Worth Dataメーカー5000の使用説明書/サービス説明書
ページ先へ移動 of 126
Owner’ s Manual A battery operated Po r t a b l e B a t c h Reader with V oice M essages for PC, M a c , e t c . P or table Data Collector ™ 5000 T riCoder www .
Warning: This equipment generates, uses and can radiate radio frequency e nergy. If not in stalled and used in accordance with the instruction ma nual, it may cause inte rference to radio comm unications.
T a ble of Contents Chapter 1: H ow to Use this Manual ......................................................................................................................................................... 5 Chapter 2: TriCod er Quickstart ........
3 Other Settings .................................................................................................................................................................................. 45 System Tools .......................................
4 Chapter 16: Powering the TriCoder ....................................................................................................................................................... 93 Turning the TriCoder ON and OFF ............................
5 Chapter 1: How to Use this M anual The TriCoder is an extremely versatile bar code reader. It functions as both a portable data co llection device as well as a fixed on -line bar code reader. Although the T riCoder can per form complex d ata collectio n functio ns, it's true value is in its simplicity.
6 Chapter 2: T riCoder Q uic ks tar t As powerful as t he TriCod er is, its basic o peration is quite simple. Man y peo ple can use P rogram #0 or P rogram # 1 to satisfy their data collection needs. This C hapter helps you get started quickly usi ng Program #0 or Program #1.
7 Program #0 Quickstart The default data collection pro gram, Progra m #0, is a simple progra m, repe ated ly pro mpting the o perator for data entr y of the sa me type. This Tr iCoder program works well for a simple inventory where ea ch item is sca nned.
8 Collecting Data The second step involves collectin g data in the T riCoder. T his is a good time to practice scannin g. I f you are not familiar with scanning bar codes , see Appendix B: H ow to scan a bar code for details and su ggestions. If you don‟t intend on using bar co des later, you can just enter the same data from the keypad.
9 Uploading Data Once you have co llected your data in P rogram # 0, uploading that data to the co mputer is the final step. For the tutorial , we assu me that you ha ve succe ssfully established communicatio n betwee n the computer and the T riCoder.
10 Program #1 Quickstart Sample Progra m #1 pro mpts the operator for " Item " and then " Quantity ". What makes this pro gram different from program # 0 (other tha n the additional " Quantity " prompt) is that Sample Pro gram #1 is editable.
11 Reviewing and Ed iting Data During o r after collecting data, it is possible to review and edit the data while it is still in the T riCoder. You can also delete d ata entirely. Data Review Mode is a ha ndy tool – esp ecially if you know y o u‟ve made a mistake a nd want to correct it before you u p load your data.
12 You can use the STATUS key at any ti me during data collection to check t he a mount o f memory you have left as well as the battery levels: mm/dd/yy hh:mm:ss BATTERY: ------ xx% xxxK BYT ES FREE I.
13 Uploading Data Once you have collected your data in P rogram #1, uploading that data to the co mputer is the final step. For the tu torial, we a ssume that you ha ve s uccessfully established co mmunication bet ween the co mputer and the T riCoder.
14 Chapter 3: Non P ortab le Mode NON PORTABL E mode allows t he user to tra nsmit data directl y from the TriCoder to the host co mpu ter i mmediately without savi ng the data in the T riCoder memory. Once data is e ntered via scanning a bar code or using the keypad, it is transmitted i mmedia tel y by the Tr iCoder to the host.
15 If you are usin g Windo ws® 7, Vista, XP , 2 000, ME, or 98 SE and you wish to upload your files directl y into your appli cation th rough the keyboard, you must choos e 2 – PC OR M AC USB HIS KEYBOARD .
16 Chapter 4: Using Inte gr a ted Har dwar e Utilities Full Speed USB Data Upl oa d and P C Serial Interface Testing communication between PC and a T riCod er w ith fast USB interface or serial interface needs spec ial soft ware.
17 The TriCoder now displays: NONPORT ABLE MODE PRESS <F1> TO EXIT and is ready and waitin g for keypad input or scanner inp ut. Scan the TEST LABEL ab ove. You should see the word T EST LABEL (or data you e ntered on the keypad) o n the TriCoder screen AND on your co mputer scre en.
