CONTENTS Description .............................................................................. 1 Precautions ............................................................................. 1 Specifications ..........................................
2 SPECIFICA TIONS ELECTRICAL DATA Electrical Rating: 2271W Humidistat 0.5A, @ 120V AC, 60Hz. 2272W 2273W De-Humidistat 1.0A, @ 120V AC, 60 Hz. 2274W Pilot Duty 30V AC, 60Hz., 60VA. SELECT THERMOSTAT LOCATION Proper location insures that the humidity control will provide a desired humidity level throughout the home.
3 ATTACHING HUMIDITY CONTROL TO ELECTRICAL BOX 1. With wallplate still attached to humidity control and wires through wallplate, connect leads together; one black to Line, other black to Load and secure with wire nuts. Connect green wire to electrical box ground.
4 Y G W RC RH HEAT COOL HEAT COOL RC RH W Y G ON OFF OFF AUTO THERMOSTAT SYSTEM FAN RELAY COOLING RELAY 24vAC 120vAC TRANSFORMER JUMPER WIRE HEATING SYSTEM WIRE NUTS TYPE 2273/2274 DEHUMIDISTAT DEHUMIDISTAT FIELD-WIRING TYPE 1F90(W) AUX. RELAY AUXILIARY RELAY CONTACTS S.
5 CAUTION DEHUMIDISTAT CONTROL A dehumidistat wired in parallel may be used to maintain the relative humidity level during unoccupied times re- gardless of ambient temperature. By cycling an air conditioning system the relative humidity is maintained to help prevent high humidity levels which are associated with mold and mildew build-up.
TABLE DES MATIÈRES Description ............................................................................... 1 Précautions .............................................................................. 1 Spécifications ...........................
2 SP È CIFICA TIONS FICHE É LECTRIQUE Charges é lectriques : 2271W Humidostat d'humidification : 2272W 0,5 A à 120 V c.a., 60Hz. 2273W Humidostat de d é shumidification: 2274W 1,0 A à 120 V c.a., 60 Hz Charge de veilleuse : 30V c.a., 60Hz., 60VA.
3 MONTAGE DE LA COMMANDE DANS LA BO Î TE DE RACCORDEMENT 1. Pendant que la commande est encore mont é e sur le socle, par lequel passent les fils, ex é cutez ainsi les raccordements:un fil noir sur le secteur, l'autre sur la charge, en prenant soin de les relier à l'aide de marettes.
4 Y G W RC RH HEAT COOL HEAT COOL RC RH W Y G ON OFF OFF AUTO THERMOSTAT SYST È ME RELAIS DU VENT, RELAIS DE CLIM. 24V C.A. 120V C.A. TRANSFORMATEUR CAVALIER SYST È ME DE CHAUF MARETTES COMMANDE DE D É SHUMIDIFICATION 2273/2274 C Â BLAGE SUR PLACE DE LA COMMANDE DE D É SHUMIDIFICATION TYPE 1F90(W) RELAIS AUX.
5 COMMANDE DE D É SHUMIDIFICATION Une commande de d é shumidification c â bl é e en parall è le peut servir à maintenir le taux d'himidit é relative constant pendant les p é riodes d'inoccupation peu importe la temp é rature ambiante.
デバイスWhite Rodgers 2271の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
White Rodgers 2271をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWhite Rodgers 2271の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。White Rodgers 2271の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。White Rodgers 2271で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
White Rodgers 2271を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWhite Rodgers 2271の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、White Rodgers 2271に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWhite Rodgers 2271デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。