TM TM Freedom HF Inverter/Char gers Installation Guide Product image sho wn may vary from actual product. See featur es for comparisons. Model Numbers 806-1020, 806-1055, 806-1055-02 806-1840, 806-1840-01, 806-1840-02 Freedom HF Install Guide.
Freedom HF Install Guide.book Page 2 Thursday, November 2 4, 2011 11:06 AM.
975-0395-01-01 i InstallationT rademarks Xantrex and Smart choice for power ar e trademarks of Schneider Electric, registered in the United States and other countries. Other trademarks, registered trademarks, and product names are the prop erty of their respe ctive owners and are used herein for identif ication purposes only .
ii F reedom HF Installation Guide About This Guide Purpose The purpose of this Instal lation Guide is to provide explanations and procedures for installing and configuring a Freedom HF Inverter/Char ger for Recreational, Fleet V ehicl e, or Marine installations.
975-0395-01-01 iii Related Inform ation Y ou can find more information about Xa ntrex T echnology Inc. as well as its products and serv ices at www .xantrex.com . ST A TEMENT OF HAZA RD Contains state ments of avoi dance or strict compliance. Failure to follow these instructio ns can damage the unit and/or damage other equipment.
iv F reedom HF Installation Guide Important Safety Instructions IMPOR T ANT : R EAD AND SAVE THIS I NSTALLATION G UIDE FOR FUTURE REFERENCE . This chapter contains important safe ty instructions for the Freedom HF Inverter/Char ger (Freedom HF).
975-0395-01-01 v NO TES: 1. Follow these instructions a nd those published by the battery manufacturer and the manufacturer of any equipment you intend to use in the vicinity of the battery . Re view cautionary markings on these products and on the engine.
vi F reedom HF Installation Guide Precautions W hen W orking With Batteries NO TES: 1. Mount and place the Freedom HF Inverter/Charger unit away from batteries in a well ventilated compart ment. 2. Always have someone within range of your voice or close enough to come to your aid when you wo rk near a lead-acid battery .
975-0395-01-01 vii Precautions W hen Preparing to Charge NO TES: • Study and follow all of the battery manufacturer's specific precautions, such as removing or not removing cell caps while charging, wh ether equalization is acceptable for your battery , and recommended rates of charge.
viii F reedom HF Installation G uide Precautions for Using Rechargeable Appliances Regulatory The Freedom HF Inverte r/Cha r ger is certified to appropriate US and Canadian standards. For more inform ation see “Regulatory Approvals” on page 37. The Freedom HF Inverte r/Cha r ger is intended to be used for mobile or commercial applic at ions .
975-0395-01-01 ix FCC Information to the User This equipment has been tested and f ound to comply with the limits for a Class B digital device, pur suant t o part 15 of the FCC Rules. T hese limits are designed to provide reasonable pr otection against ha rmful interference in a residential insta llation.
Freedom HF Install Guide.book Page x Thursday, November 2 4, 2011 11:06 AM.
Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv Materials List . . . . . . . . . . . . . . . . .
Freedom HF Install Guide.book Page xi i Thursday, November 24, 2011 11:06 AM.
975-0395-01-01 1 This guide for use by qua lified installers only. Materials List Y our Freedom HF Inverter/Charger package includes the items listed below . • one Freedom HF unit, • one set of owner ’ s and installa tion guides and a mounting template, • one display panel with 7-inch (0.
2 F reedom HF Installation Guide Safety Instructions • Before you begin the installation, review the “Important Safety Instructions” on page iv, and read this entire section so you can plan your installation from beginning to end. • Disconnect all AC and DC power sour ces to prevent accidental shock.
975-0395-01-01 3 This guide for use by qua lified installers only. Installation T ools and Materials Y ou will need the following to install the Freedom HF: ❐ W ire stripper ❐ Mounting screws or bolts ❐ #2 Phillips screwdriver ❐ 3.
4 F reedom HF Installation Guide High Level Overview of Installation Steps Installing the Freedom HF in cludes the following steps. 1. Ensure that AC and DC power are both OFF . 2. Mount the inverter securely and pe rmanently in one of the acceptable orientations.
975-0395-01-01 5 This guide for use by qua lified installers only. Basic Installation Procedures Xantrex recommends th at you have your installation performed by a qualified technician or elec trician. This section provides sample installatio n information as a guide for your installation.
6 F reedom HF Installation Guide Basic Installation Procedures Step 1: Designing the Installation Most Freedom HF instal lations share common components, and some of these are briefly described below . Figure 1 shows some components and their relationship to each other in a typical recreational vehicle or fleet vehicle installation.
