INSTALLATION & OPERATION MANUAL FOR Heavy Duty Gas Griddles MODELS MLS AGM24 ML-135236-AGM24 AGM36 ML-135237-AGM36 AGM48 ML-135238-AGM48 AGM60 ML-135239-AGM60 AGM72 ML-135240-AGM72 AGT24 ML-135231-AGT24 AGT36 ML-135232-AGT36 AGT48 ML-135233-AGT48 AGT60 ML-135234-AGT60 AGT72 ML-135235-AGT72 www.
IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL G AS EQUIPM ENT, WHO SHOU LD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED .
- 3 - INSTALLATION, OPERATION AND CARE OF HEAVY DUTY GAS GRIDDLES GENERAL Heavy Duty Gas Griddles are produce d with quality workmanship and mater ials. Proper installation, usa ge and maintena nce of your griddl e will result in many years of satisfa ctory perfo rmance.
- 4 - LOCATION The installa tion locati on must be kept fre e and clear of comb ustibles. Wh en installin g, never enclose the bottom of t he griddle with a raise d curb or other constru ctions that would obstruc t flow of air into or out of the griddle.
GRIDDLES MOUNTED ON STANDS WITH CASTERS Griddles mou nted on s tands with c asters mus t use a flexible con nector (not su pplied) that complies with the Standard for Co nnectors for Mova ble Gas Appliance s ANSI Z21.69•CSA6.16 , and a quick -disconnect device that complies wi th Gas Fuel, ANSI Z21.
GAS PRESSURE REGULATO R INSTALLATION Gas regulator p ressure is preset at 5” Water Column (W .C.) for nat ural gas, and 10 ” W.C. for propane ga s. No further adjustme nt should be required. Install the re gulator as clos e to the griddle on the gas su pply line as possible.
- 7 - OPERATION WARNING : THE GRIDDLE AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, CLEANING OR SERVICING. BEFORE FIRST USE The griddle is ship ped covered with a protective coating. R emove this film only when the griddle pl ate is being cleaned prior to it s first coo king use.
USING THE GRIDDLE To preheat, turn th e burners on about 20-2 5 minutes before cooking. A uniform and sy stematic ap proach to lo ading the gr iddle will pro duce the most consiste nt product re sults. The griddl e plate is steel, but the surface is relative ly soft and can be scor ed or dented by careless use of a sp atula or scraper.
- 9 - CLEANING THE GRIDDLE Empty the gre ase drawer as needed th roughout the day an d regularl y clean at least on ce daily. Clean the grid dle regularly.
- 10 - ADJUSTMENTS LEVELING 1. Place a level on t he griddle. 2. Adjust leg s by turning the bullet feet a t the bott om of each le g. Using plie rs or a crescent wrench, turn th e feet counte r-clockwise to i ncrease height, and clockwise to decrease height u ntil leveling is achiev ed.
- 11 - MAINTENANCE WARNING : THE GRIDDLE AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, CLEANING OR SERVICING THE GRIDDLE. LUBRICATION All valves and therm ostats must be chec ked and lubricated p eriodically. Check with your Service Agency for details.
- 12 - TROUBLESHOOTING PROBLEM POSSIBLE CAUSES Heat does n ot come on when the th ermostat is turned on 1. Proble m with thermostat . (Call for servi ce) 2. Pilot burner not lit. (C all for service) 3. Problem with gas valve (Call for se rvice) Pilot burner will no t light 1.
デバイスWolf AGT24の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Wolf AGT24をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWolf AGT24の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Wolf AGT24の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Wolf AGT24で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Wolf AGT24を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWolf AGT24の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Wolf AGT24に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWolf AGT24デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。