WellsメーカーHDCB3630Gの使用説明書/サービス説明書
ページ先へ移動 of 32
WELLS BLOOMFIELD , LLC 10 Sunnen Dr ., St. Louis, MO 63143 telephone: 314-678-6314 fax: 314-781-2714 www .wellsbloomfield.com OWNERS MANUAL HEA VY DUTY GAS CHARBROILER MODELS: HDCB1230G HDCB2430G HDCB.
Unless otherwise specied, all commercial cooking equipment manufactured by WELLS BLOOMFIELD, LLC is warranted against defects in materials and workmanship for a period of one year from the date of .
M163 2M-306981 Owners Manual for HDCB-Series Gas Char-Broilers M163 2M-306981 Owners Manual for HDCB-Series Gas Char-Broilers T ABLE OF CONTENTS SPECIFICA TIONS 1 Thank Y ou for purchasing this Wells Bloomeld appliance.
FEA TURES & OPERA TING CONTROLS 2 Fig. 1 Heavy Duty Gas Charbroiler - Features & Operating Controls M163 2M-306981 Owners Manual for HDCB-Series Gas Char-Broilers M163 2M-306981 Owners Manual .
This appliance is intended for use in commercial establishments only . This appliance is intended to prepare food for human consumption. No other use is recommended or authorized by the manufacturer or its agents. This appliance must be installed by a technician qualied and certied or licensed to install gas-red equipment.
INST ALLA TION NOTE: DO NOT discard the carton or other packing materials until you have inspected the appliance for hidden damage and tested it for proper operation. Refer to SHIPPING DAMAGE CLAIM PROCEDURE on the inside front cover of this manual. DANGER: HEAL TH HAZARD This appliance must be properly ventilated.
GAS APPLIANCE CODE COMPLIANCE The installation of gas piping from the outlet side of the gas meter or service regulator to the charbroiler must be performed by a technician qualied and certied or licensed to install gas-red equipment. A licensed and qualied technician must perform the initial startup and adjustment of this appliance.
INST ALLA TION (continued) 6 INST ALLING THE GAS GRIDDLE Refer to the nameplate. V erify the fuel type and pressure, which must match the nameplate specications. Connecting the hotplate to the wrong fuel type and/or pressure will compromise the safety and/or performance of the appliance.
INST ALLA TION (continued) 7 SET GAS PRESSURE: Gas pressure regulator is factory set. SET PILOT FLAME: Remove all burner control knobs, then remove the front panel. Remove grates. The pilot adjustments are near the control valve for each set of burners.
OPERA TION GENERAL OPERA TIONAL NOTES Carefully read the description of the charbroiler operation on the specication sheet. Do NOT use this appliance if it has been submerged in water . Call a qualied technician to examine the appliance and to service or replace any component which has been submerged.
W ARNING: FIRE HAZARD NEVER attempt to force or repair a stuck control valve. Contact your Authorized Wells Service Agency for repairs. Forced or improperly repaired valves pose the risk of re and/or explosion. W ARNING: FIRE AND EXPLOSION HAZARD If the pilot light should be extinguished, turn off the gas shut-off valve.
CLEANING INSTRUCTIONS PREP ARA TION T urn both temperature control knobs OFF . Allow broiler to cool completely . Disconnect broiler from electric power . FREQUENCY Daily . TOOLS Steel Brush with scraper Plastic Scouring Pad, Soft-Bristled Fiber Brush Mild Detergent, Non-Abrasive Cleanser Clean Soft Cloth / Sponge CLEANING 1.
PREP ARA TION T urn gas shut-off valve OFF . Allow broiler to cool before cleaning. FREQUENCY As Needed TOOLS Plastic Scouring Pad, Soft-Bristled Fiber Brush Clean Cloth or Sponge Mild Detergent Clean.
TROUBLESHOOTING 12 M163 2M-306981 Owners Manual for HDCB-Series Gas Char-Broilers M163 2M-306981 Owners Manual for HDCB-Series Gas Char-Broilers SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Pilot will not light Gas supply off Check main / unit gas valves Air in lines T urn pilot valve on.
CUST OMER SERVICE DA T A please have this information available if calling for service REST AURANT _____________________________ LOCA TION _____________ INST ALLA TION DA TE ________________________ T.
14 GAS ORIFICE CONVERSION CHART GRAPHIQUE DE CONVERSION - LE CAPUCHON D’ORIFICE M163 2M-306981 Owners Manual for HDCB-Series Gas Char-Broilers M163 2M-306981 Owners Manual for HDCB-Series Gas Char-Broilers CONVERSION CHART - GRIDDLE NA TURAL GAS ELEV A TION LP / PROP ANE - SEA LEVEL - 2000’ KIT NO.
15 EXPLODED VIEW & P ARTS LIST LA VUE EXPLOSEE & LES P ARTIES ENUMERENT HDCB- SERIES HEA VY -DUTY GAS CHAR-BROILER SERVICE COMPONENTS COLLECTION -HDCB GRIL AU GAZ COMPOSANTS DISPONIBLES M163 2.