18 Hardwa re Utilities Serial Settings Once the serial port co nfiguration is finished, clic k o n the " Test " b utton. Click o n the test windo w so that a flashing cursor ap pears. Scan the test label or, if you have no scan ner, type 123 on the TriCoder key p ad, then press the T riCoder ENTER ke y.
Chapter 5: Uploading D a ta If you are read y to upload data, w e ass ume you have estab lished correct communication bet w ee n your T riCoder a nd host and have collected so me sample data, preferab ly u sing the De fault Pr ogram #0 or Sa mple Progra m #1 T utorials.
20 Comma Separated Files Another common file for mat is a Comma Separated File . A TriCoder setup to upload in this format uploads data like this: “DATA”,”DAT A”( CR ) “111111”,” 22” .
21 SUFFIX -- _ Scan the bar cod e for “ doub le quote” then scan the bar co de for the “ co mma”. SUFFIX -- “, _ Press the ENTER ke y to complete the cha nge. Press the Right Arro w to go to PROMPT 02. At the prompt scan the “ double quot e” bar code.
22 The T riCoder is not limited to uploading using o nly the three file formats - Carriag e Return delimited , Comma delimited and Flat File - descr ibed above.
23 Serial Upload Windows Serial PC Users The Worth Data Hardware Utilities program has the abilit y to upload the T riCoder via the serial port in add ition to USB suppo rt.
24 Chapter 6 : T riCoder C onnection Interfacing with the compute r is possibly t he most cr itical oper ation. W ithout proper communication between the co m p uter and TriCoder, all that data you co llected for hours and hours rea lly is n‟t d o ing you much good.
25 Serial Interface The TriCoder can operate as a serial interface reader o n a PC. To use the serial interface, you must have software read ing t he serial port directly, or a keyboard e mulation progra m like P ortKey , (allows a serial interface T riCoder to look like it‟s working a s a keyboard wedge).
26 Chapter 7 : Configuring th e T riCoder Once the hardware is co nnected, the next step is to co nfigure the Tr iCoder and test your communication. I f you are using the seria l interface, you should have i nstalled the serial co mmunication soft ware you want to use (see the previous section).
27 a problem. USB HID Keyboar d Interface The T riCoder ca n operate as a USB HI D keyboard on both a PC and a Macintosh. A USB cable and Setup co nfiguration change is all that is needed. To install the T riCoder as a USB keyboard, use a ca ble C22 .
28 TriCoder for USB HID Keyboard uploads. Pressing the 1 ke y repeatedly will cycle throug h the 3 HOST settings. More than one Setup Parameter can be changed b efore you exit the setup. Pressing while in a Setup Parameter will take you back one step in the Setup Mode ; from there choose a new gro up of setting s.
29 Chapter 8 : T riCoder Set up All of the Set up Parameters are changed via the T riCoder keypad using t he Setup Mo de. Yo u can also send your s etup from the Hardware Utilities via USB using the Full Sp eed USB setup or b y a Clone file also sent from the Hardware Utilitie s .
30 Using the Hardw are Utilities to change Setup Par ameters If you are using the FULL SPEED USB interface, you can use the Integ rated Ha rdware Utilitie s progra m to change your setup parameters.
31 TriCoder Setup Para m eters Al l par ame te rs ar e s et by th e T riC od er key pa d by g oin g int o S ET UP (O pti on 5) fr om the Ma in Men u or ope ni ng sc ree n. Wh en you en te r t he Se tup Mo de y ou w ill s ee the Tr iC ode r S etu p s cre en w ith v ari ous op ti ons to ch an ge.
32 Bar Code Setup On the Bar Code Setup screen key in the number that corresponds to the setup par ameters you would like to cha nge. BAR CODE SETUP CODE 3 OF 9 ------------------------- 1 UPC-A EAN 1.
33 UPC-A/EAN- 13 UPC-A/EAN-13 OPTIONS UPC/EAN ALL -------------- ON/ OFF 1 UPC/EAN SUPPLEMENT ON /OFF 2 UPC-A NSC ----------------- ON/ OFF 3 UPC-A CHECK ------------- ON/ OFF 4 EAN-13 1 ST 2 DIGITS -.
