White Rodgersメーカー1F95-1280の使用説明書/サービス説明書
ページ先へ移動 of 16
Model Programming Choices 1F95-1280 7 Day 5/1/1 Day Non-Programmab le Big Blue Commercial Universal T her mostat with Damper or Economizer Control and Automa tic Heat/Cool Changeo v er Option Single Stage, Multi-Stage, Heat Pump Installation and Operating Instructions APPLICA TIONS 1F95-1280 SPECIFICA TIONS Electrical Rating: Batter y P ow er .
Remove Old Thermostat Bef ore removing wires from old thermostat, mar k wires f or terminal identification so the proper connections will be made to the new thermostat. Installing New Thermostat 1. Pull the thermostat body off the ther mostat base. F orcing or pr ying on the thermostat will cause damage to the unit.
WIRING DIA GRAMS Figure 2 – Single Stage or Multi-Stage System (No Heat Pump) with Single T ransformer Figure 3 – Heat Pump Systems Heat Pump Connections If you do not ha ve a heat pump system, ref er to figure 2. Refer to equipment man ufacturers’ instr uctions for specific system wiring information.
Programming and Configuration Items 1 Displa ys and "Keypad Loc kout" when in ke ypad lock out mode. Displa ys and "T emperature Limit" and "Keypad Lock out" when limited range is activ ated and lock ed. Displa ys only "T emperature Limit" when limited range is activated.
INST ALLER/CONFIGURA TION MENU T o enter the menu: Press the Menu touch k ey . Press and hold f or 5 seconds the Installer Config touch ke y . This displays screen ref erence #1 in the table belo w . Screen Reference numbers appear in top right corner of display .
INST ALLER/CONFIGURA TION MENU 1. This control can be configured f or : MS2 – Multi-Stage System - No Heat Pump (2 heat/2 cool) HP1 – Heat Pump with one stage of compressor (2 heat/1 cool) HP2 .
15. Select Daylight Saving Time Calculation – This feature will allow the thermostat to calculate the DST automati- cally and apply it to the Real Time Clock displa y . Default is On. 16 & 17. Select A utomatic Schedule – This feature allo ws programming a “Comfor t T emperature” into all program periods with the Auto Schedule key .
Selecting F A OFF allows the thermostat to calculate an optimal time to bring on additional stages of heat. When the is used to raise the setting abov e the room tem- perature additional heat stages ma y come on v er y quickly or very slowly (up to 30 minutes later) depending on recent system perf or mance.
OPERA TING Y OUR THERMOST A T If at any time during testing your system does not oper ate properly , contact a qualified ser vice person. Fan Operation If your system does not ha v e a G ter minal connection, skip to Heating System. 1. T ur n on power to system.
Example: If you turn up the heat during the mor ning program, it will be automatically lowered later , when the temporary hold period ends. T o cancel the temporar y setting at any time and return to the program, press Run Schedule . If the SYSTEM key is pressed to select AU TO the ther mostat will change to Heat or Cool, whiche ver r an last.
PR OGRAMMING Energy Sa ving Factory Pre-Pr ogram The 1F95-1280 thermostats are programmed with the energy saving settings sho wn in the table belo w for all da ys of the week. If this program suits y our needs, simply set the thermostat clock and press the R UN key .
PR OGRAMMING Cooling Program Day (occupied) Night (unoccupied) Fan Fa n MON 6:00 AM 75°F Auto 10:00 PM 78°F Auto TUE WED THU FRI S AT 6:00 AM 75°F A uto 10:00 PM 78°F Auto SUN 6:00 AM 75°F Auto 1.
PR OGRAMMING Wired Remote T emperature Sensing One remote temperature sensor can be installed indoor or outdoor and connected to the thermostat by a maximum cable length of 100 meters (300 f eet). T erminals +, S and - on the terminal block allo w connection of the remote sensor .
TR OUBLESHOO TING Symptom P ossible Cause Corrective Action No Heat/No Cool/No Fan (common problems) 1. Blown fuse or tripped circuit breaker . 2. Fur nace power s witch to OFF . 3. Fur nace blower compartment door or panel loose or not properly installed.
15 NO TES.
White-Rodgers is a business of Emerson Electric Co. The Emerson logo is a trademark and ser vice mark of Emerson Electric Co. HOMEO WNER HELP LINE: 1-800-284-2925 www .
デバイスWhite Rodgers 1F95-1280の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
White Rodgers 1F95-1280をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWhite Rodgers 1F95-1280の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。White Rodgers 1F95-1280の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。White Rodgers 1F95-1280で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
White Rodgers 1F95-1280を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWhite Rodgers 1F95-1280の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、White Rodgers 1F95-1280に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWhite Rodgers 1F95-1280デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。