Blue Univ er sal T her mostat with Automa tic Heat/Cool Changeo v er Option Model Programming Choices 1F95-0671 7 Day 5/1/1 Day Non-Programmab le www .
2 Remove Old Thermostat Bef ore removing wires from old thermostat, mar k wires f or terminal identifi cation so the proper connections will be made to the new thermostat. Installing New Thermostat 1. Pull the thermostat body off the ther mostat base.
3 WIRING DIA GRAMS Figure 2 – Single Stage or Multi-Stage System (No Heat Pump) with Single T ransf ormer Single Stage 1 (SS1) Multi- Stage 2 (MS2) O Energized Constantly in Cool Mode B Energized Co.
4 Single Stage 3-wire Zone V alve application Blower/Circulator Fan Energized Opens Va l v e (4) Constant 24 V olt (Com- mon) 24 V olt (Hot) Cool System 6 Y W C RC CLASS II TRANSFORMER HOT 24V AC NEUT.
5 Programming and Confi guration Items 1 "System On" indicates when heating or cooling stage is energized. "System On +2" indicates when addi tional stages are on. 2 The word " Hold" is displayed when the thermostat is in the HOLD mode.
6 INST ALLER/CONFIGURA TION MENU Thermostat must be in Heat, Cool or Auto. Press and hold the Menu button for at least 5 seconds. The display will show item #1 in the table below . Press Menu to advance to the next menu item. Press or to change a menu item options.
7 INST ALLER/CONFIGURA TION MENU 21 20 18 MENU dS (On) Off Selects A utomatic Daylight Sa ving Time option 22 21 19 MENU (OFF) K eypad Lock out L, P , Limit Selects one of 3 K eypad Lock out confi gu.
8 INST ALLER/CONFIGURA TION MENU 5, 6 & 7) Cycle Rate Selection – The f actor y def ault setting for Heat and Cool modes, SS1, MS2, is medium cycle (ME). F or Heat Pump , HP1, HP2, the default setting is medium (ME). For Emer (A ux) the default setting is f ast cycle (F A).
9 INST ALLER/CONFIGURA TION MENU 24) Limited Cool Range – This f eature provide a minimum setpoint temperature f or cool. The default setting is 45°F .
10 T o pre vent compressor and/or property damage, if the outdoor temperature is below 50°F , DO NO T operate the cooling system. CAUTION ! Cooling System 1. Press SYSTEM b utton to select Cool. 2. Press to adjust thermostat setting below room tem- perature.
11 PR OGRAMMING Energy Sa ving Factory Pre-Pr ogram The 1F95-0680 thermostats are programmed with the energy saving settings sho wn in the table belo w for all da ys of the week. If this program suits y our needs, simply set the ther mostat clock and press the RunSched b utton.
12 A utomatic Daylight Sa ving Calculation The Real Time Clock will adjust automatically f or da ylight sav- ings time, in the f ollowing manner : Increment one hour at 2 AM on the second Sunda y of March and decrement one hour at 2 AM on the fi rst Sunda y of No- vember .
13 Wired Remote T emperature Sensing One remote temperature sensor can be installed indoor or outdoor and connected to the thermostat by a maximum cable length of 100 meters (300 f eet). T er minals +, S and - on the terminal block allo w connection of the remote sensor .
14 Symptom P ossible Cause Corrective Action No Heat/No Cool/No Fan (common problems) 1. Blown fuse or tripped circuit breaker . 2. Fur nace power s witch to OFF . 3. Fur nace blo wer compar tment door or panel loose or not properly installed. 4. Loose connection to ther mostat or system.
15 NO TES.
www.white-rodgers.com White-Rodgers is a division of Emerson Electric Co. The Emerson logo is a trademark and ser vice mark of Emerson Electric Co. HOMEO WNER HELP LINE: 1-800-284-2925.
デバイスWhite Rodgers 1F95-0671の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
White Rodgers 1F95-0671をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWhite Rodgers 1F95-0671の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。White Rodgers 1F95-0671の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。White Rodgers 1F95-0671で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
White Rodgers 1F95-0671を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWhite Rodgers 1F95-0671の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、White Rodgers 1F95-0671に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWhite Rodgers 1F95-0671デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。