Wagner SprayTechメーカーGM 2000 EACRの使用説明書/サービス説明書
ページ先へ移動 of 36
Operating Manual GM 2000 EACR - EN GM 2000 EACF - EN 0179 887 GB Edition 03/98 Electrostatic AirCoat Spraygun, with flat or round jet tips.
.
CONTENTS Paragraph Chapter.Page 1 INTRODUCTION 1.1 1.1 Using the manual 1.1 1.2 SAFETY REGULATIONS 1.2 1.3 PTB Conformity certification 1.4 1.4 Product liability and guarantee 1.5 1.5 CE conformity 1.6 2 DESCRIPTION 2.1 2.1 Scope of supply 2.1 2.2 Technical data 2.
CONTENTS Paragraph Chapter.Page 7 ACCESSORIES 7.1 7.1 Round jet tip inserts 7.1 7.2 AirCoat flat tips 7.2 7.3 Filter (standard) 7.3 7.4 Long filter housing and filters 7.3 7.5 Hoses and fittings 7.3 7.6 Special tools 7.3 8 SPARE PARTS CATALOGUE 8.1 8.
1. INTRODUCTION This operating manual contains information and instruction for the operation, repair and maintenance of the spray gun. This equipment can be dangerous if it is not operated in accordance with this Opera- ting manual! Compliance with these instructions constitutes an integral component of the guarantee agreement.
1.2 SAFETY REGULATIONS The safety requirements for electrostatic hand spraying equipement are laid down in the following documents: (Germany) 1) ZH 1/250 Electrostatic enamelling with hand-held spraying equipment (Published by C. Heymanns-Verlag, Cologne) 2) ZH 1/406 Guidelines for jet stream equipment (spraying devices) (Published by C.
1.2.4 Protective breathing masks Although the E-Static AirCoat spraying procedure produces very little mist, it is not completely mist free. There are, in fact, few paint particles to be found in the air.
1.3 PTB Conformity certification GM 2000 EAC - EN 1.4.
1.4 Product liability and guarantee Warranty 12 months / 6 months for multi-shift operation This equipment is covered by the following manufacturing warranty: All parts which prove unusable or the use.
1.5 CE Conformity 1.5.1 Short explanation CE = Communauté Européenne: Products identified with the CE mark have been manufactured and checked according to EU guidelines.
2. DESCRIPTION 2.1 Scope of supply Part No. Quantity Description 0179 018 1 Electrostatic AirCoat spray gun GM 2000 EAC R, with round jet tip R 15 . or 0179 019 1 Electrostatic Air coat spray gun GM 2000 EAC F, without flat jet tip.
● The trigger can be used to activate, one after the other, the various functions of the spray gun. An increase in the tension needed to pull the trigger back will be felt at the position where the material valve opens. ● In order to overcome Faraday cages in corners, the high volta- ge can be switched off by flip- ping the HV switch (F) down.
2.3.2 AirCoat round jet process In the AirCoat process, high pressure of 30 to 150 bar is used to atomize the material. The AirCoat air at 0 to 2.5 bar produces a soft jet, which largely eliminates the problem of overlapping boundaries. The spray jet can be adjusted by turning the nozzle nut.
2.3.4 Electrostatic effect The spray gun produces an electrostatic field by means of the high voltage electrode. As a result, the particles of paint, which have been atomized by the spray gun, are carried to the earthed object by kinetic and electrostatic energy where they adhere, finely distributed, to the object being sprayed.
3. PREPARATION BEFORE STARTING WORK Caution The operating instructions and the safety regulations for the additional system components used must be read before starting-up . This spray gun must be used a part of an AirCoat-Electrostatic spraying system.
Empty page GM 2000 EAC - EN 3.2.
4. STARTING WORK, AND HANDLING Caution See SAFETY REGULATIONS in chapter 1. 4.1 Preparation ● Locking of spray gun! Turn locking nut clockwise until stop (viewed from back of gun) ● Check that spraying pressures are suitable. ● Check that all connections are tight and do not leak.
4.4 Cleaning of clogged round jet tips 1. By means of tip spanner (A), loosen tip insert (B) by a half turn. 2. Remove tip spanner and briefly pull trigger. Caution , never spray into an enclosed vessel. 3. After cleaning the tip retighten. 4.5 Exchange of Aircoat round jet tip insert (EAC round) 1.
