EGH-85 & 95 Series 4 PFG-6 & 7 Series 6 & 7 P art Number 550-110-031/0605 Control Supplement Standing Pilot Boilers Controls must only be installed by a W eil-McLain distributo r or other .
2 P art Number 550-110-031/0605 EGH-85 & 95 Series 4 and PFG-6 & 7 Series 6 & 7 This system is used on gas-fired boilers without vent dampers as shipped from the fact or y .
3 P art Number 550-110-031/0605 Control Supplement — Standing Pilot Boilers Hazard definitions and Note to the inst aller ................................................................................... .2 Control installation — EGH-85 & 95 water boilers .
4 P art Number 550-110-031/0605 EGH-85 & 95 Series 4 and PFG-6 & 7 Series 6 & 7 Control installation — EGH-85 & 95 water boilers.
5 P art Number 550-110-031/0605 Control Supplement — Standing Pilot Boilers Fo r your safet y , turn off electr ical power sup ply and turn off external gas supply val ve before attempting to w ork on the boiler . Failur e to c omply can cause seve re personal injur y , death or substantial pr oper ty damage.
6 P art Number 550-110-031/0605 EGH-85 & 95 Series 4 and PFG-6 & 7 Series 6 & 7 Control installation — PFG-6 & 7 water boilers.
7 P art Number 550-110-031/0605 Control Supplement — Standing Pilot Boilers Fo r your safet y , turn off electr ical power sup ply and turn off external gas supply val ve before attempting to w ork on the boiler . Failur e to c omply can cause seve re personal injur y , death or substantial pr oper ty damage.
8 P art Number 550-110-031/0605 EGH-85 & 95 Series 4 and PFG-6 & 7 Series 6 & 7 Control installation — EGH-85 & 95 steam boilers.
9 P art Number 550-110-031/0605 Control Supplement — Standing Pilot Boilers Fo r your safet y , turn off electr ical power sup ply and turn off external gas supply val ve before attempting to w ork on the boiler . Failur e to c omply can cause seve re personal injur y , death or substantial pr oper ty damage.
10 P art Number 550-110-031/0605 EGH-85 & 95 Series 4 and PFG-6 & 7 Series 6 & 7 Control installation — EGH-85 & 95 steam boilers.
11 P art Number 550-110-031/0605 Control Supplement — Standing Pilot Boilers Fo r your safet y , turn off electr ical power sup ply and turn off external gas supply val ve before attempting to w ork on the boiler . Failur e to c omply can cause seve re personal injur y , death or substantial pr oper ty damage.
12 P art Number 550-110-031/0605 EGH-85 & 95 Series 4 and PFG-6 & 7 Series 6 & 7 Lighting instructions — Robertshaw 7000ERHC FOR Y OUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS T O TURN OFF GA S T O THE APPLIANCE • Do not try to light any appliance.
13 P art Number 550-110-031/0605 Control Supplement — Standing Pilot Boilers T r oubleshooting V erify proper operation after servicing Never jumper (bypass) any device except for momentary testing as outlined in troubleshooting chart below . Substantial property damage and/or severe personal injur y could occur .
14 P art Number 550-110-031/0605 EGH-85 & 95 Series 4 and PFG-6 & 7 Series 6 & 7 Is 24VAC present across transformer terminals C & Y ? Is damper harness securely plugged in at both ends? Secure connections.
15 P art Number 550-110-031/0605 Control Supplement — Standing Pilot Boilers T r oubleshooting continued Is 24VAC present across combination control terminals V 2 & Z ? Is damper harness securely plugged in at both ends? Secure connections.
16 P art Number 550-110-031/0605 EGH-85 & 95 Series 4 and PFG-6 & 7 Series 6 & 7 Parts.
デバイスWeil-McLain EGH-85の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Weil-McLain EGH-85をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWeil-McLain EGH-85の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Weil-McLain EGH-85の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Weil-McLain EGH-85で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Weil-McLain EGH-85を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWeil-McLain EGH-85の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Weil-McLain EGH-85に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWeil-McLain EGH-85デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。