975-0395-01-01 7 Basic Installation Procedures This guide for use by qua lified installers only. A C shore power A source of 120 volts, 60Hz sine wave alternating current is needed to provide energy to char ge batteries and pass power through to AC loads.
8 F reedom HF Installation Guide Basic Installation Procedures A C Distribution P anels Most systems incorporate distribution centers both ahead of the Freedom HF (the AC source panel) and betwee n the Freedom HF and the loads (the AC load panel).
975-0395-01-01 9 Basic Installation Procedures This guide for use by qua lified installers only. A C Output Neutral Bonding The neutral conductor of the Freedom HF’ s AC output circuit (i.e., AC Output Neutral) is au tomatically connected to th e safety ground during inverter operation.
10 F reedom HF Installation Guide Basic Installation Procedures DC Disconnects and Over -Current Devices The DC circuit from the battery to the Freedom HF must be equipped with a disconnect and over-c urrent device. This usuall y consists of a circuit breaker , a “fused-disconnect,” or a se parate fuse and DC disconnect.
975-0395-01-01 11 Basic Installation Procedures This guide for use by qua lified installers only. Step 2: Choosing a Location for the Unit The Freedom HF should only be instal led in locations that meet the following requirements: ❐ Dry . Do not allow water or other flui ds to drip or splash on the Freedom HF.
12 F reedom HF Installation Guide Basic Installation Procedures Step 3: Mounting the Unit T o mount the Fr eedom HF: 1. Remove the Freedom HF from its sh ipping container , verify that all components are pres ent , an d record relevant product information on “Information About Y our System” in the Owner ’ s Guide.
975-0395-01-01 13 Basic Installation Procedures This guide for use by qua lified installers only. Connecting the Equipment Ground The Freedom HF has a ground stud on the side of the unit as shown in Figure 3. Follow the guidelines in “Grounding Locations” to connect the inverter ’ s chassis to the ground.
14 F reedom HF Installation Guide Basic Installation Procedures Step 4: Connecting the A C Input W ires General A C Wiring Considerations AC Wiring Connectors Where applicable, connect AC wires with crimp-on splice connectors.
975-0395-01-01 15 Basic Installation Procedures This guide for use by qua lified installers only. The AC input terminal is located on th e front panel and is labeled pro perly as AC IN or AC I N P U T . Depending on the model, you can have three types of wire terminals.
16 F reedom HF Installation Guide Basic Installation Procedures A C Input Connections for the Freedom HF 1000, Freedom HF 1055, and Freedom HF 1800 Models 1. Ensure AC and DC power sources are turned off. 2. Install the required circuit breaker in the AC distribution panel supplying AC power to the unit.
975-0395-01-01 17 Basic Installation Procedures This guide for use by qua lified installers only. A C Input Connections for the Freedom HF 1055 EMS and Freedom HF 1800 EMS Models 1. Ensure AC and DC power sources are turned off. 2. Connect the three-prong plug to an AC wall outlet.
18 F reedom HF Installation Guide Basic Installation Procedures Step 5: Connecting A C Output to an Existing A C Circuit Do not connect the Freedom HF to an AC branch circuit that has high- power consumption loads.
975-0395-01-01 19 Basic Installation Procedures This guide for use by qua lified installers only. A C Output Connections for the Freedom HF 1000, Freedom HF 1055, and Freedom HF 1800 models T o make a permanent connec ti on to existing AC wiring: 1. Ensure AC and DC power sources are turned off.
20 F reedom HF Installation Guide Basic Installation Procedures A C Output Connections for the Freedom HF 1055 EMS and Freedom HF 1800 EMS Models 1. Ensure AC and DC power sources are turned off. 2. Install the required circuit breake r in the inverter distribution panel receiving AC power from the inverter .
975-0395-01-01 21 Basic Installation Procedures This guide for use by qua lified installers only. Step 6: Connecting the DC Cables The following instructions only apply to the following models: Freedom HF 1000 , Freedom HF 1055 , Freedom HF 1800, and Freedom HF 1800 T .
22 F reedom HF Installation Guide Basic Installation Procedures T o make the DC connections Refer to Figure 5. 1. Make sure the inverter is off and no AC or DC is connected to the unit. 2. Remove the nuts and washers fro m the Freedom HF positive and negative DC terminals.
975-0395-01-01 23 Basic Installation Procedures This guide for use by qua lified installers only. 12. Before proceeding, double check that the cable you have just installed connects the positive DC te.
