AP413 00- 12 Home The at er Po w er Pr ot ection with Pur eFilt er™ T echnology Pow er Cons ole PF60 User Manual Clear Picture Clean Sound.
PureA V Po w er C onsole T able o f C ont ents 1 P age Introduction ......................................................................................... 2 Sa fe ty Precautions ......................................................................
Intr oduction PureA V Po wer C onsole T hank y ou for pur chasing the PureA V P ow er Console PF60 . The Po wer C ons ole is designed t o clean, prot ect, and efficiently distribut e power t o y our v aluable home theat er sy st em.
PureA V Po wer C onsole Sa fe ty Precautions W arning – Grounding and P olarization Th is product must be plugged dir ectly into a gr ounded AC po wer outle t (3-pr ong).
P ackage C ont ents PureA V Po wer C onsole • User Manual • Pur eA V Po wer Cons ole PF60 • R emot e AC Contr ol Cable • R emot e DC Contr ol Cable (1/ 8” mini-plug cable ) • RJ 45 E thern.
PureA V Po wer C onsole P ow er Cons ole F eatur es 5 1. S witched butt on – t urns the pow er on and off t o the Pow er Console ’ s “s wit ched” outlets 2.
P ow er Cons ole F eatur es PureA V Po wer C onsole 14. Coaxial-Cable Line Input / Output – prot ects c oaxial cable line s from danger ous electrical dis turbanc es that can tr av el down y our coaxial c able line s 15.
PureA V Po wer C onsole Hook up and Inst allation St ep 1 ( optional) Mounting your P ow er Cons ole Th e PureA V Pow er Console c an be mounted t o a standar d A V equipment r ack or inside a cabinet equipped with an equipment r ack. A. R emo ve the br acket s and mounting scr ews fr om the box.
Hook up and Inst allation PureA V Po wer C onsole St ep 2 Progr am the Outlet Banks E ach outlet b ank on the r ear panel o f the Pow er Console is pr ogrammable . Using the slide s witche s on the rear panel, y ou can pr ogram the outle ts f or s witched or uns witched, and f or delay or alw ays -on (no dela y ) (Fig.
PureA V Po wer C onsole Hook up and Inst allation E. T rigger Out: T he trigger out function gives y ou the ability t o control an ex t ernal devic e equipped with a r emote trigger such as a r etr actable movie s cr een when the Po wer Cons ole is swit ched on.
Hook up and Inst allation PureA V Po wer C onsole 10 St ep 3 R emote A C Operation T his function allo ws you t o turn your P ower C onsole on and of f via y our pr eamplifier or r eceiver equipped with a s witched A C pow er outlet.
PureA V Po wer C onsole Hook up and Inst allation St ep 4 R emote DC Oper ation T his function allo ws you t o turn your P ower C onsole on and of f via an y c omponent that is equipped with a 3~30V DC output (low- volt age trigger out).
Hook up and Inst allation PureA V Po wer C onsole 12 St ep 5 C onnect Digit al Components t o Digital Filter 1 and Digit al Filter 2 (Bank 01 and Bank 0 2) Th e PureA V Pow er Console PF60 c ontains t wo isolat ed digital filt ers that ar e optimized t o clean and condition the po wer t o all of y our digital c omponent s.
13 PureA V Po wer C onsole Hook up and Inst allation St ep 6 C onnect V ideo Components t o the Video Filter (B ank 03) Th e PureA V Pow er Console PF60 c ontains an is olated video filt er that is optimized t o clean and condition the po wer t o all of y our video c omponent s.
14 Hook up and Inst allation St ep 7 C onnect A udio Components t o Audio Filt er 1 and Audio Filt er 2 (Bank 04 and Bank 05) Th e PureA V Pow er Console PF60 c ontains t wo isolat ed audio filter s that ar e optimized t o clean and condition the po wer t o all of y our audio c omponent s.
15 PureA V Po wer C onsole Hook up and Inst allation St ep 8 C onnect High-C urrent Audio Filt er (Bank 06) T his outlet is specific ally designed to filt er out AC line noise while delivering maximum curr ent to po wer-hungry amplifier s and other high-curr ent audio component s.