34 2 of 5 Code 2 OF 5 CODE OPTIONS INTERLEAVED 2 OF 5 ------- ON /OFF 1 CHECK DIGIT ------------------- ON /OFF 2 TRANSMIT CHECK DIGIT ON /OFF 3 STANDARD 2 OF 5 ------------ ON /OFF 4 2 OF 5 CHECK DIG.
35 Code 93 / Code 11 CODE 93/CODE 11 CODE 93 --------------------------- ON /OFF 1 CODE 93 FULL ASCII ---------- ON /OFF 2 CODE 11 --------------------------- ON /OFF 3 CODE 11 CHECK TRAN ------ 0 /1/2 4 DONE/EXIT -------------------------------- 0 CHANGE SETTING #: _ Code 9 3 is si milar in characte r set to Cod e 39.
36 I/O SETTINGS HOST (Computer Interface) The TriCoder is shipped with the HOST Comp uter Interface set to USB FULL SPEED as the default . I/O SETTINGS HOST ---------------- USB-FULL SPEED 1 TERMINATO.
37 FULL SPEED USB If you are usi ng Win dows and you wish to use th e Hardwar e Uti lities to uploa d data via USB in full sp eed, choos e FULL SPEE D USB fo r the HOS T interf ace. You wi ll als o be abl e to do prog ram up loads/ downl oad s, fi rmwa r e upgra des, voice uploads , and tabl e down loads .
38 Terminator Character I/O SETTINGS HOST ------------- HID KEYBOARD 1 TERMINATOR CHARACTER - CR 2 SINGLE CYCLE UPLOAD OFF 3 BAUD RATE ---------------------- 9600 4 PARITY --------------------------- .
39 Parity I/O SETTINGS HOST ----------------------------- SERIAL 1 TERMINATOR CHARACTER - CR 2 SINGLE CYCLE UPLOAD OFF 3 BAUD RATE ---------------------- 9600 4 PARITY --------------------------- NONE.
40 USB ENUMERATION DELAY I/O SETTINGS HOST ---------------- USB-FULL SPEED 1 TERMINATOR CHARACTER - CR 2 SINGLE CYCLE UPLOAD OFF 3 BAUD RATE ---------------------- 9600 4 PARITY ----------------------.
41 USB ALT OUTPUT I/O SETTINGS HOST ---------------- USB-FULL SPEED 1 TERMINATOR CHARACTER - CR 2 SINGLE CYCLE UPLOAD OFF 3 BAUD RATE ---------------------- 9600 4 PARITY ---------------------------- .
42 SPEAKER OPTIONS SPEAKER OPTIONS BEEP VOLUME ----------------------------- 0-9 1 BEEP TONE ------------------------ 1/2/ 3 /4/5 2 VOICE VOLUME ----- HIGH/ MED /LOW/OFF 3 KEYPAD TONE ----------------.
43 Date & Time Settings DATE & TIME SETTINGS TIME --------------------------- 0907 1 DATE -------------------------- 122309 2 DATE FORMAT -------- US A /EURO 3 YEAR OUTPUT --------- 2 /4 - DIG.
44 LCD Options LCD OPTIONS MASTER BACKGD, COLOR --- 1 1 PROMPT BACKGD, COLOR --- 1 2 PROMPT TEXT COLOR --------- 2 3 DATA BACKGD, COLOR -------- 1 4 DATA TEXT COLOR -------------- E 5 BRIGHTNESS --- L.
45 Other Settin gs OTHER SETTINGS PREAMBLE ------------------------- 1 POSTAMBLE ------------------------ 2 CHARACTERS ----------------------- 3 EOF STRING ------------------------- 4 DONE/EXIT ------.
46 Using the Bar Code ID feature and the Prea mble or Postamble , you can tri m data selectively, trimming characters o nl y o n the bar code type specified.
47 System Tools SYSTEM TOOLS CHARGING FROM USB - YES/ NO 1 PL AY VOICE PROMPT -------- 00 2 LANGUAGE ------------- ENGLISH 3 RESET SETUPS TO DEFAULT 4 RESET PROGRAMS & DATA ----- 5 CLEAR DATA FILE.