24 F reedom HF Installation Guide Basic Installation Procedures Anderson Connector s The Freedom HF 1055 EMS and 1800 EMS models are pre-wired with an Anderson 1 connector that atta ches to matching terminal connectors in certain trucks and vehicles.
975-0395-01-01 25 Basic Installation Procedures This guide for use by qua lified installers only. Inverter Ignition Control (F or Freedom HF 1000, 1055, 1800, and 1800 T) The Freedom HF can be wired to inhibi t inverter operation in the absence of a vehicle’ s (or vessel's) ignition control signal.
26 F reedom HF Installation Guide Basic Installation Procedures 5. Remove the DC wiring cover to e xpose the ignition control terminals of the DC wiring compartment. 6. Unscrew and remove the red jumper wire, using a flat screw driver, in between terminal A and terminal Ignitio n Control .
975-0395-01-01 27 Basic Installation Procedures This guide for use by qua lified installers only. 6. Strip the vehicle’ s ignition control wire and connect it to the middle terminal Ignition Co ntrol . NO TE : Do not make any external connections to terminal Disabled .
28 F reedom HF Installation Guide Basic Installation Procedures Step 7: Mounting the Display P anel The communications cable supplied with the display panel is 25 feet (7.62 meters) long. If you want to replace the cable with one that is shorter , use a high quality , six-wire te lephone extension cable.
975-0395-01-01 29 Basic Installation Procedures This guide for use by qua lified installers only. Step 8: T esting Y our Installation There are two tests to be performed. T he first test verifi es that the Freedom HF is inverting DC battery power an d delivering AC power to its outp u t.
30 F reedom HF Installation Guide Basic Installation Procedures T esting in Shore P ower Mode T o test the Freedom HF in shore power mode: ◆ W ith the appliance from the prev ious test still connected and operating, connect the shore power source. The Freedom HF transf ers the appli a nces to shore power .
975-0395-01-01 31 This guide for use by qua lified installers only. Drip Shield Installation (F or Marine Installations) The drip shield helps to protect the unit from dripping or splashing liquids, which will cause a shock hazard.
32 F reedom HF Installation Guide Drip Shield Installation (For Marine Installations) T o install the drip shields: 1. Gather the four screws needed to fa sten a single drip shield to a wall. 2. Locate an appropriate setting for the drip shields above the Freedom HF making sure you cover th e entire width o f the unit.
975-0395-01-01 33 This guide for use by qua lified installers only. Configuration Refer the Owner’ s Guide for instructio ns on configuring the battery type accepted by the unit and on adjusting di splay , alarm, and ch ar ging current settings. Freedom HF Install Guide.
34 F reedom HF Installation Guide Marine Installation Figure 1 illustrat es a typical marine installation wi th the following components: 1. AC power supplied from a shore power connector 2. An AC source panel that include s a Max 30A circuit breaker that supplies the Freedom HF 3.
975-0395-01-01 35 This guide for use by qua lified installers only. Specifications NO TE: Specifications are subject to change without prior notice. Physical Spec ifications Freedom HF 1000/1055 models Freedom HF 1800 models L × W × H 15.5” (393mm) × 9.
36 F reedom HF Installation Guide Specifications NO TE : These specificat ions re fer to inverter mode. DC Input Freedom HF 1000/1055 models Freedom HF 1800 models Operating voltage range for all models 10.5–15.5 VDC (low limit) 1 1.8–15.5 VDC (high limit) 10.
975-0395-01-01 37 Specifications This guide for use by qua lified installers only. NO TE : These specificat ions refer to charger mode. AC Input Freedom HF 1000/1055 models Freedom HF 1800 models Oper.
Freedom HF Install Guide.book Page 38 Thursday, November 24, 20 11 11:06 AM.
Freedom HF Install Guide.book Page i Thursday, November 24, 2011 1 1:06 AM.
975-0395-01-01 Printed in China Xantrex Technology USA Inc. 1 800 670 0707 Tel toll free 1 408 987 6030 Tel direct 1 800 994 7828 Fax toll free customerservice@xantrex.
デバイスXantrex Technology 806-1055-02 806-1840の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Xantrex Technology 806-1055-02 806-1840をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはXantrex Technology 806-1055-02 806-1840の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Xantrex Technology 806-1055-02 806-1840の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Xantrex Technology 806-1055-02 806-1840で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Xantrex Technology 806-1055-02 806-1840を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はXantrex Technology 806-1055-02 806-1840の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Xantrex Technology 806-1055-02 806-1840に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちXantrex Technology 806-1055-02 806-1840デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。