16 Hook up and Inst allation St ep 9 C onnect y our P ay -Per- Vie w /Phone Line Y our PureA V Pow er Console c omes equipped with P ay-P er- View / phone-line pr otection with a built -in splitter . These ar e standar d RJ11 phone jack s and ar e labeled “Phone”.
17 PureA V Po wer C onsole Hook up and Inst allation St ep 10 C onnect y our Coaxial-C ables /DSS Lines Y our PureA V Pow er Console c omes with thr ee pairs o f coaxial-c able c onnections t o prot ect your s ys tem fr om danger ous electrical dis turbanc es that can tr av el down y our coaxial-c ables lines.
18 Hook up and Inst allation St ep 11 C onnect y our Broadband E thernet Line Y our PureA V Pow er Console c omes equipped with br oadband Ethernet line pr otection.
19 PureA V Po wer C onsole Oper ation Ce ntral L CD Control P anel Th e PureA V Pow er Console PF60 is equipped with an adv anced L CD Co ntrol P anel. Most functions of the P ower C onsole can be monit ored fr om this display . A. PureFilt er Indicator – indic ates that the multiphase Pur eFilter cir cuitry is functioning pr operly .
20 Oper ation K. Bank S elector But ton – le ts y ou select which outlet bank s y ou w ant to monitor; pr es s the butt on repeat edly to choose either a single b ank (Fig. 5a ) or all banks (Fig. 5b ). L. Dimmer But ton – adjus ts the brightness of the L CD Contr ol Panel; pr ess it r epeatedly t o change the brightness le vel.
PureA V Po wer C onsole Tr oubleshooting 21 P ow er C onsole is not pro viding power • Check to ensur e that the Po wer C onsole is plugged into a pr operly gr ounded AC w all outlet. S ome outlets r equire a w all s witch t o be turned on in or der to deliv er pow er to the outle t.
Tr oubleshooting PureA V Po wer C onsole 22 Ground F ault indicator is lit GROUND • Check to mak e sure that the P ower C onsole is plugged into a gr ounded AC w all outlet . (3-prong AC outle ts only . Do not use 2 – 3-pr ong adapters .) • If the “Gr ound F ault” indic ator is still lit, y ou hav e a gr ound-wiring pr oblem.
PureA V Po wer C onsole 23 Glos sary of P o w er T erms Alternating C urrent (A C): T he current that is commonly flo wing through the electrical outle ts in y our home. It is an electrical curr ent in the form o f a sine w ave that o scillat es up and down continuously .
B elkin C onnect ed E quipment W arr ant y PureA V Po wer C onsole 24 B elkin C orpor ation warr ants t o the original pur chaser o f an y Pur eA V P ow er C onsole for the lif e of the pr oduct, that.
PureA V Po wer C onsole B elkin C onnect ed E quipment W arr ant y r eplacement o f the damaged equipment is cov ered under a manuf acturer’ s w arrant y , or Belkin C orporation de termine s that the connected equipment w as not used under normal oper ating conditions or in ac cor dance with any labels or instructions.
B elkin C onnect ed E quipment W arr ant y PureA V Po wer C onsole a. T he part number o f the Pur eA V Po wer Cons ole. b. T he equipment that w as connect ed to the Pur eA V Po wer Cons ole at the time of the Oc currence . c. T he equipment that w as damaged during the Occurr ence and the ex te nt of the damage.
B elkin Corpor ation 501 We st W alnut Str eet Comp ton • CA • 902 20 • USA T el: 310.89 8. 1100 F ax: 310.898. 1111 B elkin Components , Ltd. Expre ss Business P ark • Shipton Wa y R ushden • NN10 6GL • United Kingdom T el: +44 (0) 193 3 35 2 000 F ax: +44 (0) 1933 31 2 000 belkin.
デバイスBelkin PUREFILTER PF60の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Belkin PUREFILTER PF60をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBelkin PUREFILTER PF60の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Belkin PUREFILTER PF60の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Belkin PUREFILTER PF60で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Belkin PUREFILTER PF60を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBelkin PUREFILTER PF60の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Belkin PUREFILTER PF60に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBelkin PUREFILTER PF60デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。