GT100E MS Combiner Box for Master/Slave Configur ation Owner’ s Manual.
.
GT100E MS Combiner Box for Master/Slave Configuration Owner’s Manual.
About Xantrex Xantrex T echnology Inc. is a worl d-leadin g supplier of advanced power electroni cs and controls with products from 50 watt mobile units to one MW utility-s cale systems for wi nd, solar , batteries, fuel cells, microturbines, and backup power applicati ons in bo th grid-connected and st and-alone systems.
iii About This Manual Purpose The purpose of this Owner ’ s Manual is to provide explanat ion s and procedures for installing and configur ing the G T 100E MS Combiner Box for Master/Slave Configuration.
About T his Manual iv 152602 Conventions Used The following co nventions are used in thi s guide. Related Information Y ou can find more information about Xantrex T echnology Inc.
v Important Safety Instructions 1. Before installing and using th e G T100E MS Combiner Box for Master/Slave Configuration, read all instructions and cautionary markings on the G T100E MS Co mbiner Box for Master/Slave Configuration, G T 100E Grid T ie Inverter , and all appropriate sections of this manual.
vi.
152602 vii Important Safety Instructions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - v 1 Introduction GT100E MS Combiner Box - - - - - - - - - - - - - - - - - - - - - - - - -.
viii.
152602 ix Figure 1-1 Configuration Diagram - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–4 Figure 2-1 GT100E MS Componenets - - - - - - - - - - - - - - - - - - - - - - - - - .
x.
1 Intr oduction Chapter 1 contains a description of the G T100E MS and lists the different operating states available with the G T100E MS Combiner Box.
Introduction 1–2 152602 GT100E MS Combiner Box The G T10 0E MS combiner box, when installed with dual G T100E s, allows the G T100E Master/Slave configuration to maximize energy production during periods of lo w irradiance.
Master/Slave Operation States 152602 1–3 If daily role reversal is on, then the configured slave is operational slave on odd days (Janua ry 1,3 ,5,...) and operational ma ster on even days (January 2,4,6,...). Master Unit The G T100E Master inverter will control the G T100E MS Combiner Box via a control cable.
Introduction 1–4 152602 shutdown. The Master inverter will disable the Slave inverter and close the contactor in the G T 10 0E MS Combiner Box. The Master inverter will go online.
2 Installation Chapter 2 contains procedures on how to mount the G T100E MS and make the cable connections..
Installation 2–2 152602 Equipment Required • Ratchet Handle • Extension • Metric socket set • Metric wrench set • Metric hex wrench set • T orque wrench with 0-150Nm minimum range • Phillips Screwdriver Unpacking the GT100E MS T o unpack the G T100E MS from the shipping pallet: 1.
Unpacking the GT100E MS 152602 2–3 Figure 2-1 GT100E MS Componenets Cable 1-152492-01 and 1-152493-01 Safety Cover M6 Mounting hardware GT100E MS interface assemblies and GT100E MS Combiner Box GT10.
Installation 2–4 152602 Mounting Instructions T o mount the MS100E combiner box onto a wall: 1. Install the 4 wall mounting brackets P/N 062-200 0-02 to the rear of the MS100E Combiner box, see Figure 2-2. 2. Anchor the G T100E MS combiner box to the wall using anchor bolts.
Cable Installation 152602 2–5 Cable Installation W ire Gauge and T or que Specifications The following torque specifications ar e to be used on all electrical interfaces made during installati on of the G T100E MS Combiner Box.
Installation 2–6 152602 MS100E Connections Use the following descriptions and figures to correctly identify access panels and rou te wiring. Input/Output Access P anels Install all the cable strain reliefs, cust omer supplied, needed for cable entry in both Access Panels, see Figure 2-3.
Cable Installation 152602 2–7 PV Array and GT100E Connections Figure 2-4 PV Array and GT100E Connections PV ARRAY #1 and GT100E #1 Connections PV ARRAY #2 and GT100E #2 Connections.
