VBP SERIES FOOD HOLDING AND TRANSPOR T CABINETS MODELS VBP4 ML-126352 VBP7 ML-126353 VBP13 ML-126355 VBP15 ML-126356 VBP40 ML-126357 VBP7 I ML-126358 VBP13 I ML-126359 VBP15 I ML-126360 VBP77 ML-12635.
– 2 – T ABLE OF CONTENTS GENERAL ............................................................................................................................................. 3 INSTALLATION .........................................................
– 3 – Installation, Operation and Care of MODEL VBP SERIES FOOD HOLDING AND TRANSPORT CABINETS PLEASE KEEP THIS MANUAL FOR FUTURE USE GENERAL Vulcan-Hart Holding and Transport Cabinets are produced with quality workmanship and material.
– 4 – INST ALLA TION Before installing, verify that the electrical service agrees with the specifications on the rating plate located on the lower left corner. If the supply and equipment requirements do not agree, do not proceed with the installation.
– 5 – INSTALLATION CODES AND STANDARDS The cabinet must be installed in accordance with: In the United States of America: 1. State and local codes. 2. National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained from The National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
– 6 – Electrical Table Model Voltage Amp Phase Hz NEMA Plug VBP4 110/120 10 16 0 5-15 208/240 5.4 6-15 VBP7 110/120 10 16 0 5-15 208/240 5.4 6-15 VBP13 110/120 10 16 0 5-15 208/240 5.4 6-15 VBP15 110/120 10 16 0 5-15 208/240 5.4 6-15 VBP40 110/120 16.
– 7 – WIRING DIAGRAMS VBP4, VBP7, VBP13, VBP15, VBP40, VBP7 I , VBP13 I , VBP15 I.
– 8 – VBP77, VBP77 I.
– 9 – VBP8H I , VBP12H I , VBP15H I.
– 10 – OPERA TION WARNING: THE CABINET AND ITS PARTS ARE HOT. BE VERY CAREFUL WHEN OPERATING, CLEANING OR SERVICING THE CABINET. CONTROLS Fig. 1 All Models (Fig.1) POWER INDICATOR LIGHT – Lit when power is supplied to cabinet. HEAT INDICATOR LIGHT – Lit when heat is supplied to cabinet.
– 11 – OPERATING CABINET 1. Connect electric power supply. • Power indicator light is lit. 2. If cabinet is a VBP8H I , VBP12H I , or VBP15H I , press ON/OFF switch ON. • Interior air circulating fans start. • Control/component compartment cooling fans start.
– 12 – Shutdown If cabinet is a VBP8H I , VBP12H I , or VBP15H I , press ON/OFF switch OFF. Extended Shutdown Unplug electrical power supply. Power indicator light will go off. CLEANING WARNING: UNPLUG ELECTRICAL POWER SUPPLY BEFORE CLEANING. Clean cabinet interior with a mild soap and water whenever food spill occurs.
デバイスVulcan-Hart VBP15 ML-126356の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Vulcan-Hart VBP15 ML-126356をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはVulcan-Hart VBP15 ML-126356の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Vulcan-Hart VBP15 ML-126356の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Vulcan-Hart VBP15 ML-126356で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Vulcan-Hart VBP15 ML-126356を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はVulcan-Hart VBP15 ML-126356の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Vulcan-Hart VBP15 ML-126356に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちVulcan-Hart VBP15 ML-126356デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。