48 Chapter 9 : Using the Inte gr ated Har dw are Uti lities The Hard ware Utilities for Windo ws program is a versatile ap plication that gives you the ab ility to: Test communication (Serial and .
49 If you are connected via U SB, you should see TriCoder HCVxxxx i n the Far Left Pane as sho wn below..
50 If you do not have your T riCoder turned on and cabled up correctly, or the USB driver is installed incorrectly, you will see this erro r message: USB T riCoder Not Found You can turn your TriCoder.
51 Uploading from TriCod e r to your C om puter You can upload programs, dat a, voice and cloned setup info rmation to your co mputer from your TriCod er by either the serial p ort or the USB port. Serial Uploading If you ar e uploading your T riCoder from the Serial port, make sure your port settings are correct before you b egin your uploa d.
52 Clone Files 1. Turn the TriCoder On. 2. In the Hardware Utilities , ch oose Clone TriCo der a s the File type, t hen speci fy the name of the file (we reco mmend using the extension .cln for clone files) 3. Click the START butto n in the Ha rdware Utilities .
53 Full Speed USB Upload in g If you ar e uploadin g informat ion from your T riCoder via Full Spee d USB interface, you will be absolutely a mazed at ho w ea sy it i s! The Hardware Utilities ta kes care of it all; your TriCoder just has to be turned on.
54 Type in the na me of the file you want to save, or use t he default na me as shown and click save. T hat's it! You don 't ha ve to do anything on the TriCoder ! Program Files 1. Again, make sure you are connected with a C22 USB cable and that your TriCod er is tur ned on and is on the openi ng screen.
55 Do wn lo adi ng f rom t he co mp ut er to y our T ri Cod er You can download saved files on your computer back into your TriCoder using t he TriCoder Manager in the Hard ware Utilities in either ser ial or high -speed US B mode. T he files must be valid TriCod er pro grams, tables or clone files.
56 The Ha rdware Utilities will let you know when your trans mission is finished. Full Speed USB Downloads If you are do wnloading from your co mputer to your TriCoder via the Full Spee d USB interfac.
57 Chapter 10 : Cr ea ting a Custom Pr ogr am You can create a pro gram in the TriCoder to prompt the op erator for anything. You can t ell the oper ator what to do next, not i fy the m of errors, date and time sta mp the data or review and edit previous d ata.
58 Program Name Press the number of the pro gram you wish to create or edit; 1 , 2 , or 3 . For this example we w ill key in 1 . T he TriCoder then displays: PROGRAM #1 PROGRAM #1 NAME ---------------.
59 Programming To ed it Program #1 press the 2 key. T his will enter you i nto the editing section and sho w you pr ogramming pro mpts and allow you to edit each section of the pro mpt on one scr een. The te xt belo w i s an exa mple of what you s ee o n the T riCoder screen when crea ting a program.
60 Entry Type The first li ne on the progra m screen is the ENTRY TYPE prompt. This prompt deter mines what type of data is entered for this statement. This is the most important pr ompt as it determines exac tly what happen s at this step in the p rogram.
61 Go to state m ent 34 if a 5 is keyed/scanned Go to state m ent 02 if anything else is keyed/ scanned The ST MT TO BRANCH field would look like this: ENTRY TYPE --------------------------- B PROMPT TEXT: TRANSACTION? STATEMENT TO BRANCH R18534*02_ Question A question statement creates a program pro mpt that the us er answers YES o r NO to .
62 The Time Sta mp state ment type records only the time in formation to memory in the HHMM format. Just as with t he Date and Time Stamp statement, using DIS in the DATA ID field will dis play the time information o n the T riCoder screen when the statement is executed.
63 None The None statement entry type is used as a “dummy” statement, recording no data an d transmitting only the Upload prefix and suffix . It is typically used as a destinatio n for a branch statement , allowing you to rec ord wh at a ction the operator took w it hout reco rding any data.
64 ! (space) UF (space) myfile.fmtCRLF data1 CRLF data2 CRLF data3 CR a nd LF are scanned from the F ull ASCII Menu and the filename must e nd with " .fmt". No CRLF is r equired after the last data item. The Tr iCoder will do it for you. Here is a progra m example using ref er -backs Stmnt # Type Prompt Min.
