White Rodgersメーカー1F83-0422 Thermostatの使用説明書/サービス説明書
ページ先へ移動 of 12
1 Blue Univ er sal T her mostat with Automa tic Heat/Cool Changeo v er Option Single Stage, Multi-Stage or Heat Pump Installation and Operating Instructions for Models: F AILURE T O READ AND FOLLO W ALL INSTRUCTIONS CAREFULL Y BEFORE INST ALLING OR OPERA TING THIS CONTROL COULD CA USE PERSONAL INJUR Y AND/OR PROPER TY D AMAGE.
2 INST ALLA TION Thermostat installation and all components of the control system shall conf orm to Class II circuits per the NEC code. WA RNING ! Remove Old Thermostat A standard heat/cool thermostat consists of three basic par ts: 1) The cov er , which may be either a snap-on or hinge type .
3 THERMOST A T Q UICK REFERENCE Se t SYSTEM Heat FA N Auto Menu Room T emperature Setting T emperature System Indicator Fa n Indicator Displa ys the power le vel of the 2 “AA” batter ies: indicates good power le ve l indicates batteries at about half po we r.
4 INST ALLER/CONFIGURA TION MENU T o enter the Configuration Menu, SYSTEM must be set to HEA T , COOL , EMER or AU T O . With ther mostat in Heat, Cool or A uto , in normal operation, press the Menu button f or at least 5 seconds. The display will sho w item #1 in the table belo w .
5 INST ALLER/CONFIGURA TION MENU 1 & 2) Ke ypad Lock out – This menu selection will display “ Lk” and “OFF” (def ault, ke ypad not lock ed out).
6 OPERA TING Y OUR THERMOST A T IMPOR T ANT! Choose the Fan Setting (A uto or On) Set the F AN Switch to A uto or On. F an Auto is the most commonly selected setting and runs the f an only when the heating or cooling system is on. F an On r uns the f an continuously f or increased air circulation or to allow additional air cleaning.
7 Set Current Time and Date 1) Press MENU and then TIME button once. The display will show the hour only . 2) Press and hold either the or key until y ou reach the correct hour and AM/PM designation (AM begins at midnight, PM begins at noon). 3) Press TIME once again.
8 PR OGRAMMING TR OUBLESHOO TING Comfort Alert Codes The Comf or t Aler t diagnostics product monitors the air conditioning outdoor systems with single phase Copeland Scroll compressors. Abnormal system and electr ical conditions are indicated by flashing ALER T codes on the yello w LED on the Comf or t Aler t module.
9 TR OUBLESHOO TING Reset Operation Note: When thermostat is reset, installer configuration menu settings and programming will reset to f actor y settings.
10 NO TES.
11 NO TES.
www .white-rodger s.com www .emersonc limate.com HOMEO WNER HELP LINE: 1-800-284-2925 White-Rodgers is a business of Emerson Electric Co. The Emerson logo is a trademark and ser vice mark of Emerson Electric Co.
デバイスWhite Rodgers 1F83-0422 Thermostatの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
White Rodgers 1F83-0422 Thermostatをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWhite Rodgers 1F83-0422 Thermostatの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。White Rodgers 1F83-0422 Thermostatの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。White Rodgers 1F83-0422 Thermostatで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
White Rodgers 1F83-0422 Thermostatを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWhite Rodgers 1F83-0422 Thermostatの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、White Rodgers 1F83-0422 Thermostatに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWhite Rodgers 1F83-0422 Thermostatデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。