Installation 2–8 152602 T o make PV Array #1 and G T 100E #1 connections : 1. Route the PV Array #1 cables through the access pa nel and connect the cables to PV ARRA Y #1 PV(+) and PV(-) terminals, see Figure 2- 5.
Cable Installation 152602 2–9 T o make PV Array #2 and G T 100E #2 connections : 1. Route the G T100E #2 cables thr ough the access panel and connect the cables to G T 100E UNIT #2 PV(+) an d PV(-) terminals, see Figure 2- 6.
Installation 2–10 152602 GT100E MS Control P ower Cable T o make G T100E MS Control Power Cable connections: 1. Connect the G T100E MS com bin er bo x power cable assembl y P/N 1- 152492-01 from the G T100E #1 throug h the access panel and connect it to P1, see Figure 2-7.
Cable Installation 152602 2–11 MS100E Interface Asse mbly Installation for GT100E #1 Mounting Instructions The G T 100E MS Interface is located in the bottom right compartment of the G T100E.
Installation 2–12 152602 T o install the G T100E MS Inte rfac e Assembly: 1. Mount the M S100E Interface Asse mbly to the Customer Interface Rail using the 4 supp lied T orx screws P/N 1-152173-01.
Cable Installation 152602 2–13 T o install the MS100E Interface Assembly Cable: 1. Connect the MS100E Interface A ssembly cable J20 to the G T100E Option Panel P20, located at the bottom/rear of the cabinet, see Figure 2-10. T o install the MS100E Control Power and Interface Cable: 1.
Installation 2–14 152602 T o install the MS100E Interface Assembly for G T100E #2: 1. Repeat the MS100E Interface Assemb ly Instructions for G T100E for the second G T100E unit - G T100E #2. GT100E Unit Installation T o install the G T100E refer to the G T 100E Grid T ie Inverter Installation Manual (P/N 152364).
3 Configur ation Chapter 3 describes how to configure the G T100E MS for Master/Slave configuration..
Configuration 3–2 152602 Master/Slave Configuration The Master/Slave system can be c o nfigured through the Xantrex Solar GUI (Graphical User Inte rface) software, P/N 1-1 52577-01, or thro ugh the Operator Interface Panel. Establish remote or lo cal communication with the G T100E, us ing the Xantrex Solar GUI software.
Master/Slave Configuration 152602 3–3 T o set a unit up as the Slave Unit: 1. Click T ools > Inverter Data > Operational Configuration 2. Check the Config ured Master check box Today’s statu.
Configuration 3–4 152602 3. Click Send Configuration 4. V erify that the Present Inverter Da ta has the unit set as the Configured Slave unit. Refer to the GUI Help menu for complete conf iguration instructions.
152602 WA–1 W arranty and Product Information Limited W arranty 1.1 What does this warranty cover and how long does it l ast? This Limited W arranty is provided by Xantrex T ech nolo gy In c.
W arranty and Return WA–2 152602 1.4 What does this warranty not cover? This Limited W arranty does not cover normal wear and tear of the product or costs associated with replacing consumable items such as li ke air filter, fuses, arrestors etc.
W arranty and Return 152602 WA–3 1.7 Exclusion for Documentation W ithout limiting the generality of the fo rego ing, unless specifically agreed to by it in writing, Xantrex: a.
WA–4.
.
Xantrex Technology Inc. 1 800 670 0707 Tel toll free NA 1 360 925 5097 Tel direct 1 800 994 7828 Fax toll free NA 1 360 925 5143 Fax direct customerservice@xantrex.
デバイスXantrex Technology GT100Eの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Xantrex Technology GT100Eをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはXantrex Technology GT100Eの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Xantrex Technology GT100Eの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Xantrex Technology GT100Eで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Xantrex Technology GT100Eを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はXantrex Technology GT100Eの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Xantrex Technology GT100Eに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちXantrex Technology GT100Eデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。