MANUEL DE L ’UTILISA TEUR 14 GRIL PROFESSIONNEL À GAZ WELLS MODÈLES HDCB1230G HDCB2430G HDCB3630G HDCB4830G Comprend : INST ALLA TION, MODE D’EMPLOI & ENTRETIEN POUR VOTRE SÉCURITÉ Ne pas stocker d’essence ou d’autres liquides inammables au voisinage de cet appareil ou autres appareils ménagers.
T ABLE DES MA TIÈRES 15 FRANÇAIS DESCRIPTION ET A VERTISSEMENTS DE SÛRETÉ 14 SPÉCIFICA TIONS 15 FONCTIONNALITÉS ET COMMANDES 16 PRÉCAUTIONS & RENSEIGNEMENTS D’ORDRE GÉNÉRAL 17 INFORMA T.
FONCTIONNALITÉS ET COMMANDES 16 Fig. 6 Fonctionnalités et commandes du gril professionnel à gaz M163 2M-306981 Owners Manual for HDCB-Series Gas Char-Broilers M163 2M-306981 Owners Manual for HDCB-.
Cet appareil est prévu exclusivement à l’usage des établissements commerciaux. Cet appareil est destiné à la cuisson d’aliments pour la consommation humaine.
L ’INST ALLA TION REMARQUE : NE P AS jeter le carton ni les autres matériaux d’emballage jusqu’à ce que l’appareil ait été inspecté pour la détection de vices cachés et ait subi des tests de fonctionnement satisfaisants.
CONFORMITÉ AU CODE RELA TIF AUX APP AREILS À GAZ L ’installation des tuyauteries du gaz entre le côté sortie du compteur à gaz ou du régulateur de l’alimentation publique et l’appareil doit être effectuée par un technicien qualié et certié ou agréé pour l’installation des appareils à gaz.
L ’INST ALLA TION (a continué) 20 INST ALLA TION DU GRILL À GAZ Consulter la plaque signalétique. Vérier la nature et la pression du combustible, qui doivent correspondre aux spécications indiquées sur la plaque signalétique.
L ’INST ALLA TION (a continué) 21 RÉGLAGE DE PRESSION DU GAZ : Le régulateur de pression du gaz est réglé en usine . RÉGLAGE DE LA VEILLEUSE D’ALLUMAGE : Enlever tous les boutons de commande des brûleurs puis enlever le panneau avant . Les réglages de veilleuse sont proches du robinet de commande de chacun des jeux de brûleurs .
FONCTIONNEMENT COMMENT AIRES D’ORDRE GÉNÉRAL SUR LE FONCTIONNEMENT Lire attentivement la description du fonctionnement du grill sur la notice de spécications.
A VERTISSEMENT : DANGER D’INCENDIE NE JAMAIS tenter de forcer ou de réparer un bouton ou robinet de commande bloqué. Pour toute réparation, contacter le distributeur agréé Wells. Les boutons ou robinets forcés ou mal réparés posent un risque d’incendie et/ou d’explosion .
INSTRUCTIONS POUR LE NETTOY AGE 24 A VERTISSEMENT : DANGER D’INCENDIE Fermer le robinet d’arrêt du gaz avant le nettoyage. A TTENTION : DANGER DE BRÛLURES Laisser complètement refroidir l’appareil avant de le nettoyer . IMPORT ANT : NE P AS renverser ni verser d’eau sur les boutons de commande.
PRÉP ARA TION Fermer le robinet d’arrêt (sur la position OFF/FERMETURE). Laisser refroidir le gril avant de le nettoyer . FRÉQUENCE Selon les besoins USTENSILES T ampon de récurage en plastique,.
CONSEILS POUR LE DÉP ANNAGE 26 M163 2M-306981 Owners Manual for HDCB-Series Gas Char-Broilers M163 2M-306981 Owners Manual for HDCB-Series Gas Char-Broilers SYMPTÔMES CAUSE POSSIBLE SOLUTION CONSEILLÉE La veilleuse ne s’allume pas Alimentation de gaz fermée Vérier les robinets d’arrêt principal/de chaque unité.
DESCRIPTION P ART NO. Pieds, réglables en métal (jeu de 4) 20563 Brosse, Gril 21708 PIÈCES DE RECHANGE ET SERVICE DE RÉP ARA TIONS 27 RENSEIGNEMENTS À FOURNIR AU SERVICE APRÈS-VENTE Il est recom.
WELLS BLOOMFIELD , LLC 10 Sunnen Dr ., St. Louis, MO 63143 telephone: 314-678-6314 fax: 314-781-2714 www .wellsbloomfield.com.
デバイスWells HDCB3630Gの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Wells HDCB3630Gをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWells HDCB3630Gの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Wells HDCB3630Gの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Wells HDCB3630Gで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Wells HDCB3630Gを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWells HDCB3630Gの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Wells HDCB3630Gに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWells HDCB3630Gデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。