YorkメーカーE4TS030 THRU 060の使用説明書/サービス説明書
ページ先へ移動 of 24
036-21342-002 Rev. E (0505) FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE ® TECHNICAL GUIDE STEAL TH SPLIT -SYSTEM HEAT PUMP 15 SEER MODELS: E4TS 030 THRU 060 (2.5 THRU 5 NOMINAL T ONS) Due to continuous produc t improvement, specifi c tions are subject to chan ge without notice.
036-21342-002 Rev. E (0505 ) 2 Unitary Products Group SYSTEM OPERA TION This heat pump model is equippe d with both Y orkGuard V heat pump control and TS compressor control. The interface control 6CF board is used to bypass the first stage of heat when the outdoor temperature falls below ce rtain tempera- tures.
036-21342-002 Rev. E (0505) Unitary Products Group 3 Physical and Electrical Dat a MODEL E4TS030 E4TS036 E4TS048 E4TS060 UNIT SUPPL Y VOL T AGE 208/230-1-60 NORMAL VOL T AGE RANGE 1 1. Rated in accordance with ARI S tandard 1 10, utilizaton range “A”.
036-21342-002 Rev. E (0505 ) 4 Unitary Products Group 1. Unit factory charge listed on the unit nameplate include s re frigerant for the condensor , the smallest evaporator and for 15 f eet of interconnecting line tubing. 2. V erify the TXV kit and the additional charge required for the s pecific evaporator coil in the system using the table above.
036-21342-002 Rev. E (0505) Unitary Products Group 5 COOLING CAP ACITY - V ariable S peed Air Handler UNIT MODEL N1VS AIR HANDLER COIL MODEL 1 1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number .
036-21342-002 Rev. E (0505 ) 6 Unitary Products Group E4TS036 P1XDB12V 17 G2F D046S17 1 690 20000 15200 14. 0 12.4 2 1220 35600 25800 10.8 P1XUB12V 17 G2FD046S17 1 660 19800 15000 14.0 12.5 2 1200 35400 25600 1 1.0 G1UA048S17 1 660 19800 15000 14. 0 12.
036-21342-002 Rev. E (0505) Unitary Products Group 7 E4TS048 P1XUC16V 21 G1UA060S21 1 880 23800 17600 14.0 12.6 2 1600 47000 33800 10.8 G1UA060S21 1 880 23800 17600 14.0 12.6 2 1600 47000 33800 10.8 P1DUC20V 21 G1UA060S21 1 900 24200 18000 14 .0 12.6 2 1610 47500 34200 10.
036-21342-002 Rev. E (0505 ) 8 Unitary Products Group HEA TING CAP ACITY - V ari able Spe ed Air Handler UNIT MODEL N1VS AIR HANDLER COIL MODEL 1 1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number .
036-21342-002 Rev. E (0505) Unitary Products Group 9 HEA TING CAP ACITY - V ariable Speed Furnace UNIT MODEL V ARIABLE SPEED FURNACE MODEL WC O I L M O D E L HEA TING ST AGE (# CYL) RA TED CFM NET MBH 1,2 HSPF 3 COP 4 @ 47 F 47 OD 17 OD E4TS030 P1XDB12V075 17 G2FD046S17 1 580 12800 - - 3.
036-21342-002 Rev. E (0505 ) 10 Unitary Products Group E4TS036 P1DUB16V080 17 G2FD046S17 1 650 17000 - - 3.54 2 650 31000 18400 8.0 3.30 2 1200 34600 20600 8.4 3.56 G1UA048S17 1 650 17200 - - 3.58 2 650 31400 18600 8.0 3.32 2 1200 35000 20800 8.4 3.58 G1F A048S17 1 650 17200 - - 3.
036-21342-002 Rev. E (0505) Unitary Products Group 11 E4TS036 P1XUC20V095 21 G1UA048S21 1 625 16600 - - 3.48 2 625 31800 18800 7.9 3.34 2 1200 35400 21000 8 .3 3.60 G1F A048S21 1 625 16600 - - 3.48 2 625 31800 18800 7.9 3.34 2 1200 35400 21000 8 .3 3.
036-21342-002 Rev. E (0505 ) 12 Unitary Products Group ACCESSORIES Refer to Price Manual for specific model numbers. TXV Kit - Factory specified and required for p roper unit per- formance.
036-21342-002 Rev. E (0505) Unitary Products Group 13 Multipliers for determining th e performance with other indoor sections . HIGH CFM LOW CFM NOTE: KW RA TING IS FO R OUTDOOR AND INDOOR UNITS.
036-21342-002 Rev. E (0505 ) 14 Unitary Products Group Multipliers for determining th e performance with other indoor sections . HIGH CFM NOTE: KW RA TING I S FOR OUTDOOR AND INDOOR UNITS.
036-21342-002 Rev. E (0505) Unitary Products Group 15 Multipliers for determining th e performance with other indoor sections . LOW CFM NOTE: KW RA TING IS FO R OUTDOOR AND INDOOR UNITS.
036-21342-002 Rev. E (0505 ) 16 Unitary Products Group Multipliers for determining th e performance with other indoor sections . HIGH CFM LOW CFM NOTE: KW RA TING I S FOR OUTDOOR AND INDOOR UNITS.
036-21342-002 Rev. E (0505) Unitary Products Group 17 Multipliers for determining th e performance with other indoor sections . HIGH CFM LOW CFM NOTE: KW RA TING IS FO R OUTDOOR AND INDOOR UNITS.
036-21342-002 Rev. E (0505 ) 18 Unitary Products Group For notes see Page 1 1. Multipliers for determining th e performance with other indoor sections .
036-21342-002 Rev. E (0505) Unitary Products Group 19 For notes see Page 1 1. Multipliers for determining th e performance with other indoor sections .
036-21342-002 Rev. E (0505 ) 20 Unitary Products Group For notes see Page 1 1. Multipliers for determining th e performance with other indoor sections .
036-21342-002 Rev. E (0505) Unitary Products Group 21 For notes see Page 1 1. Multipliers for determining th e performance with other indoor sections .
036-21342-002 Rev. E (0505 ) 22 Unitary Products Group For notes see Page 1 1. Multipliers for determining th e performance with other indoor sections .
036-21342-002 Rev. E (0505) Unitary Products Group 23 MA TCHING INDOOR COMPONENTS G1UA UPFLOW G2FD* MUL TI-POSITION (UPFLOW , HORIZONT AL AND DOWNFLOW) G1F A FULL CASED AIR HANDLERS - FOR NON-FURNACE .
Subject to change without notice. Printed in U .S.A. 036-21342-002 Rev. E (0505) Copyright © by Y ork International Corp. 2005. All rights reser ved. Supersedes: 036-21342-002 Rev .
デバイスYork E4TS030 THRU 060の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
York E4TS030 THRU 060をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはYork E4TS030 THRU 060の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。York E4TS030 THRU 060の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。York E4TS030 THRU 060で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
York E4TS030 THRU 060を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はYork E4TS030 THRU 060の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、York E4TS030 THRU 060に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちYork E4TS030 THRU 060デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。