65 Then the user would see the P rompt SCAN ITEM NO: and then the “Ite m Descriptio n”, “Price” and “Quantity On Hand” from the Table as sho wn b elow: SCAN ITEM NO: 69 -1894ES-1 Honey w ell VisionPRO TH8000 The rmostat $125.
66 for the prompt is 123 4, then the next time the PROMPT text is displayed, it w o uld display as follo ws : ENTER ITEM NO. 1234 _ To accept 123 4 as the actual data (instead of enterin g new d ata), simply press the ENT ER key on the TriCoder.
67 DATA ID: _ The DATA ID field has 6 different functions, d epending on what is entered at the pr ompt: Data Identifiers UPC/EAN Chec k Digit verification Table Access Display Date/Time Prevent Duplicate Entry Compare Data 1.
68 Table Lookup: For table lo okup functions the TriCoder can display additional fields associated with the „key‟ field displa ying up to 3 additional fields from t hat record in the tab le.
69 DATA LENGTH MAX: 13_ To clear the DATE LENGTH M AX : and enter a new value, press CLEAR on the Tr iCoder keypad and enter the ne w value. The DATE LEN GTH MAX is i mportant when usin g the Xtra State ment. See t he section on the XTR A ST ATEMENT for more information.
70 you have a progra m that prompts for (1 )BLDG., then (2)AISLE, then (3)ITE M, then (4)QUANTIT Y, w it h a loop that goes b ack to IT EM after QUANT ITY. T o b reak o ut of the loop at ITEM and go back to B LDG, use 01 in the NO/END STMT for ITE M. To break out of t he loop at QUANTITY and go to AISLE, use 02 in the NO/END STMT for QUANTITY.
71 As an example, let‟s say you wanted to attach an aisle nu mber as a prefix to every item nu mber you e ntered. Assuming the aisle number is state ment # 02, entering }02 in the Upload Prefix of the ite m number state ment would attach t he aisle number to ever y item number.
72 For example, if statement #0 1 has a Maximu m Data Len gth of 10 and you sca n the nu mber 12345, the follo wing Uploa d Prefix for statement #1 w o uld produce d ata of 0000012345.
73 Finishing and che c king your pr ogram When you have finished entering your progra m, press the ke y to have the Tr iCoder check your pro gram for errors. If you have refer enced a statement n umber that doesn‟t exist or has n‟t been defined prop erly, you will see the message: INVALID STMT .
74 Reviewing and M odifying programs You can rev iew or modify a program at a ny time. If you have data collected for that program, the o nly portions you can r evie w or modify ar e the Prefix and Suffix . This is a safeguard to make sure you do not d amage data alread y collected before it is upload ed.
75 Chapter 11 : Cr ea ting T riCoder Pr ogr ams on y our Windows PC You can also create custo m Tri Coder programs on your PC and do wnload the m to the TriCoder using our Virtual TriCoder in the Integrated H ardware Utilities . The program is configured to do wnload the files through a USB port o r a Serial port.
76 3. S ele ct the T riC od er Tab on th e lef t of th e S cr een 4. S ele ct Vi rtu al Tr iCo der on t he Tri Cod er Ma nag er Men u 5. Pr es s t he St art V irt ual T riC ode r b utt on an d f oll o.
77 6. You will then see the follo wing screen(s) for the Virtual T riCoder: From this screen you can start to create a new TriCoder Progra m. By d efault the View Table (P rogram Grid) is activated and will also appea r with the Virtual TriCoder screen.
78 Chapter 12 : V oi ce Messa g es The TriCod er's e xclusive use of voice prompts allows you to overco me pr oblems such as literac y, lan guage a nd li ghting. With p roper planning, voice pro mpting can make data collection signi ficantly faster and simpler.
79 Recording and Playba c k of Voice Messages Voice Messages are r ecorded only in the Hardware Utilit ies Pro gram. You can record, manage, and sor t voice files using the Voice option in the TriCoder Manager. Belo w is a screen shot of this process.
80 Default Voice Mes sages Th e TriC od er com es f rom th e f ac to ry w it h s om e v oi ce prom pt s a nd e rro r m ess ag es pr e-re co rded . You ca n chan ge an y of the se me ss age s bu t k eep in mi nd th at th e e rr or con dit ion s tha t the vo ic e e rro r m es sag es ar e l ink ed t o a re fix ed .
