WellsメーカーB506の使用説明書/サービス説明書
ページ先へ移動 of 24
WELLS BLOOMFIELD , LLC 10 Sunnen Dr ., St. Louis, MO 63143 telephone: 314-678-6314 fax: 314-781-2714 www .wells-mfg.com p/n 2M- 303673 R e v . F M 1 6 2 09 0416 r ms OPERA TION MANU AL fo r BU I L T -.
162 303673 OpM anual for Built-In Electric Charbroilers Unless otherwise specified, all commercial cooking equipment manufactured by WELLS BLOOMFIELD, LLC is warranted against defects in ma terials an.
TABLE OF CONTENTS SPECIFICATIONS 1 W A R R A N T Y x i SPECIFICATIONS 1 FEATURES & OPERATING CONTROLS 2 PRECAUTIONS & GENERAL INFORMATION 4 AGENCY LISTING INFORMATION 4 I N S T A L L A T I O N.
FEATURES & OPERATING CONTROLS 2 COMMENT The char-broil er is INFINITE SWITCH C ONTROLLED. Power is applied to the heating elements based o n the control knob position and the amount of energy used. Light will glow when the infinite swit ch is in any position other that OFF.
FEATURES & OPERATING CONTROLS (continued) 3 Fig. 1 Built-In Electric Charbroiler Fig. 2 Wellsloks 162 303673 OpM anual for Built-In Electric Charbroilers.
PRECAUTIONS AND GENERAL INFORMATION 4 Broilers are intended for use to cook fo od products for human consumption. No other us e is recommended or auth orized by the manufacturer or its agents. Broilers are intended for use in commercial establi shments, where all users are familiar with the applianc e limitations, use and associated hazards.
INSTALLATION NOTE: DO NOT discard the carton or other packing materials until you have inspected the appliance for hidden damage and tested it for proper operation. Refer to SHIPPING DAMAGE CLAIM PROCEDURE on the inside front cover of this manual. IMPORTANT: This is a GENERAL GUIDE.
WARNING: Risk of personal injury Installation procedures mu st be performed by a qualified technician with full knowledge of all applicable electrical codes. Failure can result in personal injury and property damage. CAUTION: Electrical Shock Hazard The broiler must be electrically grounded.
OPERATION 7 PREPARE THE CHAR-B ROILER FOR USE When using the broiler for the first time, wipe the entire unit with a clean damp cloth or sponge and mild detergent. Rinse thoroughly clean water. Dry with a soft clean cloth. Remove the GRATE and raise the ELEMENT ASSEMBLY.
OPERATION (continued) CAUTION: Hot Surf ace Exposed surfaces can be hot to the touch and may cause burns. IMPORTANT: DO NOT POUR WATER OVER ELEMENTS TO REFILL PAN. DO NOT splash or pour water onto controls, control panels or wiring. 8 TEMPERATURE CONTROLS Each section of the broiler is equi pped with an individu al temperature control.
OPERATION (continued) 9 BROILER CHART RECOMMENDED COOKING TI MES AND DIAL SETTINGS PRODUCT Condition THICKNESS COOKING SETTING DIAL TIME Minutes Total BEEF Frozen 1/2” Rare 8 4 - 6 “ 1/2” Medium.
TROUBLESHOOTING SUGGESTIONS 10 SYMPTON POSSIBLE CAUSE SUGGESTED REMEDY Won’t heat- - no indicator lights Electric disconnect OFF Circuit breaker tripped Check / turn disconnect ON Check / reset circ.
CLEANING INSTRUCTIONS PREPARATION Turn both temperature control knob s OFF. Allow broiler to cool completely. Disconnect broiler from electri c power. FREQUENCY Daily. TOOLS Steel Brush with Scraper Plastic Scouring pad, Soft-Bristled Fiber Brush Mild Detergent, Non-Abrasive Cleanser Clean Soft Cloth / Sponge CLEANING 1.
EXPLODED VIEW: MODEL B406 12 162 303673 OpM anual for Built-In Electric Charbroilers Model: B406 Built-in Electric Charbroiler PL162 IL1731 Rev . A 4/15/09 1 2 3 4 5 6 7 8 9 10 11 12 13 16 17 18 19 20.
PARTS LIST: B406 13 162 303673 OpM anual for Built-In Electric Charbroilers B406 Electric Charbroiler Fig No Part No Qty Description 1 WS-21707 1 BROILER GRATE B40 / B406 2 H6-32728 1 COVER RR ELEM AS.
EXPLODED VIEW: MODEL B446 14 162 303673 OpM anual for Built-In Electric Charbroilers Model: B446 Built-in Electric Charbroiler PL162 IL1732 Rev . A 4/16/09 1 2 3 4 5 6 10 13 14 15 16 17 18 19 20 21 22.
PARTS LIST: MODEL 446 15 162 303673 OpM anual for Built-In Electric Charbroilers B446 Electric Charbroiler Fig No Part No Qty Description 1 2F-30025 1 GRATE BROILER 2 H6-32740 1 COVER RR ELEM ASSY 3 W.
EXPLODED VIEW: MODEL B506 16 162 303673 OpM anual for Built-In Electric Charbroilers Model: B506 Built-in Electric Charbroiler PL162 IL1733 Rev . A 4/16/09 1 2 3 7 8 10 11 12 13 14 15 16 17 18 19 20 2.
PARTS LIST: MODEL B506 17 162 303673 OpM anual for Built-In Electric Charbroilers B506 Electric Charbroiler Fig No Part No Qty Description 1 2F-30025 2 GRATE 2 H6-32740 2 COVER RR ELEMENT 3 WS-57507 2.
18 162 303673 OpM anual for Built-In Electric Charbroilers WIRING DIAGRAM: B406.
WIRING DIAGRAM: B446 19 162 303673 OpM anual for Built-In Electric Charbroilers.
20 162 303673 OpM anual for Built-In Electric Charbroilers WIRING DIAGRAM: B506.
DESCRIPTION PART NO. GREASE PAN, B-446 (1 PER UNIT) B-506 (2 PER UNIT) H6-35593 GREASE PAN, B-406 H6-35594 GRATE, B-446 (1 PER UNIT) B-506 (2 PER UNIT) 2F-30025 GRATE, B-406 WS-21707 BRUSH, BROILER 2P.
WELLS BLOOMFIELD , LLC 10 Sunnen Dr ., St. Louis, MO 63143 telephone: 314-678-6314 fax: 314-781-2714 www .wells-mfg.com.
デバイスWells B506の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Wells B506をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWells B506の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Wells B506の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Wells B506で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Wells B506を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWells B506の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Wells B506に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWells B506デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。