4.7 Replacing AirCoat flat jet tips 1. Switch off control unit. 2. Relieve spray gun and system pressure! 3. Lock spray gun. Turn locking screw clockwise until stop. (look in spray- ing direction) 4. Unsrew cap ring (I) and remove air cap (H). 5. Remove AirCoat tip insert (F) and brush cleaning solvent until all tra- ces of paint are dissolved.
Empty page GM 2000 EAC - EN 4.4.
5. MAINTENANCE Caution See SAFETY REGULATIONS in chapter 1. Attention The spray gun and the system must be cleaned every day. Use only the cleaning sol- vent recommended by the material manufacture. Never immerse the spray gun into the solvent. The following points must be observed before every maintenance works: ● Switch off control unit.
5.2 Dissassembly of AirCoat nozzle body (round jet) 1. Unscrew tip nut. 2. Remove nozzle body (3) with spanner (B) 3. Unscrew tip insert (1) with tip spanner (A) 4. Push threaded nozzle fitting (2) backwards out of the nozzle body (3). 5. Handle the round-jet tip insert (1) and threaded fitting (2) with care, do not clean with sharp metal objects.
5.4 Adjustment of the valve rod seal In case paint leaks at the valve rod near the trigger: 1. Pull trigger and throughly clean paint channel with solvent. 2. Tighten the sealing screw (A) ca- refully with universal spanner 3. If leaking continues, see chapter 5.
5.6 Exchange of paint channel ● if the round jet nozzle is fitted 1. Unscrew tip nut (1). 2. Unscrew tip body (2) with universal spanner. 3. Unscrew seal screw (3) with paint channel assembly tool. 4. Remove paint channel. Assemble in reverse order, use screw (3) again.
6. TROUBLE SHOOTING AND SOLUTIONS GM 2000 EAC - EN 6.1 Problem Insufficient material output Poor spray pattern Leaking air valve Poor wrap round or electrostatic effect Back spraying No electrostatic .
Empty page GM 2000 EAC - EN 6.2.
7. ACCESSORIES 7.1 Round jet tip inserts The round jet tips are especially suited to spray pipes, profiles and complex workpieces. Part-No. Marking Volume flow Jet width Recommended filter 1) 2) 0132 720 R 11 0.160 appr. 250 mm 0132 721 R 12 0.220 appr.
7.2 AirCoat flat tips AirCoat flat jet tips are used for fast, economic application of material to flat workpieces. Part Marking size Spraying Volume Jet Recommended number mm / inch angle flow 1) width 2) filter 0128 564 07.40 0.18-0.007 40 0.19 160 0128 550 09.
7.3 Filter (standard) 7.4 Long filter housing and and filters 7.5 Hoses and fittings 7.6 Special tools GM 2000 EAC - EN 7.3 Description Mesh Part No. for 1 pc. Part No. for 10 pcs. For use with nozzle sizes round flat Gun filter, red 180 0034 383 0097 022 R 11 - R 15 .
Empty page GM 2000 EAC - EN 7.4.
8. SPARE PARTS CATALOGUE 8.1 How to order spare parts? Always supply the following information to ensure delivery of the right spare part: Part No., description and quantity. The quantity need not be the same as the number given in the "Quantity" column.
8.3 Spare parts list GM 2000 EAC - EN 8.2 Item Part No. K Quantity Description 2 0179 354 1 Positioning bush 3 9900 962 1 Countersunk screw M3x12 4 0179 564 1 Data plate GM 2000 EAC R EN 4 0179 569 1 .
39 38 40 41 42 48 49 37 50 55 51 52 53 54 GM 2000 EAC - EN 8.3.
Empty page GM 2000 EAC - EN 8.4.
.
England / United Kingdom WAGNER Spraytech (UK) Lt. Telephone ++44 / (0)1295/ 265 353 Haslemere Way Telefax ++44 / (0)1295/ 269 861 Tramway Industrial Estate GB- Banbury OXON OX16 8TY E-Mail: enquiry@wagnerspraytech.co.uk Deutschland / Germany J. WAGNER GmbH Telephone ++49/ (0)7544 / 5050 Otto-Lilienthal-Str.
デバイスWagner SprayTech GM 2000 EACRの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Wagner SprayTech GM 2000 EACRをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWagner SprayTech GM 2000 EACRの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Wagner SprayTech GM 2000 EACRの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Wagner SprayTech GM 2000 EACRで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Wagner SprayTech GM 2000 EACRを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWagner SprayTech GM 2000 EACRの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Wagner SprayTech GM 2000 EACRに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWagner SprayTech GM 2000 EACRデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。