMR34デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。