WAGNERメーカー9140S, 9146, 9150, 9170, 9190の使用説明書/サービス説明書
ページ先へ移動 of 28
English Owner Owner ’ ’ s manual: s manual: Read this manual for complete instructions Read this manual for complete instructions 1-800-880-0993 W agner T echnical Service 1770 Fernbrook Lane, Plymouth, MN 55447 http://www .wagnerspraytech.com V isit us on the world wide web! T able of Contents Safety .
2 English Important Safety Information • Read all safety information before operating the equipment. Save these instructions HAZARD: INJECTION INJUR Y A high pressure paint stream produced by this e quipment can pierce the skin and underlying tissues, leading to serious injury and possible amputation.
3 English HAZARD: GENERAL C an cause severe injury or property damage. PREVENTION: • Read all instructions and safety precautions before operating equipment. • Follow all appropriate local, state, and national codes governing ventilation, fire prevention, and operation.
4 English Components and Description ON/OFF Switch ........... The ON/OFF switch turns the power to the sprayer on and off (O=OFF , l=ON). Suction tube .
5 English Components and Description 9146, 9150 9170 9190 GX-07 GX-07 GX-08 415 517 517 517 519 521 Y ellow (fine) 9140S GX-05 415 415 Y ellow (fine) White (medium) White (medium) 25 feet 25 feet 50 feet 50 feet This pump is available in two models: a stand model (9140S) and cart models (9146, 9150 shown below , 9170 and 9190).
Do not plug in the sprayer until setup is complete. 6 English Assembly WARNING • T wo adjustable wrenches • 3/16” Allen wrench T ools needed for assembly: I f you have one of the cart models (9146, 9150, 9170 or 9190), follow these assembly instructions.
7 English Before you begin - This section contains instructions that will be repeated throughout this manual. Always lock the trigger off when attaching the spray tip or when the spray gun is not in use.
8 English Purging and Priming the Sprayer All new units are performance-tested at the factory and are shipped with test fluid in the fluid section to prevent c orrosion during shipment and storage. If you have already used your pump, some water or solvent used in cleaning may remain in the fluid section.
O SPRAY PRIME 9 English Purging and Priming the Spray Hose 1. Unlock the spray gun and turn the PRIME/SPRA Y knob to PRIME. 2. PULL the trigger and aim the spray gun at the side wall of a waste container . If using oil-based materials, the s pray gun must be grounded while purging (see warning below).
10 English Good spray pattern Paint tailing pattern (pressure too lo w, clogged tip) 1. Switch the pump ON (l) . T urn the PRIME/SPRA Y knob to SPRA Y . T urn the pressure control dial to maximum pressure (+). The spray hose should stif fen as paint b egins to flow through it.
11 English Spraying T roubleshooting - Unclogging the Spray T ip Do not attempt to unclog or clean the tip with your finger . WARNING NOTE - Do not use a needle or other sharp pointed instrument to clean the tip.
12 English Spraying T roubleshooting - Cleaning the Spray Gun Filter The filter must be cleaned every time you use your sprayer . When using thicker spray materials, the filter might need to be cleaned more often. 1. Perform Pressure Relief Procedure, page 7.
13 English Call 1-800-880-0993 if you have any problems or questions regarding the cleaning of your sprayer . • When using latex materials, clean your sprayer and components with water .
14 English 5 . Unclip the return tube from the suction tube and place it into the waste container . T urn the PRIME/SPRA Y knob to PRIME. 8. While pulling the trigger , turn the PRIME/SPRA Y knob to SPRA Y to purge material from the hose back into the original container .
15 English 1. Lock the gun and remove spray tip assembly . Submerge suction set into a bucket with appropriate cleaning solution. 2. Place a waste container next to the original material c ontainer . Aim the spray gun into the side of the o riginal material container and hold the trigger .