81 Chapter 13 : T ab les The T riCoder allows y o u to do wnload a lookup table for verifying data and/or d isplaying data from a tab le to complement the d ata collection pr ocess. In addition, you can use tables to updat e things like prices descr iptions and other data that you ha ve stored in a file but may be different in the field.
82 08000000000EX A M PLE2 11111111 22 xxxxxx 33333 xxx 44444444 Ctrl Z (ASCII 26) ( use if a DO S file ) EXAMPLE2 above would accept a scan or entry of 22 when EX A M PLE1 would not. Preventing duplicate entry o f data Sometimes you might want to make sure that an ite m in your table i s not scanned o r entered t w ice.
83 Chapter 14 : T r oublesh oo ting Display and Error Messages The follo wing is an alphabetical list o f all mess a ges t he T riCoder can displa y. Some desc ribe an er ror state; o thers are simply instruction.
84 FATAL ENTRY T YPE CANNOT CONTINUE CYC LE POWER An invalid E ntry Typ e has been detected in your program. C ycle powe r & see if it clears the error.
85 TABLE FORM AT ERROR PRESS ANY KEY_ The table heade r is in an invali d format or EOF Ctrl Z (ASCII 2 6) is missing. Check table file for format errors. Try again. TABLE NOT FOUND HIT ANY KEY_ A table refer enced in a data coll ection program does not exist.
86 General Troubleshooti ng If you want to what the settings in th e T riCoder are, you can e nter Setup M ode , key i n the number tha t correspo nds to the Para m eter (s) in which you are interested, and then read the display settings re ferring to the TriCoder Manua l for an explanatio n of the options.
87 Poor read rates … o Try read ing the bar code below as an example o f a known “good” b ar code. T his bar co de is a Code 39 b ar code and is readable b y th e T riCoder set to its default settings. o Make s ure your bar codes have clearly d efined dark bar s and clean white spaces.
88 USB troubleshooting (for Wi ndo ws Users) The bulk of USB pro blems are due to d river(s) installations not being co m p leted and the data transfer(s) won't work.
89 Serial mode troub l eshooting Th e f ol low in g p ro blem s pe rtai n m os tly t o T riC od er‟ s s etu p in se ria l m od e. Using the 5 volt power adapter, the TriCoder does not beep when turn.
90 Program troubleshooting The following exa mples have to do with programming the TriCoder . When editing a program, all I can see are the upload prefixes and suffixes… If there is a data file currentl y in the TriCoder , you cannot edit any par t of the programs e xcept for the Upload Pre fix or Upload Suffix.
91 Planning for success … Before you set o ut on your first big inventor y or other d ata collection eve nt, there are a few t hings you can do to better yo ur chances for succe ss. Planni ng and testing before the b ig d ay ca n help you a void headac hes as well as numerous calls to tech s upport.
92 Chapter 15 : F ail-safe R e-initializa tion Pr ocedur e Here is a fail-safe way to re-initialize the TriCod er and set it b ack to the factory defa ults: (also useful for deleting a data file and programs no longer needed) .
Chapter 16 : P owering the T riCoder The T riCoder can be p owered by the internal Li -ion batter y or by the Wo rth Data 5 -volt power adapter included with the unit. T he TriCoder also has a progra mmable auto matic shutoff i ntended to conserve po wer.
94 Battery Power For po rtable use, there is a rep laceable, built -in 1 950mAh N P-120 Li-ion batter y used by t he Tr iCoder. This batter y provides t he mai n power for the scanner, display and all electrical circ uitry.
95 Chapter 17 : F irmwar e Upg r ades Occasionally it will be necessary for so me users to update the T riCoder's firm ware to fix a bug or take advantage o f new capab ilities added to the TriCoder. T he TriCoder uses a Flash EPROM and can be updated b y do wnloading a file using the Hard ware Utilit ies .
96 Select TriCod er and then Press Next: Select the COM por t you are using if you are co nnecting by Serial Cable or Select USB is you are co nnecting by USB.
