Blue Commercial T her mostat with Automa tic Heat/Cool Changeo v er Option and Damper Control Model Programming Choices 1F95-0680 7 Day 5/1/1 Day Non-Programmab le www .
2 Remove Old Thermostat Bef ore removing wires from old thermostat, mar k wires f or terminal identifi cation so the proper connections will be made to the new thermostat. Installing New Thermostat 1. Pull the thermostat body off the ther mostat base.
3 WIRING DIA GRAMS Figure 1 – Heat Pump Systems Figure 2 – Single Stage or Multi-Stage System (No Heat Pump) with Single T ransformer Heat Pump Connections If you do not have a heat pump system, refer to fi gures 2 & 3. Refer to equipment manufacturers' instructions for speci fi c system wiring information.
4 Programming and Confi guration Items 1 "System On" indicates when heating or cooling stage is energized. "System On +2" indicates when a second stage is energized. 2 The word HOLD is displayed when the thermostat is in the HOLD mode.
5 INST ALLER/CONFIGURA TION MENU Press and hold the Menu button for at least 5 seconds. The display will show item #1 in the table below . Press Menu to ad- vance to the next menu item. Press or to change a menu item options. INST ALLER/CONFIGURA TION MENU MENU REF .
6 INST ALLER/CONFIGURA TION MENU 21 20 18 MENU dS (On) Off Selects A utomatic Daylight Sa ving Time option 22 21 19 MENU (OFF) K eypad Loc kout L, P , Limit Selects one of 3 K eypad Loc kout confi gu.
7 INST ALLER/CONFIGURA TION MENU specify. Heating will start 5 minutes early for every 1° of temperature required to reach setpoint. Example: E On is selected and your heating is pro- grammed to 65° at night and 70° at 7 AM. If the b uilding temperature is 65°, the diff erence between 65° and 70° is 5°.
8 INST ALLER/CONFIGURA TION MENU Record the n umber you select f or future use. Press MENU or RunSched to e xit the menu. The secur ity f eature you select will start. The system button will remain active f or 10 seconds to allow setting Heat, Off , Cool or A uto .
9 T o prevent compressor and/or pr oper ty damage, if the outdoor temperature is below 50°F , DO NO T operate the cooling system. CAUTION ! Cooling System 1. Press SYSTEM button to select COOL. 2. Press to adjust thermostat setting below room tem- perature.
10 PR OGRAMMING Energy Sa ving Factory Pre-Pr ogram The 1F95-0680 thermostats are programmed with the energy saving settings sho wn in the table belo w for all da ys of the week. If this program suits y our needs, simply set the thermostat clock and press the RunSched b utton.
11 A utomatic Daylight Sa ving Calculation The Real Time Clock will adjust automatically f or daylight sa v- ings time, in the f ollowing manner : Increment one hour at 2 AM on the second Sunda y of March and decrement one hour at 2 AM on the fi rst Sunda y of No- vember .
12 Wired Remote T emperature Sensing One remote temperature sensor can be installed indoor or outdoor and connected to the thermostat by a maximum cable length of 100 meters (300 f eet). T er minals +, S and - on the terminal block allo w connection of the remote sensor .
13 13 Symptom P ossible Cause Corrective Action No Heat/No Cool/No Fan (common problems) 1. Blown fuse or tripped circuit breaker . 2. Fur nace power s witch to OFF . 3. Fur nace blower compartment door or panel loose or not properly installed. 4. Loose connection to ther mostat or system.
14 NO TES.
15 NO TES.
www.white-rodgers.com St. Louis, Missouri Markham, Ontario White-Rodgers is a division of Emerson Electric Co. The Emerson logo is a trademark and ser vice mark of Emerson Electric Co.
デバイスWhite Rodgers 1F95-0680の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
White Rodgers 1F95-0680をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWhite Rodgers 1F95-0680の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。White Rodgers 1F95-0680の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。White Rodgers 1F95-0680で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
White Rodgers 1F95-0680を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWhite Rodgers 1F95-0680の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、White Rodgers 1F95-0680に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWhite Rodgers 1F95-0680デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。