16 English 1. Lock the gun and turn the pump OFF (O) . 3. When suction set is clean, thread the suction tube back into the inlet valve, and replace the return tube onto the return tube fitting. Replace clip. 4. Submerge the suction set into a bucket of NEW cleaning solution.
17 English 1. Make sure the pump is switched OFF (O). Make sure the PRIME/SPRA Y knob is turned to PRIME. Unplug the sprayer . 2. Remove spray gun from the paint hose using adjustable wrenches. (b) (c) (a) 3. Remove filter from spray gun (refer to Cleaning the Spray Gun Filter , page 12).
18 English Follow these steps when using latex materials only . If using materials that are oil-based, follow the Cleanup - Oil-based materials and Long-T erm Storage steps. Shutdown 1. Lock the spray gun off. GX-08 GX-07 GX-05 2. Turn the PRIME/SPRA Y knob to PRIME.
19 English 1. Fill a cup or other container with separating oil (approximately 2 ounces) supplied with the unit and submerge the inlet valve into the oil. Light household oil can be substituted. 2. Place a rag over the spray hose port, and turn the switch ON (l) .
20 English (a) 1. Remove the suction set. 2. Unscrew the inlet valve assembly (a) from the sprayer . Visually inspect the inside and outside of the inlet valve a ssembly . Clean any paint residue with the appropriate c leaning solution. Cleaning or servicing the inlet valve may be required if the unit has priming problems.
21 English Fluid Section Seal Replacement Instructions Always wear protective eye wear while servicing the pump. Be sure to follow the Pressure Relief Procedure (page 7) when shutting the unit down for any purpose, including servicing or adjusting.
22 English T roubleshooting / Maintenance P roblem A. The sprayer does not start. B. The sprayer starts but does not draw in paint when the PRIME/SPRA Y knob is set to PRIME. C. The sprayer draws up paint but the pressure drops when the gun is triggered.
67 English Français Español Parts List • Liste de pièces • Lista de piezas Model GX-05 spray gun Item Part # Description Quantity 1 050101 1 Guard Assembly ...................................1 2 0501415 T ip, 415 ...............................
68 English Français Español Parts List • Liste de pièces • Lista de piezas Model GX-08 spray gun Item Part # Description Quantity 1 0501517 Tip, 517 ......................................................1 2 050101 1 Guard assembly .............
69 English Français Español Parts List • Liste de pièces • Lista de piezas Suction set Item Part # Description Quantity 1 0516219 Suction set (9140S) ..............................1 0516218 Suction set (all cart models) .................1 2 0512371 Return tube (9140S) .
70 English Français Español Parts List • Liste de pièces • Lista de piezas 1 6 3 5 2 7 8 9 10 11 4 Item P art # Description Quantity 1 0512336 Stand assembly (9140S) . . . . . . . . . . . . . .1 2 9885546 Plug . . . . . . . . . . . . . . . . . .
71 English Français Español Accessories • Accessoires • Accesorios Part # Description 0516913 Separating Oil 0154830 Hose, Whip End, 5’ x 3/16” 0 270192 Hose, Wireless, 25’ x 1/4" 029.
72 English Français Español W arranty • Garantié • Garantia GARANTIE LIMITÉE MA TÉRIEL DE PUL VÉRISA TION DE PEINTURE SANS AIR C e produit, fabriqué par W agner Spray T ech Corporation (Wag.
デバイスWAGNER 9140S, 9146, 9150, 9170, 9190の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
WAGNER 9140S, 9146, 9150, 9170, 9190をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWAGNER 9140S, 9146, 9150, 9170, 9190の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。WAGNER 9140S, 9146, 9150, 9170, 9190の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。WAGNER 9140S, 9146, 9150, 9170, 9190で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
WAGNER 9140S, 9146, 9150, 9170, 9190を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWAGNER 9140S, 9146, 9150, 9170, 9190の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、WAGNER 9140S, 9146, 9150, 9170, 9190に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWAGNER 9140S, 9146, 9150, 9170, 9190デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。