97 Browse your co mputer to find the fir mware file you want to use. T he la test fir mware can always be downloaded from o ur w eb site ( www.barcodehq.com/do wnloads.html ). W hen you have sel ected the correct file press the Next butto n. Con nect the T riCoder to the computer using a serial ca ble or USB cable and press the Next butto n.
98 Failsafe Firmw a re Update If your TriCoder firmware update is i nterrupted, you ma y end up with a T riCoder that will not fu nction proper ly. If yo u have a 5 000 version T riCoder, you ca n perfor m the failsafe update by either USB or serial port.
99 Appendix A : How to sc a n a bar code The TriCod er can be used with a variety of la ser scanners. W hich o ne you choose is dependent upon your ap plication and the qu ality and density of your bar codes. This sec tion will include infor mation on different laser scanners as well as how to use each one.
100 Appendix B: Laser S c anner Opt io ns The laser scanner is t y p ically the easiest sca nner to u se, requiring less operato r training. A par ticularly d esirable featur e o f the laser scanner is t hat upon triggeri ng the beam, the laser sca ns the bar code multiple times (36 -100 scans per second) until it has a goo d read.
101 Appendix C: Ca ble Pin-outs Below are the pin -outs for o ur ca bles. All cables showing a Worth Data part number ( C xx) ar e a vailable for purchase.
102 I/O Connector Pin-outs I/O Connector pin-o uts are: Pin Function 1 Ground 2 Ground 3 Laser DLE 4 USB D+ 5 Laser EN 6 USB D- 7 Laser Data 8 USB Vbus 9 Laser SOS 10 - 11 5VDC Input 12 5VDC Input 13 .
103 Appendix D: Opt io nal F ea tur es The follo wing ar e the features availab le for the TriCoder: Item # Description F10 5V/110V Pow er Supply F11 5V/220V Europe an d South American Power Supply F1.
104 Appendix E: USB Driver Installa tion R ecov ery The USB TriCoder uses two sep arate USB “drivers”: T he HID driver provided with W indows and t he Full Speed transfer driver provided with the TriCod er. Which driver is active dep ends on the op erating m o de of the TriCod er.
105 9. Select "Search for a suitable driver for my d evice ( recommended) ." and click "Next" 10. Select "Specify a location" an d click "Next" 11. Browse to the Worth Data Utilities CD -ROM o f the folder where you unpacked files d ownloaded from www.
106 Resolving incomp le te, abort ed or incorrect HID driver install a tion This dr iver is pr ovided with Windo ws . Most recent versions o f Windows include necessary file s in t he installed Windo ws folder so driver installation is eas y if not automatic.
107 Appendix F: Specifica tions f or Code 39 Code 39 (or Cod e 3 of 9 ) is the de facto standard of non -retail American i ndustry. It is widely used in the a utomotive industry ( AIAG specifications) as well as in govern ment and military applications ( LOGMARS spec ifications ).
108 Code 39 Advanced Features a nd Functions Mod 43 Check Character Standard Code 39 can be printed with a " M od 43 Check C haracter " . T his Mod 4 3 check character cannot be used with Full ASC II Code 39 .
109 Full ASCII Extension to Code 39 " Full-ASCII Code 39 " expands t he Code 39 character set to include all 128 ASCII c haracters. Symbols 0 -9, A-Z and p unctuation characters .
110 Function/Control Key Support in HID Keyboard Mode The TriCoder , when in HID Keyboard Mo de, can transmit Function, Contr ol , Alt and Shi ft Keys for use with software pr ograms that use t hese keys for menus or commands.
111 Th e SHI FT, CTR L, & AL T (Com ma nd an d Op ti on for MAC ) k eys m us t us e ON (ke y pr es sed ) an d OF F (k ey re le ase d) ba r co des to pro per ly em ul ate k eyb oar d fu nct io ns . Fo r ex am ple , to en cod e a ba r cod e se que nc e f or Ct rl-C , y ou w ou ld cr eat e a b ar cod e of C tr l O N, C, an d C tr l OFF .
112 Function/Control Key Support with PortKey The TriCoder in RS-232 ASCI I mode using PortKe y can emulate the special keys on the P C keyboard. P ortKey expects the " extend ed key code " convention o utlined in the B ASIC manuals and most co mpiler manuals.
113 A c cumulate Mode Accumulate Mode is an option allowing the TriCoder to accumulate multiple bar codes in its buffer, then transmit the m to the computer as if they had been a single bar cod e. This is useful for entering quantitie s and other variable data.
114 Appendix G: Code 128 Sp ecif ica tions Code 128 is a very p owerful bar co de, combining an extensive char acter set and variable length with compactness and e rror che cking. The character set contains all 128 ASCII characters with each character made up of three b ars an d three spaces.
115 Appendix H: Inter lea ved 2 of 5 Code Interleaved 2 of 5 Code is a numeric -only, e ven-number- of -digits bar cod e. It is widely used in warehouse and ind ustrial app lications. A co m b ination of five ele m e nts, t wo wide a nd three narro w repr esent each character .
116 Appendix I: UPC Sp ecifications UPC s ymbols are fo und on almost all grocer y products and many other retail ite ms. T he UPC code most people are familiar with (UP C-A) is a fixed -length (12 digits) numeric o nly code, with the fir st digit controlled by UPC co ding assignments and the last digit a c hecksum.
117 option of transmitting in the I SBN format. ISBN 0- 553 - 37062 ISBN specifications are available fro m: American National St andards Institute Customer Serv ice 11 West 42 nd St.
1 18 UPC-E Checksum Calculation Use the sample data of 12 3456 to demonstrate the UPC -E c hecksum calculatio n: The 6 digit UP C-E code is converted to a 10-digit cod e, using an expansion scheme bas.
119 Appendix J: Coda bar Specifica tions Cod abar is wid ely used in li braries , blood b anks, th e cotton indust r y an d trans porta tion indu stries. I ts' chara cter set con sists of numbers 0 th rough 9 , an d punctu ation charact ers + . - / : and $ .
120 Appendix K: MSI/Pless ey Sp ecif ica tions Pl ess ey is a var ia ble len gth nu mer ic onl y bar co de. MSI Ba r Co de is a v ari abl e leng th , nu me ric -on ly co de w ith an au tom at ica lly ap pen de d Mo du lus 10 ch eck digi t . MSI is s ome tim es ca ll ed Mod ifi ed Pl ess ey C ode .
121 Appendix L: Code 93 Spe cif ica tions Code 93 is variable length, conti nuous, bi -directional, compact cod e. Code 93 is an alp hanumeric bar code which consi sts o f 43 data characters ( 0-9 , A-Z , $/+%.- and Space ), 4 control characters , and a unique start/stop character .
122 Appendix M: A SC II Cod e Equivalent T ab le The 128 ASCII co des and th eir 3 d igit deci mal eq uivale nts are d etailed in the belo w tab le. T he RS232 Mod els use the ASCII; the keyboard wedge models have some of the unprintable ASCII characters rea ssigned to specific keys, (i.
123 Appendix N: RS -4 22 Using the T riCoder with an RS -422 boar d instead of a stand ard RS-23 2 serial port allows multiple TriCod ers to be multi -drop ped off of a sin gle RS -422 port at a d istance up to 4000 fee t. Multiple TriCoder s can then be polled periodically while they are collecting data.
Max Chs 01-99 T riCoder Coding Form Program Name: Date: Statement No. Entry Type D-Data Q-Quest T-Time Y-Date S-Both B-Brnch X- Xtra Prompt Text Data ID Unique 3 Chars or table ID or Time Display Data Type:D N A, or Blank Min Chs 00-99 (2-Chs) Input Device: K, W or Blank Next Stmt Num.
NUL DLE(f10) SP 0 @ P ` p SOH(f1) DC1(Del) ! 1 A Q a q STX(f2) DC2(Ins) “ 2 B R b r ETX(f3) DC3( ) # 3 C S c s EOT(f4) DC4( ) $ 4 D T d t ENQ(f5) NAK( ) % 5 E U e u ACK(f6) SYN( ) & 6 F V f v BE.
デバイスWorth Data 5000の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Worth Data 5000をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWorth Data 5000の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Worth Data 5000の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Worth Data 5000で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Worth Data 5000を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWorth Data 5000の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Worth Data 5000に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWorth Data 5000デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。